Refine
Document Type
- Conference Proceeding (9)
- Article (reviewed) (4)
- Article (unreviewed) (4)
- Book (2)
- Contribution to a Periodical (2)
- Part of a Book (1)
Conference Type
- Konferenzartikel (9)
Is part of the Bibliography
- yes (22) (remove)
Keywords
- Optik (3)
- Photonik (3)
- Radar (3)
- UWB radars (2)
- catheter ablation (2)
- imaging algorithms (2)
- medical imaging (2)
- microwave (2)
- scattering measurements (2)
- Angle of Arrival (1)
Institute
- IUAS - Institute for Unmanned Aerial Systems (22) (remove)
Open Access
- Closed (5)
- Closed Access (5)
- Open Access (4)
- Bronze (1)
A method for evaluating skin cancer detection based on millimeter-wave technologies is presented. For this purpose, the relative permittivities are calculated using the effective medium theory for the benign and cancerous lesion, considering the change in water content between them. These calculated relative permittivities are further used for the simulation and evaluation of skin cancer detection using a substrate-integrated waveguide probe. A difference in the simulated scattering parameters S 11 of up to 13dB between healthy and cancerous skin can be determined in the best-case.
In this study, an approach to a microwave-based radar system for the localization of objects has been proposed. This could be particularly useful in microwave imaging applications such as cardiac catheter detection. An experimental system is defined and realized with the selection of an appropriate antenna design. Hardware control functions and different imaging algorithms are implemented as well. The functionality of this measurement setup has been analyzed considering multiple testscenarios and it is proved to be capable of locating multiple objects as well as expanded objects.
Chronic insomnia is defined by difficulties in falling asleep, maintaining sleep, and early morning awakening, and is coupled with daytime consequences such as fatigue, attention deficits, and mood instability. These symptoms persist over a period of at least 3 months (Diagnostic and Statistical Manual 5 criteria). Chronic insomnia can be a symptom of many medical, neurological, and mental disorders. As a disorder, it incurs substantial health-care and occupational costs, and poses substantial risks for the development of cardiovascular and mental disorders, including cognitive deficits. Family and twin studies confirm that chronic insomnia can have a genetic component (heritability coefficients between 42% and 57%), whereas the investigation of autonomous and central nervous system parameters has identified hyperarousal as a final common pathway of the pathophysiology, implicating an imbalance of sleep–wake regulation consisting of either overactivity of the arousal systems, hypoactivity of the sleep-inducing systems, or both. Insomnia treatments include benzodiazepines, benzodiazepine-receptor agonists, and cognitive behavioural therapy. Treatments currently under investigation include transcranial magnetic or electrical brain stimulation, and novel methods to deliver psychological interventions.
We report the use of the Raman spectral information of the chemical compound toluene C7H8 as a reference on the analysis of laboratory-prepared and commercially acquired gasoline-ethanol blends. The rate behavior of the characteristic Raman lines of toluene and gasoline has enabled the approximated quantification of this additive in commercial gasoline-ethanol mixtures. This rate behavior has been obtained from the Raman spectra of gasoline-ethanol blends with different proportions of toluene.
All these Raman spectra have been collected by using a self-designed, frequency precise and low-cost Fourier-transform Raman spectrometer (FT-Raman spectrometer) prototype. This FT-Raman prototype has helped to accurately confirm the frequency position of the main characteristic Raman lines of toluene present on the different gasoline-ethanol samples analyzed at smaller proportions than those commonly found in commercial gasoline-ethanol blends. The frequency accuracy validation has been performed by analyzing the same set of toluene samples with two additional state-of-the-art commercial FT-Raman devices. Additionally, the spectral information has been contrasted, with highly-correlated coefficients as a result, with the values of the standard Raman spectrum of toluene.
In the brain-cell microenvironment, diffusion plays an important role: apart from delivering glucose and oxygen from the vascular system to brain cells, it also moves informational substances between cells. The brain is an extremely complex structure of interwoven, intercommunicating cells, but recent theoretical and experimental works showed that the classical laws of diffusion, cast in the framework of porous media theory, can deliver an accurate quantitative description of the way molecules are transported through this tissue. The mathematical modeling and the numerical simulations are successfully applied in the investigation of diffusion processes in tissues, replacing the costly laboratory investigations. Nevertheless, modeling must rely on highly accurate information regarding the main parameters (tortuosity, volume fraction) which characterize the tissue, obtained by structural and functional imaging. The usual techniques to measure the diffusion mechanism in brain tissue are the radiotracer method, the real time iontophoretic method and integrative optical imaging using fluorescence microscopy. A promising technique for obtaining the values for characteristic parameters of the transport equation is the direct optical investigation using optical fibers. The analysis of these parameters also reveals how the local geometry of the brain changes with time or under pathological conditions. This paper presents a set of computations concerning the mass transport inside the brain tissue, for different types of cells. By measuring the time evolution of the concentration profile of an injected substance and using suitable fitting procedures, the main parameters characterizing the tissue can be determined. This type of analysis could be an important tool in understanding the functional mechanisms of effective drug delivery in complex structures such as the brain tissue. It also offers possibilities to realize optical imaging methods for in vitro and in vivo measurements using optical fibers. The model also may help in radiotracer biomarker models for the understanding of the mechanism of action of new chemical entities.
This paper presents new measurements of a bronze cast from the right hand of the famous Italian violin virtuoso Nicolò Paganini (1782-1840). These are compared to anthropometric standard values. In addition, detailed dorsal and palmar views of the cast are shown. With a middle finger length of 75 mm, the palm width is 60 mm and the hand length 152 mm, which is significantly below the 5% percentile of today's standard values. Also the finger length index (0.55), the ratio of finger length to palm length (0.98) and the ratio of finger length to palm width (1.25) are significantly above normal limits. Hence, Paganini had abnormal hand measurements with a very small palm and relatively "long" fingers. This remarkable constellation, among others, could have been advantageous for his amazing skills as a violinist.
Member Lens
(2013)