INES - Institut für nachhaltige Energiesysteme
Refine
Year of publication
Document Type
- Article (reviewed) (108)
- Conference Proceeding (59)
- Article (unreviewed) (21)
- Report (19)
- Part of a Book (11)
- Contribution to a Periodical (7)
- Book (6)
- Doctoral Thesis (4)
- Master's Thesis (4)
- Patent (4)
Conference Type
- Konferenzartikel (48)
- Konferenz-Abstract (10)
- Konferenz-Poster (1)
Keywords
- Lithiumbatterie (10)
- Energieversorgung (9)
- Haustechnik (9)
- Brennstoffzelle (7)
- Wärmepumpe (7)
- Fotovoltaik (6)
- Batterie (5)
- lithium-ion battery (5)
- Bauteil (4)
- Elektrochemie (4)
Institute
Open Access
- Open Access (112)
- Closed Access (67)
- Closed (24)
- Bronze (15)
- Diamond (13)
- Gold (13)
- Grün (6)
- Hybrid (3)
This paper provides a comprehensive overview of approaches to the determination of isocontours and isosurfaces from given data sets. Different algorithms are reported in the literature for this purpose, which originate from various application areas, such as computer graphics or medical imaging procedures. In all these applications, the challenge is to extract surfaces with a specific isovalue from a given characteristic, so called isosurfaces. These different application areas have given rise to solution approaches that all solve the problem of isocontouring in their own way. Based on the literature, the following four dominant methods can be identified: the marching cubes algorithms, the tessellation-based algorithms, the surface nets algorithms and the ray tracing algorithms. With regard to their application, it can be seen that the methods are mainly used in the fields of medical imaging, computer graphics and the visualization of simulation results. In our work, we provide a broad and compact overview of the common methods that are currently used in terms of isocontouring with respect to certain criteria and their individual limitations. In this context, we discuss the individual methods and identify possible future research directions in the field of isocontouring.
Batteries typically consist of multiple individual cells connected in series. Here we demonstrate single-cell state of charge (SOC) and state of health (SOH) diagnosis in a 24 V class lithium-ion battery. To this goal, we introduce and apply a novel, highly efficient algorithm based on a voltage-controlled model (VCM). The battery, consisting of eight single cells, is cycled over a duration of five months under a simple cycling protocol between 20 % and 100 % SOC. The cell-to-cell standard deviations obtained with the novel algorithm were 1.25 SOC-% and 1.07 SOH-% at beginning of cycling. A cell-averaged capacity loss of 9.9 % after five months cycling was observed. While the accuracy of single-cell SOC estimation was limited (probably owed to the flat voltage characteristics of the lithium iron phosphate, LFP, chemistry investigated here), single-cell SOH estimation showed a high accuracy (2.09 SOH-% mean absolute error compared to laboratory reference tests). Because the algorithm does not require observers, filters, or neural networks, it is computationally very efficient (three seconds analysis time for the complete data set consisting of eight cells with approx. 780.000 measurement points per cell).
Variable refrigerant flow (VRF) and variable air volume (VAV) systems are considered among the best heating, ventilation, and air conditioning systems (HVAC) thanks to their ability to provide cooling and heating in different thermal zones of the same building. As well as their ability to recover the heat rejected from spaces requiring cooling and reuse it to heat another space. Nevertheless, at the same time, these systems are considered one of the most energy-consuming systems in the building. So, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. This study aims to compare these two energy systems by conducting an energy model simulation of a real building under a semi-arid climate for cooling and heating periods. The developed building energy model (BEM) was validated and calibrated using measured and simulated indoor air temperature and energy consumption data. The study aims to evaluate the effect of these HVAC systems on energy consumption and the indoor thermal comfort of the building. The numerical model was based on the Energy Plus simulation engine. The approach used in this paper has allowed us to reach significant quantitative energy saving along with a high level of indoor thermal comfort by using the VRF system compared to the VAV system. The findings prove that the VRF system provides 46.18% of the annual total heating energy savings and 6.14% of the annual cooling and ventilation energy savings compared to the VAV system.
During pyrolysis, biomass is carbonised in the absence of oxygen to produce biochar with heat and/or electricity as co-products making pyrolysis one of the promising negative emission technologies to reach climate goals worldwide. This paper presents a simplified representation of pyrolysis and analyses the impact of this technology on the energy system. Results show that the use of pyrolysis can allow getting zero emissions with lower costs by making changes in the unit commitment of the power plants, e.g. conventional power plants are used differently, as the emissions will be compensated by biochar. Additionally, the process of pyrolysis can enhance the flexibility of energy systems, as it shows a correlation between the electricity generated by pyrolysis and the hydrogen installation capacity, being hydrogen used less when pyrolysis appears. The results indicate that pyrolysis, which is available on the market, integrates well into the energy system with a promising potential to sequester carbon.
A smart energy concept was designed and implemented for a cluster of 5 existing multi-family houses, which combines heat pumps, photovoltaic (PV) modules and combined heat and power units (CHP) to achieve energy- and cost-efficient operation. Measurement results of the first year of operation show that the local power generation by PV modules and CHP unit has a positive effect on the electrical self-sufficiency by reducing electricity import from the grid. In winter, when the CHP unit operates continuously for long periods, the entire electricity for the heat pump and 91 % of the total electricity demand of the neighborhood are supplied locally. In summer, only 53 % is generated within the neighborhood. The use of a specifically developed energy management system EMS is intended to further increase this share. CO2 emissions for heating and electricity of the neighborhood are evaluated and amount to 18.4 kg/(m2a). Compared to the previous energy system consisting of gas boilers (29.1 kg/(m2a)), savings of 37 % are achieved with electricity consumption from the grid being reduced by 65 %. In the second construction stage, an additional heat pump, CHP unit and PV modules will be added. The measurement results indicate that the final district energy system is likely to achieve the ambitious CO2 reduction goal of -50% and further increase the self-sufficiency of the district.
Der vorliegende Leitfaden entstand im Rahmen der wissenschaftlichen Querspange »LowEx-Bestand Analyse« des thematischen Projektverbunds »LowEx-Konzepte für die Wärmeversorgung von Mehrfamilien-Bestandsgebäuden (LowEx-Bestand)« zusammen. In diesem Verbund arbeiteten die drei Forschungsinstitute Fraunhofer ISE, KIT und Universität Freiburg (INATECH) mit Herstellern von Heizungs- und Lüftungstechnik und mit Unternehmen der Wohnungswirtschaft zusammen. Gemeinsam wurden Lösungen entwickelt, analysiert und demonstriert, die den effizienten Einsatz von Wärmepumpen, Wärmeübergabesystemen und Lüftungssystemen bei der energetischen Modernisierung von Mehrfamiliengebäuden zum Ziel haben.
