Refine
Year of publication
- 2011 (107) (remove)
Document Type
- Conference Proceeding (39)
- Part of a Book (17)
- Article (reviewed) (15)
- Article (unreviewed) (12)
- Contribution to a Periodical (9)
- Other (9)
- Book (3)
- Report (2)
- Image (1)
Conference Type
- Konferenzartikel (24)
- Konferenz-Abstract (12)
- Konferenz-Poster (1)
- Konferenzband (1)
- Sonstiges (1)
Has Fulltext
- no (107) (remove)
Is part of the Bibliography
- yes (107) (remove)
Keywords
- Adsorption (5)
- Hochdruck (4)
- Metallorganisches Netzwerk (3)
- Methan (3)
- Aufreinigung (2)
- Kupfer (2)
- Lebensdauer (2)
- Mobile Learning (2)
- Wasserstoff (2)
- content adaptation (2)
Institute
Open Access
- Closed Access (47)
- Open Access (18)
- Bronze (5)
- Closed (5)
In this paper we suggest to combine the areas of media streaming services, mobile devices, and manufacturing processes to support monitoring, controlling and supervising production processes in order to achieve high levels of efficiency and environmentally friendly production. It contains a comprehensive and detailed explanation of the proposed E-Learning streaming framework, especially the adaption of streaming services to mobile environments. The key components of our approach are 1) an XML-based streaming service specification language, 2) adaption of multimedia E-Learning services to mobile environments, and 3) a media delivery platform for searching, registration, and creation of streaming services for mobile devices.
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2011. While last year’s TDP focused on the tool set created for 3D simulation in this year we describe the further improvement in this tools as well as some new features we implemented focusing on heterogeneous robot models which seem to be used in RoboCup 2012.
An additional tool was written to simply generate situation-dependent strategies. Furthermore some tools, described last year, are now integrated in one single GUI to easy things up.
A simple model is introduced that describes the interaction of surface acoustic waves (SAWs) with a 2D periodic array of objects on the surface that give rise to internal resonances. Such objects may be high-aspect ratio structures like micro-pillars fabricated of a material different from that of the substrate. The model allows for an approximate determination of the band structure for the acoustic modes in such systems. Results are presented for the dependence on structural parameters of a total bandgap in the non-radiative regime of a semi-infinite substrate, and it is shown how the frequency and radiation damping of vibrational modes can be determined that are associated with defects in the periodic 2D array.
Digital libraries are providing an increasing amount of data, which is normally structured in a classical way by documents and described by metadata as keywords. The data, even in scientific systems such as digital libraries and virtual research environments, will contain a great amount of noise or information unnecessary for our personal interests. Although there has been a lot of progress in the field of information retrieval, search techniques and other content finding methods, there is still much to be done in the field of information retrieval based on user behavior. This paper presents an approach deployed in the Humboldt Digital Library (HDL) to facilitate the retrieval of relevant information to the users of the system, making recommendations of paragraphs based on their profile and the behavior of other users who share similar profiles. The Humboldt digital library represents an innovative system of open access to the legacy of Alexander von Humboldt in a digital form on the Internet (www.avhumboldt.net). It contributes to the key question, how to present interconnected data in a proper form using information technologies.
Existing approaches solving multi-vehicle pickup and delivery problems with soft time windows typically use common benchmark sets to verify their performance. However, there is a gap from these benchmark sets to real world problems with respect to instance size and problem complexity. In this paper we show that a combination of existing approaches together with improved heuristics is able to deal with the instance sizes and complexity of real world problems. The cost savings potential of the heuristics is compared to human dispatching plans generated from the data of a European carrier.
The series of conferences on Environmental Best Practices (EBP) was inaugurated at the University of Warmia and Mazury in Olsztyn, Poland in 2006 and continued at the Jagiellonian University in Kraków, Poland in 2009. This year the University of Applied Sciences Offenburg produly hosted the third event (EPB3).
