Unterschiedliche Stimulationszeitpunkte bei bimodaler Versorgung mit Hörgerät und Cochleaimplantat
(2023)
Die bimodale Versorgung von Patienten mit Hörgerät (HG) ipsilateral und Cochleaimplantat (CI) kontralateral bei asymmetrischem Hörverlust ist aufgrund vieler inhärenter Variablen die komplizierteste Versorgungsart im Kontext der Versorgung mit CI. Im vorliegenden Übersichtsartikel werden alle systematischen interauralen Unterschiede zwischen elektrischer und akustischer Stimulation dargestellt, die bei dieser Versorgungsart auftreten können. Darüber hinaus werden Methoden zur Quantifizierung des interauralen Latenzoffsets, also des Zeitunterschieds zwischen der akustischen und elektrischen Stimulation des Hörnervs, mittels Registrierung auditorisch evozierter Potenziale – erzeugt durch akustische bzw. elektrische Stimulation – und Messungen an den Sprachprozessoren und Hörgeräten vorgestellt. Die technische Kompensation des interauralen Latenzoffsets und ihre positive Auswirkung auf die Schalllokalisationsfähigkeit bimodal mit CI und HG versorgter Patienten wird ebenfalls beschrieben. Zuletzt werden neueste Erkenntnisse diskutiert, die Gründe dafür aufzeigen, warum die Kompensation des interauralen Latenzoffsets das Sprachverstehen im Störgeräusch bei bimodal versorgten CI-/HG-Trägern nicht verbessert.
Introduction: Subjects with mild to moderate hearing loss today often receive hearing aids (HA) with open-fitting (OF). In OF, direct sound reaches the eardrums with minimal damping. Due to the required processing delay in digital HA, the amplified HA sound follows some milliseconds later. This process occurs in both ears symmetrically in bilateral HA provision and is likely to have no or minor detrimental effect on binaural hearing. However, the delayed and amplified sound are only present in one ear in cases of unilateral hearing loss provided with one HA. This processing alters interaural timing differences in the resulting ear signals.
Methods: In the present study, an experiment with normal-hearing subjects to investigate speech intelligibility in noise with direct and delayed sound was performed to mimic unilateral and bilateral HA provision with OF.
Results: The outcomes reveal that these delays affect speech reception thresholds (SRT) in the unilateral OF simulation when presenting speech and noise from different spatial directions. A significant decrease in the median SRT from –18.1 to –14.7 dB SNR is observed when typical HA processing delays are applied. On the other hand, SRT was independent of the delay between direct and delayed sound in the bilateral OF simulation.
Discussion: The significant effect emphasizes the development of rapid processing algorithms for unilateral HA provision.
eLetter zum Artikel "Condiciones neuropsi-quiátricas y probable causa de muerte de Maurice Ravel" von Gómez-Carvajal AM, Botero-Meneses JS, Palacios-Espinosa X und Palacios-Sánchez L., veröffentlicht in Iatreia 35(3), Seite 341-8 (DOI: https://doi.org/10.17533/udea.iatreia.154).
The new input method was developed for research acoustic localization, including real and virtual sound sources. For these types of research, the input method plays an important role in the investigation of the auditory localization of sound sources in the collection of valid and meaningful data. The input method using LED array is based on the localization test, which is already used in the acoustics laboratory of the Peter-Osypka-Institute. The current input method via tablet with continuous input surface generates a high inaccuracy and error variance compared to the usual discontinuous input. To minimize this type of error for future measurements, an alternative method will be implemented as part of this bachelor thesis. The methodology of the alternative input method is based on the use of a controllable LED array with rotary encoder and push button. For this, an angular range from -90° to 90° with a 1° angular resolution shall be realized. The LED-array enables a visual representation while localizing sound sources.
Die vorliegende Erfindung betrifft Vorrichtungen zum Überwachen und Optimieren einer zeitlichen Triggerstabilität einer extrakorporalen Kreislaufunterstützung sowie Steuer- und Regeleinheiten zur extrakorporalen Kreislaufunterstützung, umfassend eine solche Vorrichtung und entsprechende Verfahren. Entsprechend wird eine Vorrichtung (10) zum Überwachen einer zeitlichen Triggerstabilität einer extrakorporalen Kreislaufunterstützung vorgeschlagen, welche dazu eingerichtet ist, einen ersten Datensatz (14) einer Messung eines EKG-Signals eines unterstützten Patienten über einen vorgegebenen Zeitraum zu empfangen. Die Vorrichtung (10) umfasst eine Auswerteeinheit (16), welche dazu eingerichtet ist, mehrere R-Trigger (26) aus dem ersten Datensatz (14) zu bestimmen oder zu identifizieren, wobei die Auswerteeinheit (16) weiterhin dazu eingerichtet ist, einen zweiten Datensatz (20) mit ausgewerteten EKG-Signalen und mehreren R-Triggern (28) zu empfangen oder bereitzustellen und den zweiten Datensatz (20) selektiv auf dem ersten Datensatz (14) abzubilden. Die Vorrichtung ist weiterhin dazu eingerichtet, ein Signal (22) auszugeben, welches kennzeichnend für einen zeitlichen Abstand sukzessiver R-Trigger (26) aus dem ersten Datensatz (14) und darauf abgebildeten sukzessiven R-Trigger (28) aus dem zweiten Datensatz (20) ist.
Device and method for monitoring and optimising a temporal trigger stability (WO2023094554A1)
(2023)
The present invention relates to devices for monitoring and optimising a temporal trigger stability of an extracorporeal circulatory support means, and to open-loop and closed-loop control units for the extracorporeal circulatory support means comprising such a device, and to corresponding methods. A device (10) for monitoring a temporal trigger stability of an extracorporeal circulatory support means is accordingly proposed, which device is designed to receive a first dataset (14) of a measurement of an ECG signal of a supported patient over a predefined period of time. The device (10) comprises an evaluation unit (16), which is designed to determine or identify a plurality of R triggers (26) from the first dataset (14), wherein the evaluation unit (16) is also designed to receive or provide a second dataset (20) having evaluated ECG signals and a plurality of R triggers (28) and to selectively map the second dataset (20) on the first dataset (14). The device is also designed to emit a signal (22) that characterises a temporal gap between successive R triggers (26) from the first dataset (14) and successive R triggers (28) from the second dataset (20) which are mapped on the first dataset.