In der Studie "Technisch-wissenschaftliche Analyse zur Energieeffizienz unterschiedlicher Trinkwasser-Erwärmungssysteme im Vergleich" im Auftrag der Viega GmbH & Co. KG werden verschiedene Trinkwasser-Erwärmungssysteme hinsichtlich ihrer Energieeffizienz in Wärmepumpensystemen vergleichend untersucht. Neben Aufbau und Parametrierung eines Simulationsmodells sowie Integration von Lastreihen nach Norm umfasst die Studie eine detaillierte Abbildung aller untersuchten Systeme. Dabei liegt ein Schwerpunkt auf der Einordnung des Energieeinsparpotenzials durch eine Warmwassertemperaturreduktion mit dem Viega AVS Trinkwasser Management System. Die untersuchten Varianten sind: Referenzsystem 1: Durchflusstrinkwassererwärmer DTE (1 stufig) mit Rücklaufeinschichtung. System 2: Viega DTE (2 stufig). System 3: Viega AVS Trinkwasser Management System mit DTE (2 stufig) und Ultrafiltrationsmodul im Zirkulationsrücklauf UFC. System 4: Wohnungsstation, 4-Leiter-System. System 5: Wohnungsstation, 2-Leiter-System. System 6: Elektrischer Durchlauferhitzer. Die Studie ergab, dass sich bei Einsatz einer Niedertemperatur-Wärmepumpe mit maximaler Vorlauftemperatur von 58 °C das Viega AVS System mit DTE und UFC, dezentrale elektrische Durchlauferhitzer sowie das 4-Leiter-System bei einer Trinkwassertemperatur von 45°C im Vergleich als energetisch am besten erweisen. Bei einer Wärmepumpe mit einer höheren maximalen Vorlauftemperatur von 64 °C kann auch das 4-Leiter-System bei einer Trinkwassertemperatur von 50°C sinnvoll eingesetzt werden. Die Ergebnisse zeigten auch, dass je höher die durch die Wärmepumpe bereitgestellte Temperatur (maximale Vorlauftemperatur), desto besser lassen sich auch die anderen Systeme einsetzen, da sich dadurch der Einsatz des Backup-Systems minimieren lässt. Das Viega Aqua VIP System mit Temperaturabsenkung schneidet im Vergleich sehr gut hinsichtlich des Einsatzes der Endenergie und der zu erreichenden Jahresarbeitszahl ab. Der Einsatz dieses Systems in Kombination mit einer Wärmepumpe bietet Potenzial für den Einsatz erneuerbarer Energien.
LowEx-Konzepte für die Wärmeversorgung von Mehrfamilien-Bestandsgebäuden ("LowEx-Bestand Analyse")
(2023)
Der vorliegende Abschlussbericht fasst die Ergebnisse der wissenschaftlichen Querspange »LowEx-Bestand Analyse« des thematischen Projektverbunds »LowEx-Konzepte für die Wärmeversorgung von Mehrfamilien-Bestandsgebäuden (LowEx-Bestand)« zusammen. In diesem Verbund arbeiteten drei Forschungsinstitute mit Herstellern von Heizungs- und Lüftungstechnik und mit Unternehmen der Wohnungswirtschaft zusammen. Gemeinsam wurden Lösungen entwickelt, analysiert und demonstriert, die den effizienten Einsatz von Wärmepumpen, Wärmeübergabesystemen und Lüftungssystemen bei der energetischen Modernisierung von Mehrfamiliengebäuden zum Ziel haben. LowEx-Systeme arbeiten durch geringe Temperaturdifferenzen zwischen Heizmedium und Nutzwärmebesonders effizient. Wärmepumpen haben dabei erhebliches Potenzial zur Absenkung der spezifischen CO2-Emissionen bei der Wärmebereitstellung. Für die energetische Modernisierung von Mehrfamiliengebäuden ist der Einsatz solcher Systeme mit besonderen Herausforderungen und Anforderungen an die Übergabe der Raumwärme, die Warmwasserbereitung und die Nutzung von Umweltwärme verbunden. Diese Herausforderungen werden in LowEx-Bestand adressiert.
Optimization of energetic refurbishment roadmaps for multi-family buildings utilizing heat pumps
(2023)
A novel methodology for calculating optimized refurbishment roadmaps is developed in this paper. The aim of the roadmaps is to determine when and how should which component of the building envelope and heat generation system be refurbished to achieve the lowest net present value. The integrated optimization approach couples a particle swarm optimization algorithm with a dynamic building simulation of the building envelope and the heat supply system. Due to a free selection of implementation times and refurbishment depth, the optimization method achieves the lowest net present value and high CO2 reduction and is therefore an important contribution to achieve climate neutrality in the building stock.
The method is exemplarily applied to a multi-family house built in 1970. In comparison to a standard refurbishment roadmap, cost savings of 6–16 % and CO2 savings of 6–59 % are possible. The sensitivity of the refurbishment roadmap measures is analyzed on the basis of a parametric analysis. Robust optimization results are obtained with a mean refurbishment level of approx. 50 kWh/m2/a of the building envelope. The preferred heat generation system is a bivalent brine-heat pump system with a share of 70 % of the heat load being covered by the electric heat pump.
Elektrische Wärmepumpen sind eine Schlüsseltechnologie für klimafreundliche Gebäude. In Mehrfamilienhäusern ist ihr Einsatz noch eine Herausforderung und entsprechend wenig verbreitet. Im Rahmen des Verbundprojekts "HEAVEN" haben Forschende nun ein Mehrquellen-Wärmepumpensystem entwickelt, das an die Anforderungen größerer Wohngebäude angepasst ist. Getestet wurde es im Rahmen des Verbundprojekts "Smartes Quartier Durlach" in einem Karlsruher Gebäude. Daten zum ersten Betriebsjahr liegen nun vor.
Diese Metadaten wurden zur Verfügung gestellt von der Literaturdatenbank RSWB®plus
Am 1. Juli 2022 trafen sich im Rahmen des Abschlusskolloquiums des Projekts ACA-Modes rund 60 Teilnehmende aus Forschung, Lehre und Industrie zu einer internationalen Konferenz an der Hochschule Offenburg. Hier wurden die Projektergebnisse rund um die erfolgreiche Implementierung modellprädiktiver Regelstrategien vorgestellt, aktuelle Fragestellungen diskutiert und Entwicklungspfade hin zu einem netzdienlichen Betrieb von Energieverbundsystemen skizziert.
Heat pumps play a central role in decarbonizing the heat supply of buildings. However, in this article, implementing heat pumps in existing buildings, a significant challenge is still presented due to high temperature requirements. In this article, a systematic analysis of the effects of heat source temperatures, maximum heat pump condenser temperatures, and system temperatures on the seasonal performance of heat pump (HP) systems is presented. The quantitative performance analysis encompasses over 50 heat pumps installed in residential buildings, revealing correlations between the building characteristics, observed temperatures, and heat pump type. The performance of an HP system retrofitted to a 30-dwelling multifamily building is presented in more detail. The bivalent HP system combines air and ground as heat sources and achieves a seasonal performance factor of 3.25 with a share of the gas boiler of 27% in its first year of operation. In these findings, the technical feasibility of retrofitting heat pumps is demonstrated in existing buildings and insights are provided into overcoming the challenges associated with high temperature requirements.
