Refine
Year of publication
- 2021 (74) (remove)
Document Type
- Article (reviewed) (74) (remove)
Is part of the Bibliography
- yes (74) (remove)
Keywords
- Corporate Governance (3)
- Blockchain (2)
- Götz von Berlichingen (2)
- Handprothese (2)
- Predictive maintenance (2)
- Surface acoustic waves (2)
- 3D CAD (1)
- 3D computer-aided design (1)
- 3D print (1)
- 3D printed (1)
Institute
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (31)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (28)
- POIM - Peter Osypka Institute of Medical Engineering (12)
- Fakultät Wirtschaft (W) (11)
- INES - Institut für nachhaltige Energiesysteme (9)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (7)
- Fakultät Medien (M) (ab 22.04.2021) (4)
- ACI - Affective and Cognitive Institute (2)
- WLRI - Work-Life Robotics Institute (2)
- Zentrale Einrichtungen (2)
Open Access
- Open Access (44)
- Closed Access (30)
Despite increasing budgets for social media activities and a wide variety of performance measurement possibilities, many companies do not measure the performance of their social media activities. Research shows that those companies that measure the performance of social media activities use incorrect, too few or inappropriate metrics. A central problem is that there is often an inadequate performance measurement process. This article presents a process that focuses on the objectives of social media activities. In phase one of this process, suitable metrics are selected and target values are defined based on these objectives. In phase two, data are collected and analysed. Finally, actions are defined. The developed process helps companies to measure the performance of their social media activities.
This article presents a comparative experimental study of the electrical, structural and chemical properties of large‐format, 180 Ah prismatic lithium iron phosphate (LFP)/graphite lithium‐ion battery cells from two different manufacturers. These cells are particularly used in the field of stationary energy storage such as home‐storage systems. The investigations include (1) cell‐to‐cell performance assessment, for which a total of 28 cells was tested from each manufacturer, (2) electrical charge/discharge characteristics at different currents and ambient temperatures, (3) internal cell geometries, components, and weight analysis after cell opening, (4) microstructural analysis of the electrodes via light microscopy and scanning electron microscopy, (5) chemical analysis of the electrode materials using energy‐dispersive X‐ray spectroscopy, and (6) mathematical analysis of the electrode balances. The combined results give a detailed and comparative insight into the cell characteristics, providing essential information needed for system integration. The study also provides complete and self‐consistent parameter sets for the use in cells models needed for performance prediction or state diagnosis.
Treadmills are essential to the study of human and animal locomotion as well as for applied diagnostics in both sports and medicine. The quantification of relevant biomechanical and physiological variables requires a precise regulation of treadmill belt velocity (TBV). Here, we present a novel method for time-efficient tracking of TBV using standard 3D motion capture technology. Further, we analyzed TBV fluctuations of four different treadmills as seven participants walked and ran at target speeds ranging from 1.0 to 4.5 m/s. Using the novel method, we show that TBV regulation differs between treadmill types, and that certain features of TBV regulation are affected by the subjects’ body mass and their locomotion speed. With higher body mass, the TBV reductions in the braking phase of stance became higher, even though this relationship differed between locomotion speeds and treadmill type (significant body mass × speed × treadmill type interaction). Average belt speeds varied between about 98 and 103% of the target speed. For three of the four treadmills, TBV reduction during the stance phase of running was more intense (> 5% target speed) and occurred earlier (before 50% of stance phase) unlike the typical overground center of mass velocity patterns reported in the literature. Overall, the results of this study emphasize the importance of monitoring TBV during locomotor research and applied diagnostics. We provide a novel method that is freely accessible on Matlab’s file exchange server (“getBeltVelocity.m”) allowing TBV tracking to become standard practice in locomotion research.
