Refine
Document Type
- Article (unreviewed) (31) (remove)
Language
- English (31) (remove)
Has Fulltext
- no (31) (remove)
Is part of the Bibliography
- yes (31) (remove)
Keywords
- Kommunikation (3)
- Aufzeichnung (2)
- Drahtloses lokales Netz (2)
- Intelligentes Stromnetz (2)
- Medizintechnik (2)
- Abtragung (1)
- Algorithmus (1)
- Antenne (1)
- Applikation (1)
- Benchmark (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (31) (remove)
Open Access
- Closed Access (6)
- Open Access (6)
The Raman spectra from the chemical compounds toluene and cyclohexane obtained using a Fourier Transform (FT)-Raman spectrometer prototype have been contrasted with the Raman spectra of these same materials collected with two different commercial FT-Raman devices. The FT-Raman spectrometer consist of a Michelson interferometer, a self-designed photon counter and a reference photo-detector. The evaluation methodology of the spectral information, contrary to the commercial devices that commonly use the zero-crossing method, is carried out by re-sampling the Raman scattering and by accurately extracting the optical path information of the Michelson interferometer. The FTRaman arrangement has been built using conventional parts without disregarding the spectral frequency precision that usually such a FTRaman instruments deliver. No additional complex hardware components or costly software modules have been included in this FT-Raman device. The main Raman lines from the spectra obtained with the three FT-Raman devices have been compared with the Raman lines from the standard Raman spectra of these two materials. The values obtained using the FT-Raman spectrometer prototype have shown a frequency accuracy comparable to that obtained with the commercial devices without facing the need for a large investment. Although the proposed FT-Raman prototype cannot be directly compared to the last generation of FT-Raman spectrometers from the commercial manufacturers, such a device could give an opportunity to users that require high frequency precision in their spectral analysis and are provided with rather scarce resources.
The communication technologies for automatic me-ter reading (smart metering) and for energy production and distribution networks (smart grid) have the potential to be one of the first really highly scaled machine-to-machine-(M2M)-applications. During the last years two very promising devel-opments around the wireless part of smart grid communication were initialized, which possibly have an impact on the markets far beyond Europe and far beyond energy automation. Besides the specifications of the Open Metering System (OMS) Group, the German Federal Office for Information Security (Bundesamt für Sicherheit in der Informationstechnik, BSI) has designed a protection profile (PP) and a technical directive (TR) for the communication unit of an intelligent measurement sys-tem (smart meter gateway), which were released in March 2013. This design uses state-of-the-art technologies and prescribes their implementation in real-life systems. At first sight the expenditures for the prescribed solutions seem to be significant. But in the long run, this path is inevitable and comes with strategic advantages.
Multi-agent systems are a subject of continuously increasing interest in applied technical sciences. Smart grids are one evolving field of application. Numerous smart grid projects with various interpretations of multi-agent systems as new control concept arose in the last decade. Although several theoretical definitions of the term ‘agent’ exist, there is a lack of practical understanding that might be improved by clearly distinguishing the agent technologies from other state-of-the-art control technologies. In this paper we clarify the differences between controllers, optimizers, learning systems, and agents. Further, we review most recent smart grid projects, and contrast their interpretations with our understanding of agents and multi-agent systems. We point out that multi-agent systems applied in the smart grid can add value when they are understood as fully distributed networks of control entities embedded in dynamic grid environments; able to operate in a cooperative manner and to automatically (re-)configure themselves.
Mice and rats make up 95% of all animals used in medical research and drug discovery and development. Monitoring of physiological functions such as ECG, blood pressure, and body temperature over the entire period of an experiment is often required. Restraining of the animals in order to obtain this data can cause great inconvenience. The use of telemetric systems solves this problem and provides more reliable results. However, these devices are mostly equipped with batteries, which limit the time of operation or they use passive power supplies, which affects the operating range. The semi-passive telemetric implant being presented is based on RFID technology and overcomes these obstacles. The device is inductively powered using the magnetic field of a common RFID reader device underneath the cage, but is also able to operate for several hours autonomously. Being independent from the battery capacity, it is possible to use the implant over a long period of time or to re-use the device several times in different animals, thus avoiding the disadvantages of existing systems and reducing the costs of purchase and refurbishment.