Today's network landscape consists of quite different network technologies, wide range of end-devices with large scale of capabilities and power, and immense quantity of information and data represented in different formats. Research on 3D imaging, virtual reality and holographic techniques will result in new user interfaces (UI) for mobile devices and will increase their diversity and variety. A lot of efforts are being done in order to establish open, scalable and seamless integration of various technologies and content presentation for different devices including mobile considering individual situation of the end user. This is very difficult because various kinds of devices used by different users or in different times/parallel by the same user which are not predictable and have to be recognized by the system in order to identify device capabilities. Not only the devices but also Content and User Interfaces are big issues because they could include different kinds of data format like text, image, audio, video, 3D Virtual Reality data and other upcoming formats. A very suitable and useful example of the use of such a system is mobile learning because of the large amount of varying devices with significantly different features and functionalities. This is true not only to support different learners, e.g. all learners within one learning community, but also to support the same learner using different equipment parallel and/or at different times. Those applications may be significantly enhanced by including virtual reality content presentation. Whatever the purposes are, it is impossible to develop and adapt content for all kind of devices including mobiles individually due to different capabilities of the devices, cost issues and author‘s requirement. A solution should be found to enable the automation of the content adaptation process.
The concept of m-learning which differs from other forms of e-learning covers a wide range of possibilities opened up by the convergence of new mobile technologies, wireless communication structure and distance learning development. This process of converging has launched some new goals to support m-learning where heterogeneity of devices, their operating systems (Linux, Windows, Symbian, Android etc) and supported markup languages (WML, XHTML etc), adaptive content, preferences or characteristics of user have become some of the major problems to be solved. To facilitate the learning process even more and to establish literally anytime anywhere learning, learning material/content should be available to the user always even if the user is in offline. Multiple devices used by the same user should also be synchronized among themselves and with server to provide updated learning content and to give a freedom to the user to choose any device as per his/her convenience. In this paper software architecture has been proposed to solve these problems and has been implemented by using a multidimensional flashcard learning system which synchronizes among all the devices that are being used by the user.
In large aircrafts the cabling is very complex and often causes reliability problems. This is specially true for modern In-flight Entertainment (IFE) systems, where every passenger can select a preferred movie, play computer games or be able to communicate with other travellers. Due to EMC problems, wireless communication systems (WiFi etc.) didn't succeed in solving these problems. In this paper an innovative communication system is proposed which perfectly supplements an aircraft IFE system. The key innovation of this system is to use structures that are essential parts of the airframe for data transfer, such as seat rails. Those rails consist of rectangular shapes and could easily be modified to fulfill the function of waveguides for microwaves. A waveguide as part of the seat rail would provide enormous benefits for aircrafts, such as a large bandwidth and consequently high data rates, no problems with EMC, unlimited flexibility of seat configuration, mechanical robustness with associated increase of reliability and a few additional advantages related to aircrafts such as reduction of weight and costs.
In previous work we [1] and other authors (e.g. [2]) have shown that agent-based systems are successful in optimizing delivery plans of single logistics companies and are meanwhile successfully productive in industry. In this paper we show that agent-based systems are particularly useful to also optimize transport across logistics companies. In intercompany optimization, privacy is of major importance between the otherwise competing companies. Some data has to be treated strictly private like the cost model or the constraint model. Other data like order information has to be shared. However, typically the amount of orders released to other companies has also to be limited. We show that our agent-based approach can be easily fine tuned to trade off privacy against the benefit of cooperation.
Das Virtuelle Informatiklabor soll Schülern und Studierenden den übergroßen Respekt vor dem Fach Informatik nehmen und sie beim Lernen der Inhalte unterstützen. Zu diesem Zweck werden grundlegende Algorithmen der Informatik anhand konkreter Aufgabenstellungen in interaktiven Anwendungen behandelt, um den Lernenden das explorative Erkunden zu ermöglichen. Animationen sollen das Verstehen fördern, Experimente das eigenständige, durch vielfältige Hilfen unterstützte Anwenden und Umsetzen des Gelernten. Der erste Themenbereich im Virtuellen Informatiklabor umfasst die Rekursion, die in mehreren Anwendungen präsentiert wird.
