Refine
Year of publication
- 2023 (487)
- 2021 (436)
- 2022 (433)
- 2018 (347)
- 2020 (346)
- 2019 (343)
- 2017 (322)
- 2016 (306)
- 2015 (288)
- 2013 (236)
- 2014 (235)
- 2012 (194)
- 2011 (161)
- 2010 (139)
- 2009 (106)
- 2024 (62)
- 2008 (54)
- 2006 (40)
- 2007 (40)
- 2004 (39)
- 2005 (37)
- 2001 (26)
- 1995 (21)
- 2003 (19)
- 2002 (17)
- 2000 (14)
- 1990 (12)
- 1998 (12)
- 1993 (11)
- 1997 (11)
- 1994 (10)
- 1996 (10)
- 1991 (8)
- 1992 (8)
- 1999 (8)
- 1989 (5)
- 1986 (4)
- 1982 (3)
- 1988 (3)
- 1983 (2)
- 1987 (2)
- 1972 (1)
- 1977 (1)
- 1984 (1)
Document Type
- Conference Proceeding (1253)
- Article (reviewed) (687)
- Bachelor Thesis (604)
- Article (unreviewed) (566)
- Part of a Book (460)
- Contribution to a Periodical (287)
- Book (242)
- Master's Thesis (208)
- Other (142)
- Working Paper (105)
Conference Type
- Konferenzartikel (950)
- Konferenz-Abstract (156)
- Konferenzband (77)
- Sonstiges (42)
- Konferenz-Poster (32)
Language
- German (2867)
- English (1981)
- Other language (5)
- Russian (3)
- Multiple languages (2)
- French (1)
- Spanish (1)
Keywords
- Mikroelektronik (62)
- Digitalisierung (48)
- Marketing (47)
- Social Media (40)
- COVID-19 (37)
- E-Learning (35)
- RoboCup (33)
- Kommunikation (32)
- Künstliche Intelligenz (32)
- Dünnschichtchromatographie (29)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (1118)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (1103)
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (917)
- Fakultät Wirtschaft (W) (650)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (565)
- Fakultät Medien (M) (ab 22.04.2021) (384)
- INES - Institut für nachhaltige Energiesysteme (245)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (161)
- Zentrale Einrichtungen (81)
- IMLA - Institute for Machine Learning and Analytics (79)
Open Access
- Closed Access (1708)
- Open Access (1693)
- Closed (756)
- Bronze (345)
- Diamond (92)
- Gold (77)
- Hybrid (50)
- Grün (16)
Soot particles emitted from a light duty (LD) Volkswagen diesel engine running at different operating points (speed and torque levels) are analyzed for mean size determination using a laser‐based three Wavelength Extinction Method (3‐WEM). For this reason, collected soot samples are suspended using an appropriate sample preparation technique with optimized conditions of sonication as it revealed its effect on the soot mean particle size measured by 3‐WEM.
An online Scanning Mobility Particle Analyzer (SMPS) is also used to measure soot emission at identical engine operating points. Size values obtained from SMPS are lower than those of suspended soot samples obtained from 3‐WEM. The size discrepancies are mainly related to the required sample preparation procedure employed for 3‐WEM measurements. The engine operating points affect, differently, the size measurements obtained from SMPS and 3‐WEM.
Sedimentation Field‐Flow Fractionation (SdFFF) is used for density determination of soot samples based on size measurements of fractions collected at peak maxima of fractograms using the off‐line hyphenation with 3‐WEM. It is assumed that a size dependent separation of soot particles occurred with a uniform particle density over the whole size distribution. An average density value is used for the conversion of soot fractograms to size distributions. Discrepancies are also found with size distribution profiles obtained from SMPS for the same engine operating points, due to the sample preparation procedure employed for SdFFF measurements.
The identification and quantification of compounds in the gas phase becomes of increasing interest in the context of environmental protection, as well as in the analytical field. In this respect, the high extinction coefficients of vapours and gases in the ultraviolet wavelength region allow a very sensitive measurement system. In addition, the increased performance of the components necessary for setting up a measurement system, such as fibres, light sources and detectors has been improved. In particular the light sources and detectors offer improved stability, and the deep UV performance and solarisation resistance of fused silica fibres allow have been significantly optimized in the past years. Therefore a compact and reliable detection system with high measuring accuracy is developed. Within this paper possible applications of the system under development and recent results will be discussed.
Design of next-generation cdma using orthogonal complementary codes and offset stacked spreading
(2007)
This article presents an innovative code-division multiple access system architecture that is based on orthogonal complementary spreading codes and time-frequency domain spreading. The architecture has several advantages compared to conventional CDMA systems. Specifically, it offers multiple-access-interference-free operation in AWGN channels, reduces co-channel interference significantly, and has the potential for higher capacity and spectral efficiency than conventional CDMA systems. This is accomplished by using an "offset stacked" spreading modulation technique followed by quadrature amplitude modulation, which optimizes performance in a fading environment. This new spreading modulation scheme also simplifies the rate matching algorithms relevant for multimedia services and IP-based applications.