Wärmepumpen sind eine Schlüsseltechnologie der Wärmewende. Durch die Nutzbarmachung von Umweltwärme und den Antrieb mit Elektrizität, die zunehmend aus erneuerbaren Energien gewonnen wird, kann die CO2-Intensität der Wärmeversorgung gesenkt werden. Eine Herausforderung besteht in der Anwendung in größeren Mehrfamilienbestandsgebäuden. Lösungsansätze und beispielhafte Umsetzungen werden hierzu vorgestellt.
Lithium-ion batteries exhibit slow voltage dynamics on the minute time scale that are usually associated with transport processes. We present a novel modelling approach toward these dynamics by combining physical and data-driven models into a Grey-box model. We use neural networks, in particular neural ordinary differential equations. The physical structure of the Grey-box model is borrowed from the Fickian diffusion law, where the transport domain is discretized using finite volumes. Within this physical structure, unknown parameters (diffusion coefficient, diffusion length, discretization) and dependencies (state of charge, lithium concentration) are replaced by neural networks and learnable parameters. We perform model-to-model comparisons, using as training data (a) a Fickian diffusion process, (b) a Warburg element, and (c) a resistor-capacitor circuit. Voltage dynamics during constant-current operation and pulse tests as well as electrochemical impedance spectra are simulated. The slow dynamics of all three physical models in the order of ten to 30 min are well captured by the Grey-box model, demonstrating the flexibility of the present approach.
This article presents the development, parameterization, and experimental validation of a pseudo-three-dimensional (P3D) multiphysics aging model of a 500 mAh high-energy lithium-ion pouch cell with graphite negative electrode and lithium nickel manganese cobalt oxide (NMC) positive electrode. This model includes electrochemical reactions for solid electrolyte interphase (SEI) formation at the graphite negative electrode, lithium plating, and SEI formation on plated lithium. The thermodynamics of the aging reactions are modeled depending on temperature and ion concentration and the reactions kinetics are described with an Arrhenius-type rate law. Good agreement of model predictions with galvanostatic charge/discharge measurements and electrochemical impedance spectroscopy is observed over a wide range of operating conditions. The model allows to quantify capacity loss due to cycling near beginning-of-life as function of operating conditions and the visualization of aging colormaps as function of both temperature and C-rate (0.05 to 2 C charge and discharge, −20 °C to 60 °C). The model predictions are also qualitatively verified through voltage relaxation, cell expansion and cell cycling measurements. Based on this full model, six different aging indicators for determination of the limits of fast charging are derived from post-processing simulations of a reduced, pseudo-two-dimensional isothermal model without aging mechanisms. The most successful aging indicator, compared to results from the full model, is based on combined lithium plating and SEI kinetics calculated from battery states available in the reduced model. This methodology is applicable to standard pseudo-two-dimensional models available today both commercially and as open source.
Encapsulant-free N.I.C.E. modules have strong ecological advantages compared to conventional laminated modules but suffer generally from lower electrical performance. Via long-term outdoor monitoring of fullsize industrial modules of both types with identical solar cells, we investigated if the performance difference remains constant over time and which parameters influence its value. After assessing about a full year’s data, two obvious levers for N.I.C.E. optimization are identified: The usage of textured glass and transparent adhesives on the module rear side. Also, the performance loss could be alleviated using tracking systems due to lower AOI values. Our measurements show additionally that N.I.C.E. module surfaces are in average about 2.5°C cooler compared to laminated modules. With these findings, we lay out a roadmap to reduce today’s LIV gap of about 5%rel by different optimizations.
Wirtschaftlichkeitsbetrachtung eines smarten Energiekonzepts für ein Bestandsquartier in Karlsruhe
(2023)
Die Transformation der Energieversorgung in Bestandsgebäuden ist für die Erreichung der Klimaziele im Gebäudesektor entscheidend. In einem modellhaften Quartiersprojekt in Karlsruhe-Durlach wird ein ‚smartes Energiekonzept‘, bestehend aus Wärmepumpen, Blockheizkraftwerk und PV-Anlagen mit lokalem Strom- und Wärmenetz umgesetzt und messtechnisch begleitet. Ziel ist dabei eine CO2-effiziente und wirtschaftliche Bereitstellung von Wärme und Strom.
In dem Artikel wird eine Wirtschaftlichkeitsbetrachtung für das Wärme- und Stromcontracting auf Basis der realen Investitionskosten sowie der gemessenen und berechneten Energieflüsse durchgeführt. Die Wärmegestehungskosten hängen neben den Investitionskosten von den energiewirtschaftlichen Rahmenbedingungen ab. Mit ansteigender CO2-Steuer werden mittelfristig Wärmegestehungskosten erreicht, die unter denen konventioneller Energiesysteme liegen. Dadurch bietet das integrierte Energiekonzept ein breites Anwendungspotenzial für städtische Bestandsquartiere außerhalb von Fernwärme-Gebieten.
Soiling is an important issue in the renewable energy sector since it can result in significant yield losses, especially in regions with higher pollution or dust levels. To mitigate the impact of soiling on photovoltaic (PV) plants, it is essential to regularly monitor and clean the panels, as well as develop accurate soiling predictions that can affect cleaning strategies and enhance the overall performance of PV power plants. This research focuses on the problem of soiling loss in photovoltaic power plants and the potential to improve the accuracy of soiling predictions. The study examines how soiling can affect the efficiency and productivity of the modules and how to measure and predict soiling using machine learning (ML) algorithms. The research includes analyzing real data from large-scale ground-mounted PV sites and comparing different soiling measurement methods. It was observed that there were some deviations in the real soiling loss values compared to the expected values for some projects in southern Spain, thus, the main goal of this work is to develop machine learning models that could predict the soiling more accurately. The developed models have a low mean square error (MSE), indicating the accuracy and suitability of the models to predict the soiling rates. The study also investigates the impact of different cleaning strategies on the performance of PV power plants and provides a powerful application to predict both the soiling and the number of cleaning cycles.
Predictive control has great potential in the home energy management domain. However, such controls need reliable predictions of the system dynamics as well as energy consumption and generation, and the actual implementation in the real system is associated with many challenges. This paper presents the implementation of predictive controls for a heat pump with thermal storage in a real single-family house with a photovoltaic rooftop system. The predictive controls make use of a novel cloud camera-based short-term solar energy prediction and an intraday prediction system that includes additional data sources. In addition, machine learning methods were used to model the dynamics of the heating system and predict loads using extensive measured data. The results of the real and simulated operation will be presented.
Der prozentuale Energieaufwand für die Warmwasserbereitung ist umso höher, je geringer der Bedarf an Raumwärme – erreicht durch besser gedämmte Gebäudehüllen – ist. Gleichzeitig kann dieser Aufwand für Warmwasser aufgrund der normativ geforderten Systemtemperaturen von 60/55 °C bei zentraler Warmwasserbereitung über Wärmepumpen nur vergleichsweise energieaufwendig abgedeckt werden. Eine Studie des Fraunhofer ISE zeigt, wie groß dieser Temperatur-Effekt im Vergleich unterschiedlicher Trinkwasser-Erwärmungssysteme ist.