Die Ziele des Projekts waren die Einführung der Zellseparations-Technik „Feldfluss-Fraktionierung“ (FFF) zur Analyse und Fraktionierung von Hefezellen zur Weinherstellung, sowie deren Weiterentwicklung und Optimierung für den Praxiseinsatz, insbesondere Auswahl einer einfachen FFF-Variante, Vereinfachung und Kostenoptimierung, um ein für Weinbaubetriebe erschwingliches FFF-Gerät anbieten zu können. Des Weiteren sollten FFF-Techniken als online Überwachung während des Wein-Fermentationsprozesses untersucht werden. Zur Qualitätsüberwachung war es wünschenswert unerwünschte Veränderungen während des Fermentationsprozesses frühzeitig erkennen zu können, um dann zur Qualitätsoptimierung gezielte Maßnahmen gegen unerwünschte Veränderungen vornehmen zu können. Das Projekt war auch dafür gedacht als Modell-Charakter bzw. als Pilotprojekt für andere auf dem Gärungswege durch Mikroorganismen hergestellte Produkte im Lebensmittel- oder biotechnologischen Bereich zu dienen.
Introduction: Patient selection for cardiac resynchronization therapy (CRT) requires quantification of left ventricular conduction delay (LVCD). After implantation of biventricular pacing systems, individual AV delay (AVD) programming is essential to ensure hemodynamic response. To exclude adverse effects, AVD should exceed individual implant-related interatrial conduction times (IACT). As result of a pilot study, we proposed the development of a programmer-based transoesophageal left heart electrogram (LHE) recording to simplify both, LVCD and IACT measurement. This feature was implemented into the Biotronik ICS3000 programmer simultaneously with 3-channel surface ECG.
Methods: A 5F oesophageal electrode was perorally applied in 44 heart failure CRT-D patients (34m, 10f, 65±8 yrs., QRS=162±21ms). In position of maximum left ventricular deflection, oesophageal LVCD was measured between onsets of QRS in surface ECG and oesophageal left ventricular deflection. Then, in position of maximum left atrial deflection (LA), IACT in VDD operation (As-LA) was calculated by difference between programmed AV delay and the measured interval from onset of left atrial deflection to ventricular stimulus in the oesophageal electrogram. IACT in DDD operation (Ap-LA) was measured between atrial stimulus and LA..
Results: LVCD of the CRT patients was characterized by a minimum of 47ms with mean of 69±23ms. As-LA and Ap-LA were found to be 41±23ms and 125±25ms, resp., at mean. In 7 patients (15,9%), IACT measurement in DDD operation uncovered adverse AVD if left in factory settings. In this cases, Ap-LA exceeded the factory AVD. In 6 patients (13,6%), IACT in VDD operation was less than or equal 10ms indicating the need for short AVD.
Conclusion: Response to CRT requires distinct LVCD and AVD optimization. The ICS3000 oesophageal LHE feature can be utilized to measure LVCD in order to justify selection for CRT. IACT measurement simplifies AV delay optimization in patients with CRT systems irrespective of their make and model.
In-vivo and in-vitro comparison of implant-based CRT optimization - What provide new algorithms?
(2011)
Introduction: In cardiac resynchronization therapy (CRT), individual AV delay (AVD) optimization can effectively increase hemodynamics and reduce non-responder rate. Accurate, automatic and easily comprehensible algorithms for the follow-up are desirable. QuickOpt is the first attempt of a semi-automatic intracardiac electrogram (IEGM) based AVD algorithm. We aimed to compare its accuracy and usefulness by in-vitro and in-vivo studies.
Methods: Using the programmable ARSI-4 four-chamber heart rhythm and IEGM simulator (HKP, Germany), the QuickOpt feature of an Epic HF system (St. Jude, USA) was tested in-vitro by simulated atrial IEGM amplitudes between 0.3 and 3.5mV during both, manual and automatic atrial sensing between 0.2 and 1.0mV. Subsequently, in 21 heart failure patients with implanted biventricular defibrillators, QuickOpt was performed in-vivo. Results of the algorithm for VDD and DDD stimulation were compared with echo AV delay optimization.