Governments have restricted public life during the COVID-19 pandemic, inter alia closing sports facilities and gyms. As regular exercise is essential for health, this study examined the effect of pandemic-related confinements on physical activity (PA) levels. A multinational survey was performed in 14 countries. Times spent in moderate-to-vigorous physical activity (MVPA) as well as in vigorous physical activity only (VPA) were assessed using the Nordic Physical Activity Questionnaire (short form). Data were obtained for leisure and occupational PA pre- and during restrictions. Compliance with PA guidelines was calculated based on the recommendations of the World Health Organization (WHO). In total, n = 13,503 respondents (39 ± 15 years, 59% females) were surveyed. Compared to pre-restrictions, overall self-reported PA declined by 41% (MVPA) and 42.2% (VPA). Reductions were higher for occupational vs. leisure time, young and old vs. middle-aged persons, previously more active vs. less active individuals, but similar between men and women. Compared to pre-pandemic, compliance with WHO guidelines decreased from 80.9% (95% CI: 80.3–81.7) to 62.5% (95% CI: 61.6–63.3). Results suggest PA levels have substantially decreased globally during the COVID-19 pandemic. Key stakeholders should consider strategies to mitigate loss in PA in order to preserve health during the pandemic.
The compliant nature of distal limb muscle-tendon units is traditionally considered suboptimal in explosive movements when positive joint work is required. However, during accelerative running, ankle joint net mechanical work is positive. Therefore, this study aims to investigate how plantar flexor muscle-tendon behavior is modulated during fast accelerations. Eleven female sprinters performed maximum sprint accelerations from starting blocks, while gastrocnemius muscle fascicle lengths were estimated using ultrasonography. We combined motion analysis and ground reaction force measurements to assess lower limb joint kinematics and kinetics, and to estimate gastrocnemius muscle-tendon unit length during the first two acceleration steps. Outcome variables were resampled to the stance phase and averaged across three to five trials. Relevant scalars were extracted and analyzed using one-sample and two-sample t-tests, and vector trajectories were compared using statistical parametric mapping. We found that an uncoupling of muscle fascicle behavior from muscle-tendon unit behavior is effectively used to produce net positive mechanical work at the joint during maximum sprint acceleration. Muscle fascicles shortened throughout the first and second steps, while shortening occurred earlier during the first step, where negative joint work was lower compared with the second step. Elastic strain energy may be stored during dorsiflexion after touchdown since fascicles did not lengthen at the same time to dissipate energy. Thus, net positive work generation is accommodated by the reuse of elastic strain energy along with positive gastrocnemius fascicle work. Our results show a mechanism of how muscles with high in-series compliance can contribute to net positive joint work.
Emerging applications in soft robotics, wearables, smart consumer products or IoT-devices benefit from soft materials, flexible substrates in conjunction with electronic functionality. Due to high production costs and conformity restrictions, rigid silicon technologies do not meet application requirements in these new domains. However, whenever signal processing becomes too comprehensive, silicon technology must be used for the high-performance computing unit. At the same time, designing everything in flexible or printed electronics using conventional digital logic is not feasible yet due to the limitations of printed technologies in terms of performance, power and integration density. We propose to rather use the strengths of neuromorphic computing architectures consisting in their homogeneous topologies, few building blocks and analog signal processing to be mapped to an inkjet-printed hardware architecture. It has remained a challenge to demonstrate non-linear elements besides weighted aggregation. We demonstrate in this work printed hardware building blocks such as inverter-based comprehensive weight representation and resistive crossbars as well as printed transistor-based activation functions. In addition, we present a learning algorithm developed to train the proposed printed NCS architecture based on specific requirements and constraints of the technology.
Introduction: The use of scaffolds in tissue engineering is becoming increasingly important as solutions need to be found to preserve human tissues such as bone or cartilage. Various factors, including cells, biomaterials, cell and tissue culture conditions, play a crucial role in tissue engineering. The in vivo environment of the cells exerts complex stimuli on the cells, thereby directly influencing cell behavior, including proliferation and differentiation. Therefore, to create suitable replacement or regeneration procedures for human tissues, the conditions of the cells’ natural environment should be well mimicked. Therefore, current research is trying to develop 3-dimensional scaffolds (scaffolds) that can elicit appropriate cellular responses and thus help the body regenerate or replace tissues. In this work, scaffolds were printed from the biomaterial polycaprolactone (PCL) on a 3D bioplotter. Biocompatibility testing was used to determine whether the printed scaffolds were suitable for use in tissue engineering.