Photovoltaic-heat pump (PV-HP) combinations with battery and energy management systems are becoming increasingly popular due to their ability to increase the autarchy and utilization of self-generated PV electricity. This trend is driven by the ongoing electrification of the heating sector and the growing disparity between growing electricity costs and reducing feed-in tariffs in Germany. Smart control strategies can be employed to control and optimize the heat pump operation to achieve higher self-consumption of PV electricity. This work presents the evaluation results of a smart-grid ready controlled PV-HP-battery system in a single-family household in Germany, using 1-minute-high-resolution field measurement data. Within 12 months evaluation period, a self-consumption of 43% was determined. The solar fraction of the HP amounts to 36%, enabled also due to higher set temperatures for space heating and domestic hot water production. Accordingly, the SPF decreases by 4.0% the space heating and by 5.7% in the domestic hot water mode. The combined seasonal performance factor for the heat pump system increases from 4.2 to 6.7, when only considering the electricity taken from the grid and disregarding the locally generated electricity supplied from photovoltaic and battery units.
Photovoltaic thermal (PVT) technology has been drawing attention recently. Electrification of the heating sector with heat pumps run by carbon-free electricity sources like photovoltaics is setting the ground for the interest. This article gives insight into PVT technologies and collector designs according to application and operating temperatures. For most conventional designs, examples like prototypes from Research & Development projects are presented. In addition, commercial products are listed along these categories, and the influence on the gross thermal and electrical yield is depicted based on Solar Keymark certification data. The process of certification is presented in a comprehensive way, showing current limitations, giving an outlook on the most recent approach for enhanced procedures and specifications. Finally, different system layouts are presented, and examples from installations combined with a heat pump are given with their specific performances. Real performance data of several PVT installations are compared to conventional heat pump systems. The identified seasonal performance factors are in a range from 3.4 to 4.2 and in between air source and ground source heat pumps. Continuous monitoring and derived data are enablers to discover the decisive influence of the system layout and dimensioning on performance indicators like, for example, operating temperatures over the year.
With the function RooTri(), we present a simple and robust calculation method for the approximation of the intersection points of a scalar field given as an unstructured point cloud with a plane oriented arbitrarily in space. The point cloud is approximated to a surface consisting of triangles whose edges are used for computing the intersection points. The function contourc() of Matlab is taken as a reference. Our experiments show that the function contourc() produces outliers that deviate significantly from the defined nominal value, while the quality of the results produced by the function RooTri() increases with finer resolution of the examined grid.
In this paper we report on further success of our work to develop a multi-method energy optimization which works with a digital twin concept. The twin concept serves to replicate production processes of different kinds of production companies, including complex energy systems and test market interactions to then use them for model predictive optimizing. The presented work finally reports about the performed flexibility assessment leading to a flexibility audit with a list of measures and the impact of energy optimizations made related to interactions with the local power grid i.e., the exchange node of the low voltage distribution grid. The analysis and continuous exploration of flexibilities as well as the exchange with energy markets require a “guide” leading to continuous optimization with a further tool like the Flexibility Survey and Control Panel helping decision-making processes on the day-ahead horizon for real production plants or the investment planning to improve machinery, staff schedules and production
infrastructure.
To improve the building’s energy efficiency many parameters should be assessed considering the building envelope, energy loads, occupation, and HVAC systems. Fenestration is among the most important variables impacting residential building indoor temperatures. So, it is crucial to use the most optimal energy-efficient window glazing in buildings to reduce energy consumption and at the same time provide visual daylight comfort and thermal comfort. Many studies have focused on the improvement of building energy efficiency focusing on the building envelope or the heating, ventilation, and cooling systems. But just a few studies have focused on studying the effect of glazing on building energy consumption. Thus, this paper aims to study the influence of different glazing types on the building’s heating and cooling energy consumption. A real case study building located under a semi-arid climate was used. The building energy model has been conducted using the OpenStudio simulation engine. Building indoor temperature was calibrated using ASHRAE’s statistical indices. Then a comparative analysis was conducted using seven different types of windows including single, double, and triple glazing filled with air and argon. Tripleglazed and double-glazed windows with argon space offer 37% and 32% of annual energy savings. It should be stressed that the methodology developed in this paper could be useful for further studies to improve building energy efficiency using optimal window glazing.
Ziel der vorliegenden Arbeit ist das netzdienliche Betreiben einer Wärmepumpe. Um diese Netzdienlichkeit zu erreichen, wird ein modellprädiktiver Regler entwickelt und implementiert, dessen Ziel es ist die Stromkosten einer Wärmepumpe zu senken. Dazu werden die Variablen Stromkosten und ein simulierter Heizbetrieb betrachtet.
Die Entwicklung eines modellprädiktiven Reglers setzt zunächst eine Modellierung der Komponenten des Heizsystems voraus. Ebenfalls muss eine Kostenfunktion formuliert werden, die es zu minimieren gilt. In einem Optimierungsproblem werden die Modelle als Randbedingungen und die Kostenfunktion als Zielfunktion der Optimierung formuliert. Dazu müssen gewisse Vereinfachungen getroffen werden, um das Optimierungsproblem zuverlässig und ohne enormen Rechenaufwand in einer Regelungsschleife lösen zu können.
Nun wird das Optimierungsproblem mit externen Modulen verknüpft, die eine Kommunikation mit der realen Wärmepumpen, Strompreisprognosen und Wettervorhersagen ermöglichen. Der dabei entwickelte Algorithmus wird auf einem Raspberry Pi Einplatinencomputer gespeichert und dort in einem regelmäßigen Zeitintervall von 15 Minuten ausgeführt, um den Betrieb der Wärmepumpe zu regeln.
Schließlich wird der modellprädiktive Regler in Betrieb genommen. Anschließend kann der modellprädiktive Betrieb mit dem konventionellen Betrieb verglichen werden. Aus dem Vergleich wird deutlich, dass eine modellprädiktive Regelung tatsächlich die Netzdienlichkeit einer Wärmepumpe verbessern kann. Andererseits werden auch die Entwicklungspotentiale identifiziert.
This paper presents a framework for numerical building validation enhancement based on detailed building specifications from in-situ measurements and evidence-based validation assessment undertaken on a detached sustainable lightweight building in a semi-arid climate. The validation process has been undergone in a set of controlled experiments – a free-float period, and steady-state internal temperatures. The validation was conducted for a complete year with a 1-min time step for the hourly indoor temperature and the variable refrigerant flow (VRF) energy consumption. The initial baseline model was improved by three series of validation steps per three different field measurements including thermal transmittance, glazing thermal and optical properties, and airtightness. Then, the accurate and validated model was used for building energy efficiency assessment in 12 regions of Morocco. This study aims to assess the effect of accurate building characteristics values on the numerical model enhancement. The initial CV(RMSE) and NMBE have improved respectively from 14.58 % and −11.23 %–7.85 % and 1.86 % for the indoor temperature. Besides, from 31.17 % to 14.37 %–20.57 % and 9.77 % for energy consumption. The findings demonstrate that the lightweight construction with the use of a variable refrigerant flow system could be energy efficient in the southern regions of Morocco.