Results: In-vitro simulations demonstrated a QuickOpt measuring accuracy of ± 8ms. Depending on atrial IEGM amplitude, the algorithm proposed optimal AVD between 90 and 150ms for VDD and between 140 and 200ms for DDD operation, respectively. In-vivo, QuickOpt difference between individual AVD in DDD and VDD mode was either 50ms (20pts) or 40ms (1pt). QuickOpt and echo AVD differed by 41 ± 25ms (7 – 90ms) in VDD and by 18 ± 24ms (17-50ms) in DDD operation. Individual echo AVD difference between both modes was 73 ± 20ms (30-100ms).
Conclusion: The study demonstrates the value of in-vitro studies. It predicted QuickOpt deficiencies regarding IEGM amplitude dependent AVD proposals constrained to fixed individual differences between DDD and VDD mode. Consequently, in-vivo, the algorithm provided AVD of predominantly longer duration than echo in both modes. Accepting echo individualization as gold standard, QuickOpt should not be used alone to optimize AVD in CRT patients.
Introduction: To simplify AV delay (AVD) optimization in cardiac resynchronization therapy (CRT), we reported that the hemodynamically optimal AVD for VDD and DDD mode CRT pacing can be approximated by individually measuring implant-related interatrial conduction intervals (IACT) in oesophageal electrogram (LAE) and adding about 50ms. The programmer-based St Jude QuickOpt algorithm is utilizing this finding. By automatically measuring IACT in VDD operation, it predicts the sensed AVD by adding either 30ms or 60ms. Paced AVD is strictly 50ms longer than sensed AVD. As consequence of those variations, several studies identified distinct inaccuracies of QuickOpt. Therefore, we aimed to seek for better approaches to automate AVD optimization.
Methods: In a study of 35 heart failure patients (27m, 8f, age: 67±8y) with Insync III Marquis CRT-D systems we recorded telemetric electrograms between left ventricular electrode and superior vena cava shock coil (LVtip/SVC = LVCE) simultaneously with LAE. By LVCE we measured intervals As-Pe in VDD and Ap-Pe in DDD operation between right atrial sense-event (As) or atrial stimulus (Ap), resp., and end of the atrial activity (Pe). As-Pe and Ap-Pe were compared with As-LA an Ap-LA in LAE, respectively.
Results: End of the left atrial activity in LVCE could clearly be recognized in 35/35 patients in VDD and 29/35 patients in DDD operation. We found mean intervals As-LA of 40.2±24.5ms and Ap-LA of 124.3±20.6ms. As-Pe was 94.8±24.1ms and Ap-Pe was 181.1±17.8ms. Analyzing the sums of As-LA + 50ms with duration of As-Pe and Ap-LA + 50ms with duration of Ap-Pe, the differences were 4.7±9.2ms and 4.2±8.6ms, resp., only. Thus, hemodynamically optimal timing of the ventricular stimulus can be triggered by automatically detecting Pe in LVCE.
Conclusion: Based on minimal deviations between LAE and LVCE approach, we proposed companies to utilize the LVCE in order to automate individual AVD optimization in CRT pacing.
We present a video-densitometric quantification method for the pain killer known as diclofenac and ibuprofen. These non-steroidal anti-inflammatory drugs were separated on cyanopropyl bonded plates using CH2Cl2, methanol, cyclohexane (95 + 5 + 40, v/v) as mobile phase. The quantification is based on a bio-effective-linked analysis using Vibrio fisheri bacteria. Within 10 min a CCD-camera registered the white light of the light-emitting bacteria. Diclofenac and ibuprofen effectively suppressed the bacterial light emission which can be used for quantification within a linear range of 10 to 2000 ng. The detection limit for ibuprofen is 20 ng and the limit of quantification 26 ng per zone. Measurements were carried out using a 16-bit ST-1603ME CCD camera with 1.56 megapixels (from Santa Barbara Instrument Group, Inc., Santa Barbara, USA). The range of linearity covers more than two magnitudes because the extended Kubelka-Munk expression is used for data transformation. The separation method is inexpensive, fast, and reliable.