The Division Industrial Chemistry of the Swiss Chemical Society organizes periodically a two-day event for the post-graduate education of its members. This event is known as the Freiburger Symposium. This year it focussed on sustainable chemical production. The twelve talks covered the following aspects: ethical needs for sustainability standards, the required, attained, and yet to be attained sustainability goals in chemical industry. Diverse case studies showed the highly developed awareness about the sustainability issue within the chemical community.
Lattice vibrations and electronic transitions in the rare-earth metals: Praseodymium under pressure
(2004)
Praseodymium was investigated by Raman spectroscopy under pressure. A negative pressure shift of the E2g mode is observed in the dhcp phase, which indicates that the initial structural sequence hcp→Sm−type→dhcp→fcc as a whole in the regular lanthanides is associated with a softening of this mode. The pressure response of the phonon modes, observed in the monoclinic and α-uranium phases, where 4f bonding becomes important, is characteristic for anisotropic bonding properties.
Experimental and theoretical investigations of the time of equalization of the concentration of an impurity in a rectangular flow‐type chamber have been carried out. It has been shown that the process of equalization of the concentration with time is exponential in character. The characteristic equalization time has been computed using the theory of turbulent diffusion. Theoretical results describe experimental regularities with an accuracy of about 10%. The value of the coefficient of turbulent diffusion for different configurations of flows in the chamber has been obtained from a comparison of experimental and calculated results.
The structure of the separation bubble that appears in the secondary meridional flow between two coaxially rotating spheres at low and finite Reynolds number (Re) is considered. The low Re analytical study was motivated by recognizing some errors in the analytical work on this problem by Arunachalam and Majhi (1987, Q. Jl Mech. Appl. Math., 40, 47) whilst the finite Re experimental study was motivated by the desire to observe the separation bubble in the laboratory. Though the finite Re experiments were performed in a confined apparatus, they exhibit the qualitative features of the low Re theoretical predictions for the axisymmetric separation bubble that encloses two toroidal vortices symmetrically disposed above and below the mid‐plane of sphere separation, but strong effects of confinement are apparent. The flows observed include (i) a wall‐attached bubble symmetric about the mid‐plane at low Re, (ii) symmetric free‐standing bubbles at moderate Re, and (iii) an asymmetric bubble with flow separating from one sphere and attaching to the support shaft between the spheres at sufficiently high Re.
The free convection in a vertical gap is generalized to realize new analytical solutions of the Boussinesq-equations. The steady and time-dependent solutions for the temperature and velocity distribution are discussed in detail depending on the mass flux in vertical direction. The range of existence for flows with and without back flow is obtained. The transient behaviour of the solutions during the time-dependent development displays interesting physical behaviour.
The use of a TLC scanner can be regarded as a key step in high performance thin layer chromatography (HPTLC). Densitometric measurements transform the substance distribution on a TLC plate into digital computer data. Systems that allow quantitative measurements have been available for many years for either fluorescence or ultraviolet absorption measurements, while lately the reflection analysis mode for both types is the most common application. New scanning approaches are designed to aid the analyst who has common demands for TLC-densitometry without using special data, such as scanned images. Two examples that have been developed lately in the laboratories of the authors are described in this paper. These approaches were developed on the basis of current needs for analysts who employ TLC as a tool in research, as well as in routine analysis. One approach is aimed to support analysts in economically disadvantaged areas, where cost intensive apparatus is unsuitable but trace analysis by simple means is required. The other system, allows the spectral determination of chromatographic spots on TLC plates covering the ultraviolet and visible range, thus, revealing highly desired information for the analyst.
HPTLC (High Performance Thin Layer Chromatography) is a well known and versatile separation method which shows a lot of advantages and options in comparison to other separation techniques. The method is fast and inexpensive and does not need time-consuming pretreatments. Using fiber-optic elements for controlled light-guiding, the TLC-method was significantly improved: the new HPTLC-system is able to measure simultaneously at different wavelengths without destroying the plate surface or the analytes on the surface. For registration of the sample distribution on a HPTLC-plate we developed a new and sturdy diode-array HPTLC- scanner which allows registration of spectra on the TLC- plates in the range of 198 nm to 610 nm with a spectral resolution better than 1.2 nm. The spatial resolution on plate is better than 160 micrometers . In the spectral mode, the new HPTLC-scanner delivers much more information than the commonly used TLC-scanner. The measurement of 450 spectra of one separation track does not need more than three minutes. However, in the fixed wavelength mode the contour plot can be measured within 15 seconds. In this case, the signal will be summarized and averaged over a spectral range having FWHM from 10 nm to 25 nm depending on the substance under test. The new diode-array HPTLC-scanner makes various chemometric applications possible. The new method can be used easily in clinical diagnostic systems easily, e.g. for blood and uring investigations. In addition, new applications are possible. For example, the rich structured PAHs were studied. Although the separation is incomplete the 16 compounds can be quantified using suitable wavelengths.