The variable refrigerant flow system is one of the best heating, ventilation, and air conditioning systems (HVAC) thanks to its ability to provide thermal comfort inside buildings. But, at the same time, these systems are considered one of the most energy-consuming systems in the building sector. Thus, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. Although many researchers have studied the optimization of the building energy performance considering heating or cooling needs, using air handling units, radiant floor heating, and direct expansion valves, few studies have considered the use of multi-objective optimization using only the thermostat setpoints of VRF systems for both cooling and heating needs. Thus, the main aim of this study is to conduct a sensitivity analysis and a multi-objective optimization strategy for a residential building containing a variable refrigerant flow system, to evaluate the effect of the building performance on energy consumption and improve the building energy efficiency. The numerical model was based on the EnergyPlus, jEPlus, and jEPlus+EA simulation engines. The approach used in this paper has allowed us to reach significant quantitative energy saving by varying the cooling and heating setpoints and scheduling scenarios. It should be stressed that this approach could be applied to several HVAC systems to reduce energy-building consumption.
Energy efficiency and hygrothermal performance of hemp clay walls for Moroccan residential buildings
(2023)
Hemp-based building envelopes have gained significant popularity in developed countries, and now the trend of constructing houses with hemp-clay blocks is spreading to developing countries like Morocco. Investigating the hygrothermal behavior of such structures under actual climate conditions is essential for advancing and promoting this sustainable practice. This paper presents an in-depth experimental characterization of a commercial hemp-clay brick that has been exposed to the outdoor environment for four years, in addition to field measurements on a building scale demonstration prototype. Additionally, the study simulates 17 representative cities to assess the hygrothermal performance and energy-saving potential in each of Morocco's six existing climate zones, using the EnergyPlus engine. The experimental campaign's findings demonstrate excellent indoor air temperature and relative humidity regulation within the hemp-clay wall building, leading to satisfactory levels of thermal comfort within hemp-clay wall buildings. This is attributed to the material's good thermal conductivity and excellent moisture buffering capacity (found to be 0.31 W/mK and 2.25 g/m2%RH), respectively). The energy simulation findings also point to significant energy savings, with cooling and heating energy reductions ranging from 27.7% to 47.5% and 33.7% to 79.8%, respectively, as compared to traditional Moroccan buildings.
Given the looming threats of climate change and the rapid worldwide urbanization, it is a necessity to prioritize the transition towards a carbon-free built environment. This research study provides a holistic digital methodology for parametric design of urban residential buildings with regard to the Mediterranean semi-arid climate zone of Morocco in the early design phase. The morphological parameters of the urban residential buildings, namely the buildings’ typology, the distance between buildings, the urban grid’s orientation, and the window-towall ratio, are evaluated in order to identify the key combinations of passive and active solar design strategies that determine the high energy performing configurations, based on the introduced Energy Performance Index (EPI), which is the ratio between solar BIPV production to maximum available installed BIPV capacity and the normalized thermal energy needs. Through an automated processing of 2187 iterations via Grasshopper, we simulate daylight autonomy, indoor thermal comfort and solar rooftop photovoltaic and building integrated photovoltaic (BIPV) energy potential. Then, we analyze the conflicting objectives of energy efficiency measures, active solar design strategies, and indoor visual comfort in the decision-making process that supports our goal of getting closer to net zero urban residential buildings. The digital workflow showed interesting trends in reaching a balanced equilibrium between performance metrics influenced by the contrasting impact of solar exposure on indoor daylight autonomy and thermal energy demand. Furthermore, the study’s findings indicate that it is possible to achieve an annual load match exceeding 66,56 % while simultaneously ensuring an acceptable visual indoor comfort (sDA higher than 0.4). The findings also highlight the important role of the BIPV system in shifting towards the net zero energy goal, by contributing up to 30 % of the overall solar energy output and covering up to 20 % of the yearly self-consumption. Moreover, the energy balance evaluation on an hourly basis indicates that BIPV system notably enhances the daily load cover factor by up to 5.5 %, particularly in the case of slab SN typology, throughout the different seasons. Graphical representations of the yearly, monthly and hourly load matches and the hourly energy balance of the best performing configurations provide a thorough understanding of the potential evolution of the urban energy system over time as a result of the gradual integration of active solar electricity production.
Lithium-ion battery cells exhibit a complex and nonlinear coupling of thermal, electrochemical,and mechanical behavior. In order to increase insight into these processes, we report the development of a pseudo-three-dimensional (P3D) thermo-electro-mechanical model of a commercial lithium-ion pouch cell with graphite negative electrode and lithium nickel cobalt aluminum oxide/lithium cobalt oxide blend positive electrode. Nonlinear molar volumes of the active materials as function of lithium stoichiometry are taken from literature and implemented into the open-source software Cantera for convenient coupling to battery simulation codes. The model is parameterized and validated using electrical, thermal and thickness measurements over a wide range of C-rates from 0.05 C to 10 C. The combined experimental and simulated analyses show that thickness change during cycling is dominated by intercalation-induced swelling of graphite, while swelling of the two blend components partially cancel each other. At C-rates above 2 C, electrochemistry-induced temperature increase significantly contributes to cell swelling due to thermal expansion. The thickness changes are nonlinearly distributed over the thickness of the electrode pair due to gradients in the local lithiation, which may accelerate local degradation. Remaining discrepancies between simulation and experiment at high C-rates might be attributed to lithium plating, which is not considered in the model at present.
A balcony photovoltaic (PV) system, also known as a micro-PV system, is a small PV system consisting of one or two solar modules with an output of 100–600 Wp and a corresponding inverter that uses standard plugs to feed the renewable energy into the house grid. In the present study we demonstrate the integration of a commercial lithium-ion battery into a commercial micro-PV system. We firstly show simulations over one year with one second time resolution which we use to assess the influence of battery and PV size on self-consumption, self-sufficiency and the annual cost savings. We then develop and operate experimental setups using two different architectures for integrating the battery into the micro-PV system. In the passive hybrid architecture, the battery is in parallel electrical connection to the PV module. In the active hybrid architecture, an additional DC-DC converter is used. Both architectures include measures to avoid maximum power point tracking of the battery by the module inverter. Resulting PV/battery/inverter systems with 300 Wp PV and 555 Wh battery were tested in continuous operation over three days under real solar irradiance conditions. Both architectures were able to maintain stable operation and demonstrate the shift of PV energy from the day into the night. System efficiencies were observed comparable to a reference system without battery. This study therefore demonstrates the feasibility of both active and passive coupling architectures.
Electrochemical pressure impedance spectroscopy (EPIS) is an emerging tool for the diagnosis of polymer electrolyte membrane fuel cells (PEMFC). It is based on analyzing the frequency response of the cell voltage with respect to an excitation of the gas-phase pressure. Several experimental studies in the past decade have shown the complexity of EPIS signals, and so far there is no agreement on the interpretation of EPIS features. The present study contributes to shed light into the physicochemical origin of EPIS features, by using a combination of pseudo-two-dimensional modeling and analytical interpretation. Using static simulations, the contributions of cathode equilibrium potential, cathode overpotential, and membrane resistance on the quasi-static EPIS response are quantified. Using model reduction, the EPIS responses of individual dynamic processes are predicted and compared to the response of the full model. We show that the EPIS signal of the PEMFC studied here is dominated by the humidifier. The signal is further analyzed by using transfer functions between various internal cell states and the outlet pressure excitation. We show that the EPIS response of the humidifier is caused by an oscillating oxygen molar fraction due to an oscillating mass flow rate.