High pressure adsorption phenomena are discussed for different gases on HKUST-1 (Cu3(BTC)2, commercially available product BasoliteTM C300). Sorption isotherms for hydrogen, nitrogen, methane and carbon dioxide on HKUST-1 were measured in the temperature range of 273–343 K and at pressures up to 50 MPa. The calculated surface excess adsorption capacities for all four adsorptive are one of the highest reported in the literature for HKUST-1 samples. All surface excess data were further calculated from the experimental data by using the helium buoyancy correction. A detailed description was given.
Also a procedure to calculate the absolute amount adsorbed from the surface excess amount by using two different models is shown. Using one model, the density and the volume of the adsorbed phase can be calculated. The density of the adsorbed phase ρads corresponds to the liquid density of the adsorptive at its boiling point ρliq,BP. In case of hydrogen no excess maximum was found up to 50 MPa, so that one model could not be applied. Finally, the isosteric heat of adsorption for each gas was calculated by using the Clausius–Clapeyron equation.
In dem abgeschlossenen Vorhaben „Entwicklung von Rechenmodellen zur Lebensdauervorhersage von Motorbauteilen unter thermisch-mechanischer Ermüdungsbeanspruchung“ der Forschungsvereinigung Verbrennungskraftmaschinen e. V. (FVV) wurde am Fraunhofer Institut für Werkstoffmechanik IWM in Freiburg ein Materialmodell zur Lebensdauervorhersage thermomechanisch belasteter Komponenten entwickelt. Das Modell basiert auf einem viskoplastischen Verformungsmodell für Eisengusswerkstoffe und einem mechanismenbasierten Modell für Mikrorisswachstum zur Lebensdauervorhersage.
A survey in 2000 revealed that only about 30% of the prescriptions in the European pediatric population were on the basis of evidence-based medicine (EbM). Less for radiopharmaceuticals and principally for diagnostics, radiologists throughout Europe are referred to the pediatric guidelines of the European Association of Nuclear Medicine (EANM), as none of the frequently used tracers have been evaluated in clinical trials in the different pediatric subgroups. Following a resolution to address the lack of EbM in children, the European Commission published the Pediatric Regulation EC 1901/2006 and its amendment EC 1902/2006, effective from 2007. This regulation foresees the development of evidence-based medicine in the pediatric population. This is effected through a set of principles like the mandatory pediatric investigation plan (PIP) to be included with the market authorization application (MAA), and the pediatric use market authorization (PUMA) for off-patent pharmaceuticals, and to a very small part radiopharmaceuticals with funding possibilities for pediatric-specific research through the 7th Framework Programme (7FP) of the European Union.
Routine nuclear cardiology examinations indicate heart rate, cardiac rhythm, the height of cardiac pulse and respiration rhythm. It would be of interest to study whether these data, especially if the same tests are repeated, can indicate patients’ well being in the future and perhaps patients’ life span, other factors being equal. Related old theories and suggestions are mentioned. Furthermore, some drugs like I-f channel antagonists and stress tests testing cardiac reserves could support such a study.
Crystal structures of two metal–organic frameworks (MFU‐1 and MFU‐2) are presented, both of which contain redox‐active CoII centres coordinated by linear 1,4‐bis[(3,5‐dimethyl)pyrazol‐4‐yl] ligands. In contrast to many MOFs reported previously, these compounds show excellent stability against hydrolytic decomposition. Catalytic turnover is achieved in oxidation reactions by employing tert‐butyl hydroperoxide and the solid catalysts are easily recovered from the reaction mixture. Whereas heterogeneous catalysis is unambiguously demonstrated for MFU‐1, MFU‐2 shows catalytic activity due to slow metal leaching, emphasising the need for a deeper understanding of structure–reactivity relationships in the future design of redox‐active metal–organic frameworks. Mechanistic details for oxidation reactions employing tert‐butyl hydroperoxide are studied by UV/Vis and IR spectroscopy and XRPD measurements. The catalytic process accompanying changes of redox states and structural changes were investigated by means of cobalt K‐edge X‐ray absorption spectroscopy. To probe the putative binding modes of molecular oxygen, the isosteric heats of adsorption of O2 were determined and compared with models from DFT calculations. The stabilities of the frameworks in an oxygen atmosphere as a reactive gas were examined by temperature‐programmed oxidation (TPO). Solution impregnation of MFU‐1 with a co‐catalyst (N‐hydroxyphthalimide) led to NHPI@MFU‐1, which oxidised a range of organic substrates under ambient conditions by employing molecular oxygen from air. The catalytic reaction involved a biomimetic reaction cascade based on free radicals. The concept of an entatic state of the cobalt centres is proposed and its relevance for sustained catalytic activity is briefly discussed.
