Refine
Year of publication
Document Type
- Article (unreviewed) (19) (remove)
Language
- English (19) (remove)
Has Fulltext
- no (19)
Is part of the Bibliography
- yes (19)
Keywords
- Dünnschichtchromatographie (3)
- Vergleich (2)
- Aufzeichnung (1)
- Benzodiazepine (1)
- Bioelement (1)
- Electrolyte-gated transistors (1)
- Erfrischungsgetränk (1)
- FT-Raman spectroscopy (1)
- Feldeffekt (1)
- Flüssigkeit (1)
Institute
Open Access
- Closed Access (19) (remove)
Micro-cracks give rise to non-analytic behavior of the stress-strain relation. For the case of a homogeneous spatial distribution of aligned flat micro-cracks, the influence of this property of the stress-strain relation on harmonic generation is analyzed for Rayleigh waves and for acoustic wedge waves with the help of a simple micromechanical model adopted from the literature. For the efficiencies of harmonic generation of these guided waves, explicit expressions are derived in terms of the corresponding linear wave fields. The initial growth rates of the second harmonic, i.e., the acoustic nonlinearity parameter, has been evaluated numerically for steel as matrix material. The growth rate of the second harmonic of Rayleigh waves has also been determined for microcrack distributions with random orientation, using a model expression for the strain energy in terms of strain invariants known in a geophysical context.
Our media-artistic performances and installations, INTERCORPOREAL SPLITS (2010–2013), BUZZ (2014–2015), W ASTELAND (2015–2016), as well as our new collaboration with Bruno Latour , DE\GLOBALIZE (2018–2020), are not just about polyphony. Here, however, we rediscover them under this heading, thus giving them a new twist, while mapping out issues, mechanisms and functional modes of the polyphonic.
The Raman spectra from the chemical compounds toluene and cyclohexane obtained using a Fourier Transform (FT)-Raman spectrometer prototype have been contrasted with the Raman spectra of these same materials collected with two different commercial FT-Raman devices. The FT-Raman spectrometer consist of a Michelson interferometer, a self-designed photon counter and a reference photo-detector. The evaluation methodology of the spectral information, contrary to the commercial devices that commonly use the zero-crossing method, is carried out by re-sampling the Raman scattering and by accurately extracting the optical path information of the Michelson interferometer. The FTRaman arrangement has been built using conventional parts without disregarding the spectral frequency precision that usually such a FTRaman instruments deliver. No additional complex hardware components or costly software modules have been included in this FT-Raman device. The main Raman lines from the spectra obtained with the three FT-Raman devices have been compared with the Raman lines from the standard Raman spectra of these two materials. The values obtained using the FT-Raman spectrometer prototype have shown a frequency accuracy comparable to that obtained with the commercial devices without facing the need for a large investment. Although the proposed FT-Raman prototype cannot be directly compared to the last generation of FT-Raman spectrometers from the commercial manufacturers, such a device could give an opportunity to users that require high frequency precision in their spectral analysis and are provided with rather scarce resources.
Mice and rats make up 95% of all animals used in medical research and drug discovery and development. Monitoring of physiological functions such as ECG, blood pressure, and body temperature over the entire period of an experiment is often required. Restraining of the animals in order to obtain this data can cause great inconvenience. The use of telemetric systems solves this problem and provides more reliable results. However, these devices are mostly equipped with batteries, which limit the time of operation or they use passive power supplies, which affects the operating range. The semi-passive telemetric implant being presented is based on RFID technology and overcomes these obstacles. The device is inductively powered using the magnetic field of a common RFID reader device underneath the cage, but is also able to operate for several hours autonomously. Being independent from the battery capacity, it is possible to use the implant over a long period of time or to re-use the device several times in different animals, thus avoiding the disadvantages of existing systems and reducing the costs of purchase and refurbishment.
Electrolyte-Gated Field-Effect Transistors Based on Oxide Semiconductors: Fabrication and Modeling
(2017)
Phenolic compounds, such as flavonoids and phenolic acids, are very important substances that occur in various medicinal plants. They show different pharmacological activities which might be useful in the therapy of many diseases. Phenolic compounds have achieved an increasing interest over the last years because these compounds are easily oxidized and, thus, act as strong antioxidants. We present the chemiluminescence of different phenolic compounds measured directly on high-performance thin-layer chromatography LiChrospher® plates using the oxalic acid derivative bis(2,4,6-trichlorophenyl) oxalate (TCPO) in conjunction with H2O2. Our results indicate that chemiluminescence intensity increases with an ascending number of phenolic groups in the molecule. The method can be used to detect phenolic compounds in beverages like coffee, tea, and wine.
We present a videodensitometric quantification method for methadone in syrup, separated by thin-layer chromatography (TLC). The quantification is based on a derivation reaction with Dragendorf reagent. Measurements were carried out using a 16-bit flatbed scanner. The range of linearity covers two magnitudes of power using the Kubelka-Munk expression for data transformation. The separation method is inexpensive, fast, and reliable.
Pressure dynamics in metal-oxygen (metal-air) batteries: a case study on sodium superoxide cells
(2014)
Electrochemical reactions in metal–oxygen batteries come along with the consumption or release of gaseous oxygen. We present a novel methodology for investigating electrode reactions and transport phenomena in metal–oxygen batteries by measuring the pressure dynamics in an enclosed gas reservoir above the oxygen electrode. The methodology is exemplified by a room-temperature sodium–oxygen battery forming sodium superoxide (NaO2) in an electrolyte of diethylene glycol dimethyl ether (diglyme) and sodium trifluoromethanesulfonate (NaOSO2CF3, NaOTf). The experiments are supported by microkinetic simulations with a one-dimensional multiphysics continuum model. During galvanostatic cycling over 30 cycles, a constant oxygen consumption/release rate is observed upon discharge/charge. The number of transferred electrons per oxygen molecule is calculated to 1.01 ± 0.02 and 1.03 ± 0.02 for discharge and charge, respectively, confirming the nature of the oxygen reaction product as superoxide O2–. The same ratio is observed in cyclic voltammetry experiments with low scan rate (<1 mV/s). However, at higher scan rates, the ratio increases as a result of oxygen transport limitations in the electrolyte. We introduce electrochemical pressure impedance spectroscopy (EPIS) for simultaneously analyzing current, voltage, and pressure of electrochemical cells. Pressure recording significantly increases the sensitivity of impedance toward oxygen transport properties of the porous electrode systems. In addition, we report experimental data on the diffusion coefficient and solubility of oxygen in electrolyte solutions as important parameters for the microkinetic models.
Diode-array planar chromatography is a versatile tool for identification of pharmaceutical substances In this paper thirty-three compounds with benzodiazepine properties were investigated and the separating conditions for silica gel HPTLC plates and three mobile phases were optimized. Diode-array HPTLC makes it possible to identify all the compounds with high certainty down to a level of 20 ng. An algorithm for spectral recognition which is combined with R F values from the three separation steps into one fit factor is presented. This set of data is unique for each of the compounds investigated and enables unequivocal identification. The method is rapid, inexpensive, and sensitive down to a level of 20 ng mL −1.