We report improved separation of the highly toxic contact herbicides paraquat, diquat, difenzoquat, mepiquat, and chloromequat by HPTLC. Quantification was based on a new derivatization reaction using sodium tetraphenylborate. Measurements were in the wavelength range from 440 to 480 nm or from 440 to 590 nm. An LED emitting very intense light at 365 nm was used for excitation. The quantification limits of paraquat and diquat in water, using improved solid-phase extraction, was in the low ng L −1 range. The linear range covered more than two orders of magnitude. Recovery was investigated for all the compounds, and was insufficient, ranging from 11 to 92%, but the method is inexpensive, rapid, and works reliably.
There are additional long-term effects which also change the micro-structure of the polymer network and consequently the effective number of polymer chains in the material. These effects are summarized by ageing processes and will be used in the following to explain the basic assumptions of the model which can be generalized to simulate the viscous behaviour of the material. An implementation of these concepts into FEM codes is straightforward and has been carried out to the solver ABAQUS, Baaser & Ziegler (2006), Baaser et al. (2009).
An interlaboratory comparison was carried out to evaluate the effectiveness of a method based on HPTLC in which reagent-free derivatization is followed by UV/fluorescence detection. The method was tested for the determination of sucralose (C12H19C13O8; (2R,3R,4R,5S,6R)-2-[(2R,3S,4S,5S)-2,5-bis(chloromethyl)-3,4-dihydroxyoxolan-2-yl]oxy-5-chloro-6-hydroxymethyl)oxane-3, 4-diol; CAS Registry No. 56038-13-2) in carbonated and still beverages at the proposed European regulatory limits. For still beverages, a portion of the sample was diluted with methanol-water. For carbonated beverages, a portion of the sample was degassed in an ultrasonic bath before dilution. Turbid beverages were filtered after dilution through an HPLC syringe filter. The separation of sucralose was performed by direct application on amino-bonded (NH2) silica gel HPTLC plates (no cleanup needed) with the mobile phase acetonitrile-water. Sucralose was determined after reagent-free derivatization at 190 degrees C; it was quantified by measurements of both UV absorption and fluorescence. The samples, both spiked and containing sucralose, were sent to 14 laboratories in five different countries. Test portions of a sample found to contain no sucralose were spiked at levels of 30.5, 100.7, and 299 mg/L. Recoveries ranged from 104.3 to 124.6% and averaged 112% for determination by UV detection; recoveries ranged from 98.4 to 101.3% and averaged 99.9% for determination by fluorescence detection. On the basis of the results for spiked samples (blind duplicates at three levels), as well as sucralose-containing samples (blind duplicates at three levels and one split level), the values for the RSDr ranged from 10.3 to 31.4% for determinations by UV detection and from 8.9 to 15.9% for determinations by fluorescence detection. The values for the RSDR values ranged from 13.5 to 31.4% for determinations by UV detection and from 8.9 to 20.7% for determinations by fluorescence detection.
Geothermal Energy in Germany
(2009)
Hybrid drives for automotive application are extensively discussed. In contrast, the company HEINZMANN, the University of Karlsruhe and the University of Applied Sciences Offenburg concentrate on hybrid drives for industrial, offroad purposes in a joint project. These applications promise a much higher fuel saving potential, particularly if highly frequent load cycles are present. Hybrid drive systems offer additional advantages including reduced exhaust aftertreatment requirements due to engine downsizing, better engine dynamics, emissions and noise reduction.
After approximately 200 years, a comprehensive access to the texts of Humboldt's extraordinary exploration of the Americans is within sight. To open the legacy to the public for free access the Humboldt Digital Library (HDL) Project has been developing a dynamic amount of data related to studies of Alexander von Humboldt. The Library includes a range of texts, tables and images, as well as many tools that assist mining the data and navigating the system.
The HDL aims to provide an environment in which researchers can work more effectively with a wider variety of primary source materialsùtextual as well as visual. Moreover, the greatest advantage of this dynamic system is its capability to connect data from diverse locations in Humboldt's twenty-nine volumes and allow comparison with modern scientific knowledge and developments.
HDL can recreate the context of a particular text, making it possible to view images, geo-referenced and interactive maps, information about plants and animals, as well as scientific data relevant to Humboldt's observations. By introducing Web 2.0 technology implementations, we are providing new visualizations of the information published in this Digital Library. The perception of the Information Architecture is changing in the era of Web 2.0. By providing more search facilities, creating an academic network around our library and implementing new ways of multi-dimensional navigation we argue that Information Architecture can be extended to new methods of information representation. Facilitating the user navigation to the required information will always be an aim for the managers of high volume data systems. This can be achieved by implementing Information Retrieval modules based on user profiling and by improving the visualization features.
A diode array HPTLC method for dequalinium chloride in pharmaceutical preparations is presented. For separation a Nano TLC silica gel plate (Merck) is used with the mobile phase methanol-7.8% aqueous NH(4)(+)CH(3)COO(-) (17:3, v/v) over a distance of 6 cm. Dequalinium chloride shows an R(F) value of 0.58. Pure dequalinium chloride is measured in the wavelength range from 200 to 500 nm and shows several by-products, contour plot visualized in absorption, fluorescence and using the Kubelka-Munk transformation. Scanning of a single track in absorption and fluorescence measuring 600 spectra in the range from 200 to 1100 nm takes 30s. As a sample pre-treatment of an ointment it is simply dissolved in methanol and can be quantified in absorption from 315 to 340 nm. The same separation can also be quantified using fluorescence spectrometry in the range from 355 to 370 nm. A new staining method for dequalinium chloride, using sodium tetraphenyl borate/HCl in water allows a fluorescence quantification in the range from 445 to 485 nm. The linearity range of absorption and fluorescence measurements is from 10 to 2000 ng. Sugar-containing preparations like liquids or lozenges with a reduced sample pre-treatment can be reliably quantified only in fluorescence. The total for the quantification of an ointment sample (measuring four standards and five samples), including all sample pre-treatment steps takes less than 45 min!
Plant oils may be used as a sustainable, nearly CO2neutral fuel for diesel engines. This work investigates experimentally the particulate and gaseous emissions of diesel engines fuelled with different non-esterified, pure plant oils. The data are collected from three engines: a) Common rail 1.7 liter passenger car engine from Opel AG b) 12.8 liter truck engine from VOLVO c) Truck engine from MAN AG.
The emissions of the MAN engine have been used to perform AMES tests to analyze possible health impacts of plant oil operation. Finally, all emission results with plant oils have been compared to traditional gas oils.