Synthesis and crystal structure of a novel copper-based MOF material are presented. The tetragonal crystal structure of [ ∞ 3 ( Cu 4 ( μ 4 -O ) ( μ 2 -OH ) 2 ( Me 2 trz p ba ) 4 ] possesses a calculated solvent-accessible pore volume of 57%. Besides the preparation of single crystals, synthesis routes to microcrystalline materials are reported. While PXRD measurements ensure the phase purity of the as-synthesized material, TD-PXRD measurements and coupled DTA–TG–MS analysis confirm the stability of the network up to 230 °C. The pore volume of the microcrystalline material determined by nitrogen adsorption at 77 K depends on the synthetic conditions applied. After synthesis in DMF/H2O/MeOH the pores are blocked for nitrogen, whereas they are accessible for nitrogen after synthesis in H2O/EtOH and subsequent MeOH Soxhleth extraction. The corresponding experimental pore volume was determined by nitrogen adsorption to be V Pore = 0.58 cm 3 g - 1 . In order to characterize the new material and to show its adsorption potential, comprehensive adsorption studies with different adsorptives such as nitrogen, argon, carbon dioxide, methanol and methane at different temperatures were carried out. Unusual adsorption–desorption isotherms with one or two hysteresis loops are found – a remarkable feature of the new flexible MOF material.
Uptakes of 9.2 mmol g−1 (40.5 wt %) for CO2 at 273 K/0.1 MPa and 15.23 mmol g−1 (3.07 wt %) for H2 at 77 K/0.1 MPa are among the highest reported for metal–organic frameworks (MOFs) and are found for a novel, highly microporous copper‐based MOF (see picture; Cu turquoise, O red, N blue). Thermal analyses show a stability of the flexible framework up to 250 °C.
Metal–organic frameworks (MOFs) as highly porous materials have gained increasing interest because of their distinct adsorption properties.1–3 They exhibit a high potential for applications in gas separation and storage,4 as sensors5 as well as in heterogeneous catalysis.6 In the last few years, the H2 storage capacity of MOFs has been considerably increased. Mesoporous MOFs show high adsorption capacities for CH4, CO2, and H2 at high pressures.2, 3, 7–10 To increase the uptake of H2 and CO2 by physisorption at ambient pressure, adsorbents with small micropores as well as high specific surface areas and micropore volumes are required.11, 12 Such microporous materials seem to be more appropriate for gas‐mixture separation by physisorption than mesoporous materials. For gas separation in MOFs the interactions between the fluid adsorptive and “open metal sites” (coordinatively unsaturated binding sites) or the ligands are regarded as important.13 Industrial processes, such as natural‐gas purification or biogas upgrading, can be improved with those materials during a vapor‐pressure swing adsorption cycle (VPSA cycle) or a temperature swing adsorption cycle (TSA cycle).14 The microporous MOF series CPO‐27‐M (M=Mg, Co, Ni, Zn), for example, shows very high CO2 uptakes at low pressures (<0.1 MPa).15, 16 Concerning H2 adsorption, the microporous MOF PCN‐12 offers with 3.05 wt % the highest uptake at ambient pressure and 77 K reported to date.17
Herein, we present a novel microporous copper‐based MOF equation image[Cu(Me‐4py‐trz‐ia)] (1; Me‐4py‐trz‐ia2−=5‐(3‐methyl‐5‐(pyridin‐4‐yl)‐4H‐1,2,4‐triazol‐4‐yl)isophthalate) with extraordinarily high CO2 and H2 uptakes at ambient pressure, the H2 uptake being similar to that in PCN‐12. The ligand Me‐4py‐trz‐ia2−, which can be obtained from cheap starting materials by a three‐step synthesis in good yield, combines carboxylate, triazole, and pyridine functions and is adopted from a recently presented series of linkers,18 for which up to now only a few coordination polymers are known.