The nonlinear behavior of inverters is largely impacted by the interlocking and switching times. A method for online identifying the switching times of semiconductors in inverters is presented in the following work. By being able to identify these times, it is possible to compensate for the nonlinear behavior, reduce interlocking time, and use the information for diagnostic purposes. The method is first theoretically derived by examining different inverter switching cases and determining potential identification possibilities. It is then modified to consider the entire module for more robust identification. The methodology, including limitations and boundary conditions, is investigated and a comparison of two methods of measurement acquisition is provided. Subsequently the developed hardware is described and the implementation in an FPGA is carried out. Finally, the results are presented, discussed, and potential challenges are encountered.
The present work describes an extension of current slope estimation for parameter estimation of permanent magnet synchronous machines operated at inverters. The area of operation for current slope estimation in the individual switching states of the inverter is limited due to measurement noise, bandwidth limitation of the current sensors and the commutation processes of the inverter's switching operations. Therefore, a minimum duration of each switching state is necessary, limiting the final area of operation of a robust current slope estimation. This paper presents an extension of existing current slope estimation algorithms resulting in a greater area of operation and a more robust estimation result.
Electrochemical pressure impedance spectroscopy (EPIS) has received the attention of researchers as a method to study mass transport processes in polymer electrolyte mem-brane fuel cells (PEMFC). It is based on analyzing the cell voltage response to a harmonic excitation of the gas phase pressure in the frequency domain. Several experiments with a single-cell fuel cell have shown that the spectra contain information in the frequency range typical for mass transport processes and are sensitive to specific operating condi-tions and structural fuel cell parameters. To further benefit from the observed features, it is essential to identify why they occur, which to date has not yet been accomplished. The aim of the present work, therefore, is to identify causal links between internal processes and the corresponding EPIS features.
To this end, the study follows a model-based approach, which allows the analysis of inter-nal states that are not experimentally accessible. The PEMFC model is a pseudo-2D model, which connects the mass transport along the gas channel with the mass transport through the membrane electrode assembly. A modeling novelty is the consideration of the gas vol-ume inside the humidifier upstream the fuel cell inlet, which proves to be crucial for the reproduction of EPIS. The PEMFC model is parametrized to a 100 cm² single cell of the French project partner, who provided the experimental EPIS results reproduced and in-terpreted in the present study.
The simulated EPIS results show a good agreement with the experiments at current den-sities ≤ 0.4 A cm–2, where they allow a further analysis of the observed features. At the lowest excitation frequency of 1 mHz, the dynamic cell voltage response approaches the static pressure-voltage response. In the simulated frequency range between 1 mHz – 100 Hz, the cell voltage oscillation is found to strongly correlate with the partial pressure oscillation of oxygen, whereas the influence of the water pressure is limited to the low frequency region.
The two prominent EPIS features, namely the strong increase of the cell voltage oscillation and the increase of phase shift with frequency, can be traced back via the oxygen pressure to the oscillation of the inlet flow rate. The phenomenon of the oscillating inlet flow rate is a consequence of the pressure change of the gas phase inside the humidifier and in-creases with frequency. This important finding enables the interpretation of experimen-tally observed EPIS trends for a variation of operational and structural fuel cell parame-ters by tracing them back to the influence of the oscillating inlet flow rate.
The separate simulation of the time-dependent processes of the PEMFC model through model reduction shows their individual influence on EPIS. The sluggish process of the wa-ter uptake by the membrane is visible below 0.1 Hz, while the charge and discharge of the double layer becomes visible above 1 Hz. The gas transport through the gas diffusion layer is only visible above 100 Hz. The simulation of the gas transport through the gas channel
without consideration of the humidifier becomes visible above 1 Hz. With consideration of the humidifier the gas transport through the gas channel is visible throughout the fre-quency range. The strong similarity of the spectra considering the humidifier with the spectra of the full model setup shows the dominant influence of the humidifier on EPIS.
A promising observation is the change in the amplitude relationship between the cell volt-age and the oxygen partial pressure oscillation as a function of the oxygen concentration in the catalyst layer. At a frequency where the influence of oxygen pressure on the cell voltage is dominant, for example at 1 Hz, the amplitude of the cell voltage oscillation could be used to indirectly measure the oxygen concentration in the catalyst layer.
Der verstärkte Einsatz von Wärmepumpen bei der Realisierung einer klimaneutralen Wärmeversorgung führt zu einer signifikanten Zunahme und Änderung der elektrischen Lasten in den Verteilnetzen. Daher gilt es, Wärmepumpen so zu steuern, dass sie Verteilnetze wenig belasten oder sogar unterstützen.
Inhalt des Projekts „PV²WP - PV Vorhersage für die netzdienliche Steuerung von Wärmepumpen“ (Projektlaufzeit 1.07.2018 – 30.06.2021) war die Demonstration eines neuen Ansatzes zur Steuerung von Heizungssystemen, die auf Wärmepumpen und thermischen Speichern basieren und in Kombination mit einer Photovoltaikanlage betrieben werden. Das übergeordnete Ziel war dabei die Verbesserung der Netzintegration und Smart-Grid-Tauglichkeit entsprechender Heizungssysteme durch eine kostengünstige Technologie bei gleichzeitiger Erhöhung der Wirtschaftlichkeit.
Dabei wurden drei zukunftsweisende Technologien in Kombination genutzt und demonstriert: wolkenkamerabasierte Kurzfristprognosen, prädiktive Steuerung und Regelung sowie machinelearning-basierte Systemmodellierung als Basis für die Optimierung. Als Demonstrationsumgebung diente mit dem Projekthaus Ulm ein real bewohntes Einfamilienhaus.Umweltforschung
Für Verkehrsunternehmen stellt die Erprobung neuer Technologien eine große Herausforderung dar.
Sowohl Wasserstoff-Busse als auch Batterie-Busse können ihren Beitrag zur Umstellung des ÖPNV auf emissionsfreie Mobilität leisten. Je nach Anwendungsmuster können sich beide Technologien gut ergänzen und zu einem volkswirtschaftlichen Optimum führen. Es gilt, die Technologien im realen Umfeld zu erproben, um praxisnahe Erfahrung zu sammeln und dabei Mitarbeiter auszubilden, ohne die Qualität des Betriebes zu gefährden. Bei der aktuellen Kostenlage sehen beide Technologien ihre Einführung in den Betrieb mit Mehrkosten im Vergleich zu der aktuellen Diesel-Lösung verbunden.
Bei einer Batterie-basierten Lösung mit Pantograph-Schnellladung sind kürzere Linien gute Kandidaten für eine elektrische Umstellung ohne Auswirkungen auf die Größe der Busflotte. Auch Liniensysteme beliebiger Länge mit Knotenpunkten in regelmäßigen Abständen ermöglichen eine gemeinsame Nutzung der Ladeinfrastruktur und stellen somit reduzierte Aufbaukosten der Ladeinfrastruktur in Aussicht. In diesem Fall sind aber auch Fahrplanmanagement-Aspekte hinsichtlich der Ladezeit am Pantograph mit zu berücksichtigen, die nicht Bestandteil dieser Studie gewesen sind. Allgemein lassen die Kosten-Prognosen für Batterie und Batterie-elektrische Fahrzeuge eine signifikante Kostenreduzierung bis 2030 erkennen, die in manchen Konfigurationen zur Kostenparität und sogar geringeren Kosten als mit der Diesel-Variante führen würde.
