This paper describes the Sweaty II humanoid adult size robot trying to qualify for the RoboCup 2018 adult size humanoid competition. Sweaty came 2nd in RoboCup 2017 adult size league. The main characteristics of Sweaty are described in the Team Description Paper 2017. The improvements that have been made or are planned to be implemented for RoboCup 2018 are described in this paper.
The PHOTOPUR project aims to develop a photocatalytic process as a type of AOPs (Advanced Oxidation Processes) for the elimination of plant protection products (PPP) of the cleaning water used to wash sprayers. At INES a PV based energy supply for the photocatalytic cleaning system was developed within the framework of two bachelor theses and assembled as a demonstration unit. Then the system was step by step extended with further process automation features and pushed to a remote operating device. The final system is now available as a mobile unit mounted on a lab table. The latest step was the photocatalytic reactor module which completed the first PHOTOPUR prototype. The system is actually undergoing an intensive testing phase with performance checks at the consortium partners. First results give an overview about the successful operation.
Encapsulant-free N.I.C.E. modules have strong ecological advantages compared to conventional laminated modules but suffer generally from lower electrical performance. Via long-term outdoor monitoring of fullsize industrial modules of both types with identical solar cells, we investigated if the performance difference remains constant over time and which parameters influence its value. After assessing about a full year’s data, two obvious levers for N.I.C.E. optimization are identified: The usage of textured glass and transparent adhesives on the module rear side. Also, the performance loss could be alleviated using tracking systems due to lower AOI values. Our measurements show additionally that N.I.C.E. module surfaces are in average about 2.5°C cooler compared to laminated modules. With these findings, we lay out a roadmap to reduce today’s LIV gap of about 5%rel by different optimizations.
In this paper we report on further success of our work to develop a multi-method energy optimization which works with a digital twin concept. The twin concept serves to replicate production processes of different kinds of production companies, including complex energy systems and test market interactions to then use them for model predictive optimizing. The presented work finally reports about the performed flexibility assessment leading to a flexibility audit with a list of measures and the impact of energy optimizations made related to interactions with the local power grid i.e., the exchange node of the low voltage distribution grid. The analysis and continuous exploration of flexibilities as well as the exchange with energy markets require a “guide” leading to continuous optimization with a further tool like the Flexibility Survey and Control Panel helping decision-making processes on the day-ahead horizon for real production plants or the investment planning to improve machinery, staff schedules and production
infrastructure.
Three real-lab trigeneration microgrids are investigated in non-residential environments (educational, office/administrational, companies/production) with a special focus on domain-specific load characteristics. For accurate load forecasting on such a local level, à priori information on scheduled events have been combined with statistical insight from historical load data (capturing information on not explicitly-known consumer behavior). The load forecasts are then used as data input for (predictive) energy management systems that are implemented in the trigeneration microgrids. In real-world applications, these energy management systems must especially be able to carry out a number of safety and maintenance operations on components such as the battery (e.g. gassing) or CHP unit (e.g. regular test runs). Therefore, energy management systems should combine heuristics with advanced predictive optimization methods. Reducing the effort in IT infrastructure the main and safety relevant management process steps are done on site using a Smart & Local Energy Controller (SLEC) assisted by locally measured signals or operator given information as default and external inputs for any advanced optimization. Heuristic aspects for local fine adjustment of energy flows are presented.
The twin concept is increasingly used for optimization tasks in the context of Industry 4.0 and digitization. The twin concept can also help small and medium-sized enterprises (SME) to exploit their energy flexibility potential and to achieve added value by appropriate energy marketing. At the same time, this use of flexibility helps to realize a climate-neutral energy supply with high shares of renewable energies. The digital twin reflects real production, power flows and market influences as a computer model, which makes it possible to simulate and optimize on-site interventions and interactions with the energy market without disturbing the real production processes. This paper describes the development of a generic model library that maps flexibility-relevant components and processes of SME, thus simplifying the creation of a digital twin. The paper also includes the development of an experimental twin consisting of SME hardware components and a PLC-based SCADA system. The experimental twin provides a laboratory environment in which the digital twin can be tested, further developed and demonstrated on a laboratory scale. Concrete implementations of such a digital twin and experimental twin are described as examples.