An analytical and numerical study of the wobbling dynamics of friction disks is presented. Of particular interest is the excitation mechanism taking into account two contrarian effects both originating in dry friction: the circulatory terms describing the energy input due to the sliding contacts and the friction induced damping which stabilizes the system. Balance of these terms determines the instability domain in the parameter space. It is shown that there is a slip threshold so that, if the slip is under this limit, the system remains stable. If the slip is larger than this limit, then the criterion of stability is determined by the relation between the friction coefficient and the internal damping. The limit cycle appearing in the unstable domain is also investigated. It is shown that the limit cycle can be described as a kind of a regular reverse precession of the wobbling disc. Its amplitude is limited by the geometric nonlinearity and partial contact loss. Analytic results are compared with numeric simulations.
This work provides a series of methane adsorption isotherms and breakthrough curves on one 5A zeolite and one activated carbon. Breakthrough curves of CH4 were obtained from dynamic column measurements at different temperature and pressure conditions for concentrations of 4.4 – 17.3 mol.‐% in H2/CH4 mixtures. A simple model was developed to simulate the curves using measured and calculated data inputs. The results show that the model predictions agree very well with the experiments.
Regarding the importance of adsorptive removal of carbon monoxide from hydrogen-rich mixtures for novel applications (e.g. fuel cells), this work provides a series of experimental data on adsorption isotherms and breakthrough curves of carbon monoxide. Three recently developed 5A zeolites and one commercial activated carbon were used as adsorbents. Isotherms were measured gravimetrically at temperatures of 278–313 K and pressures up to 0.85 MPa. Breakthrough curves of CO were obtained from dynamic column measurements at temperatures of 298–301 K, pressures ranging from 0.1 MPa to ca. 6 MPa and concentrations of CO in H2/CO mixtures of 5–17.5 mol%. A simple mathematical model was developed to simulate breakthrough curves on adsorbent beds using measured and calculated data as inputs. The number of parameters and the use of correlations to evaluate them were restricted in order to focus the importance of measured values. For the given assumptions and simplifications, the results show that the model predictions agree satisfactorily with the experimental data at the different operating conditions applied.
The separation of nitrogen and methane from hydrogen-rich mixtures is systematically investigated on a recently developed binder-free zeolite 5A. For this adsorbent, the present work provides a series of experimental data on adsorption isotherms and breakthrough curves of nitrogen and methane, as well as their mixtures in hydrogen. Isotherms were measured at temperatures of 283–313 K and pressures of up to 1.0 MPa. Breakthrough curves of CH4, N2, and CH4/N2 in H2 were obtained at temperatures of 300–305 K and pressures ranging from 0.1 to 6.05 MPa with different feed concentrations. An LDF-based model was developed to predict breakthrough curves using measured and calculated data as inputs. The number of parameters and the use of correlations were restricted to focus on the importance of measured values. For the given assumptions, the results show that the model predictions agree satisfactorily with the experiments under the different operating conditions applied.
In recent years, light-weight cryptography has received a lot of attention. Many primitives suitable for resource-restricted hardware platforms have been proposed. In this paper, we present a cryptanalysis of the new stream cipher A2U2 presented at IEEE RFID 2011 [9] that has a key length of 56 bit. We start by disproving and then repairing an extremely efficient attack presented by Chai et al. [8], showing that A2U2 can be broken in less than a second in the chosen-plaintext case. We then turn our attention to the more challenging known-plaintext case and propose a number of attacks. A guess-and-determine approach combined with algebraic cryptanalysis yields an attack that requires about 249 internal guesses. We also show how to determine the 5-bit counter key and how to reconstruct the 56-bit key in about 238 steps if the attacker can freely choose the IV. Furthermore, we investigate the possibility of exploiting the knowledge of a “noisy keystream” by solving a Max-PoSSo problem. We conclude that the cipher needs to be repaired and point out a number of simple measures that would prevent the above attacks.