Anders als für Batterie-Busse stellt die Linien-Konfiguration keinen wirtschaftlichen Einflussfaktor auf den Betrieb von Wasserstoff-Bussen dar. Die derzeitige Reichweite der H2-Busse reicht aus, um die zu erwartende tägliche Fahrleistung zu decken. Bei der Wasserstoffmobilität sind aber die Versorgungsinfrastruktur und die damit verbundenen Kraftstoffkosten von entscheidender Bedeutung. Ihr Aufbau ist mit hohen Investitionskosten und gesetzlichen Verpflichtungen verbunden (BImSchG, BetrSichV), die für eine erste Erprobung der Technologie im kleinen Maßstab eine Hürde für Verkehrsunternehmen darstellen könnte. Die H2 Mobility Deutschland bietet die Möglichkeit an, 700 bar Tankstellen mit einem 350 bar Modul zu erweitern, das die tägliche Versorgung von ca. 6 Bussen ermöglicht. Mit begrenzten Risiken für die Verkehrsunternehmen bietet es sich daher an, die H2 Mobilität auf eine limitierte Busflotte zu erproben. Da der Aufbau des H2-Mobility Deutschland Tankstellennetzes eine Lücke in Offenburg und Umgebung aufweist, wäre es vorstellbar, an der Errichtung einer solchen Tankstelle zu arbeiten, die die Betankung und Erprobung von Wasserstoff-Bussen ermöglicht. Auf längerer Sicht ist die Sicherstellung einer gut platzierten zuverlässigen und nachhaltigen Wasserstoffquelle von entscheidender Bedeutung. Derzeit liegen vorhandene Wasserstoffquellen in mehr als 100 km Entfernung. Eine Nutzung der Wasserkraft des naheliegenden Rheins erscheint durchaus sinnvoll, sowohl aus wirtschaftlichen als auch aus umwelttechnischen Gründen (erneuerbarer Strom, Stromkostenreduzierung durch Eigenversorgung, kürzere Transportwege, möglicher Nutzen für die Eurometropole Straßburg).
Es lässt sich festhalten, dass für die Region Offenburg zunächst die Erprobung beider Technologien, der Elektromobilität als auch der Wasserstoffmobilität, empfohlen wird. Es sollte zeitnah in den Erfahrungsaufbau in beide Technologien investiert werden. Zudem sollte bei der Elektromobilität das Flottenmanagement untersucht und evaluiert werden und bei der Wasserstoffmobilität die Möglichkeiten der Kooperation für den Aufbau der Wasserstofftankstelle. Im Rahmen der nächsten Ausschreibungsrunde für den öffentlichen Nahverkehr in Offenburg wird empfohlen, diesen emissionsfrei auszuschreiben. Es ist absehbar, dass aus Kostengründen (Kostenparität der Elektromobilität mit der Dieselvariante) als auch aus Gründen der Anforderung bzgl. der Emissionsgrenzwerte der ÖPNV emissionsfrei umgesetzt werden sollte.
Mit dem Klimaschutzgesetz 2021 wurden von der Bundesregierung die Klimaschutzvorgaben verschärft und die Treibhausgasneutralität bis 2045 als Ziel verankert. Zur Erreichung dieses ambitionierten Ziels ist es notwendig, im Bereich der Mobilität weitgehend von Verbrennungsmotoren mit fossilen Kraftstoffen auf Elektromobilität mit regenerativ erzeugtem Strom umzusteigen. Dabei ist die zügige Bereitstellung einer ausreichenden Ladeinfrastruktur für die Elektrofahrzeuge eine große Herausforderung. Neben der Installation einer ausreichend großen Zahl von Ladepunkten selbst besteht die Herausforderung darin, diese in das bestehende Verteilungsnetz zu integrieren bzw. das Verteilungsnetz so auszubauen, dass weiter ein sicherer Netzbetrieb gewährleistet werden kann. Dabei sind insbesondere Lösungen gefragt, bei denen der Ausbau der Ladeinfrastruktur und der Netzbetriebsmittel durch intelligentes Management des Ladens so gering wie möglich gehalten wird, indem vorhandene oder neu zu installierender Hardware möglichst effizient genutzt wird.
Hier setzte das Projekt „Intelligente Ladeinfrastruktur für Elektrofahrzeuge auf dem Parkplatz der Hochschule Offenburg (INTLOG)“ (Projektlaufzeit 15.11.2020 – 30.09.2022) an. Inhalt des Projekts war es, einen Ladepark für den Parkplatz der Hochschule Offenburg mit 20 Ladepunkten à 11 kW und somit einer Gesamtladeleistung von 220 kW an einen vorhandenen Ortsnetztransformator mit 200 kW Nennleistung anzuschließen, der aber bereits von anderen Verbrauchern genutzt wurde. Das übergeordnete Ziel war es also, eine Ladeinfrastruktur von maßgeblichem Umfang in die bestehende Netzinfrastruktur ohne zusätzlichen Ausbau zu integrieren.
Dabei wurden zukunftsweisende Technologien genutzt und weiterentwickelt sowie teilweise in Praxis, im Labor und in der Computersimulation demonstriert.
Im vorliegenden Beitrag wird ein Strommarktsimulationsmodell entwickelt, mit dessen Hilfe die Bereitstellung von Flexibilität auf dem Strom- und Regelleistungsmarkt in Deutschland modell-gestützt analysiert werden soll. Das Modell bildet dabei zwei parallel verlaufende, zentrale Wettbewerbsmärkte ab, an denen Akteure durch die individuelle Gebotsermittlung handeln können. Die entsprechend hierzu entwickelte Gebotslogik wird detailliert erläutert, wobei der Fokus auf der Flexibilität fossil-thermischer Kraftwerke liegt. In der anschließenden Gegen-überstellung mit realen Marktpreisen zeigt sich, dass die verwendete Methodik und die Ge-botslogik den bestehenden Markt und dessen Marktergebnis in geeigneter Form wiederspie-geln, wodurch zukünftig unterschiedlichste Flexibilitätsszenarien analysiert und Aussagen zu deren Auswirkungen auf den Markt und seine Akteure getroffen werden können.
Das Konzept der Thermoaktiven Bauteilsysteme (TABS) zur Heizung und Kühlung von Gebäuden gewinnt aufgrund seiner Kompatibilität mit erneuerbaren Energiequellen an Popularität. Die Steuerung von TABS und somit auch die Gewährleistung eines behaglichen Raumklimas erweist sich allerdings aufgrund der hohen Systemträgheit als komplex. Kurzfristige Witterungsänderungen sorgen für unerwünschte Raumtemperaturänderungen, die nur langsam korrigiert werden können. Bei Nichtwohngebäuden wie dem Regionalen Innovationszentrum für Energie (RIZ Energie) in Offenburg wird dieser Umstand durch die unregelmäßige Gebäudenutzung zusätzlich erschwert, da innere Wärmelasten stark variieren und nicht vorhersehbar sind.