Material and Methods: An Envisiontec 3D bioplotter was used to fabricate the scaffolds. For better cell-scaffold interaction, the printed polycaprolactone scaffolds were coated with type-I collagen. Three different cell types were then cultured on the scaffolds and various tests were used to investigate the biocompatibility of the scaffolds.
Results: Reproducible scaffolds could be printed from polycaprolactone. In addition, a coating process with collagen was developed, which significantly improved the cell-scaffold interaction. Biocompatibility tests showed that the PCL-collagen scaffolds are suitable for use with cells. The cells adhered to the surface of the scaffolds and as a result extensive cell growth was observed on the scaffolds. The inner part of the scaffolds, however, remained largely uninhabited. In the cytotoxicity studies, it was found that toxicity below 20% was present in some experimental runs. The determination of the compressive strength by means of the universal testing machine Z005 by ZWICK according to DIN EN ISO 604 of the scaffolds resulted in a value of 68.49 ± 0.47 MPa.
In recent years, both the Internet of Things (IoT) and blockchain technologies have been highly influential and revolutionary. IoT enables companies to embrace Industry 4.0, the Fourth Industrial Revolution, which benefits from communication and connectivity to reduce cost and to increase productivity through sensor-based autonomy. These automated systems can be further refined with smart contracts that are executed within a blockchain, thereby increasing transparency through continuous and indisputable logging. Ideally, the level of security for these IoT devices shall be very high, as they are specifically designed for this autonomous and networked environment. This paper discusses a use case of a company with legacy devices that wants to benefit from the features and functionality of blockchain technology. In particular, the implications of retrofit solutions are analyzed. The use of the BISS:4.0 platform is proposed as the underlying infrastructure. BISS:4.0 is
intended to integrate the blockchain technologies into existing enterprise environments. Furthermore, a security analysis of IoT and blockchain present attacks and countermeasures are presented that are identified and applied to the mentioned use case.
We present a video-densitometric high-performance thin-layer chromatography (HPTLC) quantification method for patulin in apple juice, developed in a vertical chamber from the starting point to a distance of 50 mm, using MTBE, n-pentane (9 + 5, v/v) as mobile phase. After separation the plate is sprayed with methyl-benzothiazolinone hydrazone hydrochloride monohydrate (MBTH) solution (40 mg in 20 mL methanol) and heated at 105 °C for 15 min. Patulin zones are transformed into yellow spots. The quantification is based on direct measurements using an inexpensive 48-bit flatbed scanner for color measurements (in red, green, and blue). Evaluation of the blue channel makes the measurements very specific. Quantification in fluorescence was also done by use of a 16-bit CCD-camera and UV-366 nm illumination as well as using a HPTLC DAD-scanner. For linearization the extended Kubelka–Munk expression for data transformation was used. The range of linearity covers more than two magnitudes and lies between 5 and 800 ng patulin. The extraction of 20 g apple juice and an extract application on plate up to 50 µL allows statistically defined checking the limit of detection (LOD) of 50 ng patulin per track, which is equivalent to 50 µg patulin per kg apple juice.
We present a densitometric quantification method for triclosan in toothpaste, separated by high-performance thin-layer chromatography (HPTLC) and using a 48-bit flatbed scanner as the detection system. The sample was band-wise applied to HPTLC plates (10 × 20 cm), with fluorescent dye, Merck, Germany (1.05554). The plates were developed in a vertical developing chamber with 20 min of chamber saturation over 70 mm, using n-heptane–methyl tert-butyl ether–acetic acid (92:8:0.1, V/V) as solvent. The RF value of triclosan is hRF = 22.4, and quantification is based on direct measurements using an inexpensive 48-bit flatbed scanner for color measurements (in red, green, and blue) after plate staining with 2,6-dichloroquinone-4-chloroimide (Gibbs' reagent). Evaluation of the red channel makes the measurements of triclosan very specific. For linearization, an extended Kubelka–Munk expression was used for data transformation. The range of linearity covers more than two orders of magnitude and is between 91 and 1000 ng. The separation method is inexpensive, fast and reliable.