Konventionelle TABS-Steuerungen können Störgrößen im TABS-Betrieb nur bedingt und zeitverzögert berücksichtigen, weswegen eine dauerhafte Gewährleistung des thermischen Komforts im Gebäude oft nicht erreichbar ist – dies ist auch am RIZ Energie der Fall. Als Lösung dient der Einsatz prädiktiver Steuerungsalgorithmen, die Störgrößen prognostizieren und den TABS-Betrieb dementsprechend anpassen können.
Diese Arbeit überprüft das Potenzial von intelligenten TABS-Steuerungsalgorithmen für den Einsatz am RIZ Energie anhand der Umsetzung mit einem digitalen Zwilling des Gebäudes. Dabei konnte unter Verwendung der Algorithmen und Berücksichtigung von inneren und äußeren Störgrößen im TABS-Betrieb ein verbessertes Raumklima simuliert werden. Infolgedessen konnte zudem der digitale Zwilling optimiert werden.
Decarbonisation Strategies in Energy Systems Modelling: Biochar as a Carbon Capture Technology
(2022)
The energy system is changing since some years in order to achieve the climate goals from the Paris Agreement which wants to prevent an increase of the global temperature above 2 °C. Decarbonisation of the energy system has become for governments a big challenge and different strategies are being stablished. Germany has set greenhouse gas reduction limits for different years and keeps track of the improvement made yearly. The expansion of renewable energy systems (RES) together with decarbonisation technologies are a key factor to accomplish this objective.
This research is done to analyse the effect of introducing biochar, a decarbonisation technology, and study how it will affect the energy system. Pyrolysis is the process from which biochar is obtained and it is modelled in an open-source energy system model. A sensibility analysis is made in order to assess the effect of changing the biomass potential and the costs for pyrolysis.
The role of pyrolysis is analysed in the form of different future scenarios to evaluate the impact. The CO2 emission limits from the years 2030 and 2045 are considered to create the scenarios, as well as the integration of flexibility technologies. Four scenarios in total are assessed and the result from the sensibility analysis considering pyrolysis are always compared to the reference scenario, where pyrolysis is not considered.
Results show that pyrolysis has a bigger impact in the energy system when the CO2 limit is low. Biochar can be used to compensate the emissions from other conventional power plant and achieve an energy transition with lower costs. Furthermore, it was also found that pyrolysis can also reduce the need of flexibility. This study also shows that the biomass potential and the pyrolysis costs can affect a lot the behaviour of pyrolysis in the energy system.
Global energy demand is still on an increase during the last decade, with a lot of impact on the climate change due to the intensive use of conventional fossil-based fuels power plants to cover this demand. Most recently, leaders of the globe met in 2015 to come out with the Paris Agreement, stating that the countries will start to take a more responsible and effective behaviour toward the global warming and climate change issues. Many studies have discussed how the future energy system will look like with respecting the countries’ targets and limits of greenhouse gases and their CO2 emissions. However, these studies rarely discussed the industry sector in detail even though it is one of the major role players in the energy sector. Moreover, many studies have simulated and modelled the energy system with huge jumps of intervals in terms of years and environmental goals. In the first part of this study, a model will be developed for the German electrical grid with high spatial and temporal resolutions and different scenarios of it will be analysed meticulously on shorter periods (annual optimization), with different flexibilities and used technologies and degrees of innovations within each scenario. Moreover, the challenge in this research is to adequately map the diverse and different characteristics of the medium-sized industrial sector. In order to be able to take a first step in assessing the relevance of the industrial sector in Germany for climate protection goals, the industrial sector will be mapped in PyPSA-Eur (an open-source model data set of the European energy system at the level of the transmission network) by detailing the demand for different types of industry and assigning flexibilities to the industrial types. Synthetically generated load profiles of various industrial types are available. Flexibilities in the industrial sector are described by the project partner Fraunhofer IPA in the GaIN project and can be used. Using a scenario analysis, the development of the industrial sector and the use of flexibilities are then to be assessed quantitatively.
Significant improvements in module performance are possible via implementation of multi-wire electrodes. This is economically sound as long as the mechanical yield of the production is maintained. While flat ribbons have a relatively large contact area to exert forces onto the solar cell, wires with round cross section reduce this contact area considerably – in theory to an infinitively thin line. Therefore, the local stresses induced by the electrodes might increase to a point that mechanical production yields suffer unacceptably.
In this paper, we assess this issue by an analytical mechanical model as well as experiments with an encapsulant-free N.I.C.E. test setup. From these, we can derive estimations for the relationship between lay-up accuracy and expected breakage losses. This paves the way for cost-optimized choices of handling equipment in industrial N.I.C.E.-wire production lines.
Micronization of biochar (BC) may ease its application in agriculture. For example, fine biochar powders can be applied as suspensions via drip-irrigation systems or can be used to produce grnulated fertilizers. However, micronization may effect important physical biochar properties like the water holding capacity (WHC) or the porosity.
Dort, wo Modelle der operativen Energiesystemanalyse untereinander Überschneidungen aufweisen, stellt sich zunächst die Frage, ob sie bei gleichgearteten Fragestellungen auch die gleichen Antworten liefern. Dies zu beantworten war erstes Ziel des hier beschriebenen Vorhabens. Das zweite Ziel war, im Falle von Differenzen zu ermitteln, worin diese begründet liegen. Es waren nicht nur die Modelle selbst, sondern auch das methodische Vorgehen zur Modellerstellung und Simulation in Betracht zu ziehen. Die darauf aufbauende Identifikation von individuellen Optimierungspotenzialen war das dritte Ziel. Da die operative Energiesystemanalyse noch ein recht junger Forschungsbereich ist, existiert darüber hinaus Klärungsbedarf, welches Modell sich für welche Untersuchungen besonders eignet und welches methodische Vorgehen sich empfiehlt. Die Beantwortung dieser Fragen stellte das vierte Ziel des Vorhabens dar.
With recent developments in the Ukrainian-Russian conflict, many are discussing about Germany’s dependency on fossil fuel imports in its energy system, and how can the country proceed with reducing that dependency. With its wide-ranging consumption sectors, the electricity sector comes as the perfect choice to start with. Recent reports showed that the German federal government is already intending to have a fully renewable electricity by 2035 while exploiting all possible clean power options. This was published in the federal government’s climate emergency program (Easter Package) in early 2022. The aim of this package is to initiate a rapid transition and decarbonization of the electricity sector. The Easter Package expects an enormous growth of renewable energies to a completely new level, with already at least 80% renewable gross energy consumption, with extensive and broad deployment of different generation technologies on various scales. This paper will discuss this ambitious plan and outline some insights into this huge and rapidly increasing step, and show how much will Germany need in order to achieve this huge milestone towards a fully green supply of the electricity sector. Different scenarios and shares of renewables will be investigated in order to elaborate on preponed climate-neutral goal of the electricity sector by 2035. The results pointed out some promising aspects in achieving a 100% renewable power, with massive investments in both generation and storage technologies.