Große Solaranlagen
(2011)
Einblick in die deutsche TGA-Landschaft. Energietechniker der Hochschule Offenbach auf Exkursion
(2011)
Home Care Applications and Ambient Assisted Living become increasingly attractive. This is caused as well by market pull, as the number of elderly people grows monotonously, as well as by technology push, as technological advances and attractive products pave the way to economically advantageous offerings. However, in real-life applications, a significant number of challenges remain. Those include seamless communication between products from different supplier, due to the lack of sufficiently standardized solutions, energy budgets, and scalability of solutions. This paper presents the experience from the InCASA project (Integrated Network for Completely Assisted Senior Citizen's Autonomy), where architectures for heterogeneous physical and logical communication flows are examined.
Applying Annual Reports
(2011)
This study presents some results from a monitoring project with night ventilation and earthto-air heat exchanger. Both techniques refer to air-based low-energy cooling. As these technologies are limited to specific boundary conditions (e.g. moderate summer climate, low temperatures during night, or low ground temperatures, respectively), water-based low-energy cooling may be preferred in many projects. A comparison of the night-ventilated building with a ground-cooled building shows major differences in both concepts.
The German Weather Service (DWD) releases a heat warning, when the weather forecast provides a warm, humid, sunny, and windless weather condition during the next days. The heat stress is calculated by the so called Klima-Michel model. If the apparent air temperature exceeds ca. 32°C / 38°C, there is a strong / extreme heat stress. The smallest forecast area is each administrative district. As people (and especially the vulnerable population) stay most of the time indoors, the heat health warning system was extended by the prediction of heat stress in typical rooms. Therewith it is feasible to forecast the heat stress using a combination of the outdoor and indoor heat stress. The prediction for the indoor heat stress is based on the same weather forecast like the Heat Health Warning Systems (HHWS).and calculates the heat stress by the PMV-model (predicted mean vote). Based on a sophisticated data analysis and simulation study, realistic but summer-critical living situations were defined and implemented in the building simulation program ESP-r. As the simulation runs especially for extreme weather conditions, a simplified building model cannot be used. Standardized input/output routines and an adaptive handover of start values provide for short run times for each forecast area. Good building designs and urban planning provide effective measures to reduce heat stress in cities. However, we have to also pay attention to the present building stock under climate change and a higher heat-wave risk. The extended German HHWS provide information for the emergency services to support the social assistants during heat waves.
Introduction: Cardiac resynchronization therapy (CRT) with left ventricular (LV) pacing is an established therapy for heart failure (HF) patients (P) with ventricular desynchronisation and reduced LV ejection fraction (EF). The aim of this study was to test the utilization of the transesophageal approach to measure arterial pulse pressure (PP) during LV pacing and electrical interventricular conduction delay (IVCD), to better select patients for CRT.
Methods: 32 HF patients (age 64 ± 10 years; 5 females, 27 males) with New York Heart Association (NYHA) class 2.8 ± 0.6, 27 ± 11 % LV EF and 155 ± 35 ms QRS duration were analysed with semi-invasive left cardiac pacing and electrocardiography. Esophageal TO8 Osypka catheter of 10.5 F diameter was perorally applied to the esophagus and placed in the position of maximum left atrial (LA) deflection and maximum LV deflection to measure PP with VAT or D00 pacing modes.
Results: Temporary transesophageal LV pacing was possible with VAT mode (n=16) and D00 mode (n=16) in all patients. In 15 Δ-PP-responders, PP was higher during LV pacing on than LV pacing off (78.3 ± 26.6 versus 65.9 ± 23.7 mmHg, P < 0.001) and NYHA class improved from 3.1 ± 0.35 to 2.1 ± 0.35 (P < 0.001) during 29 ± 26 month biventricular (BV) pacing follow-up (6 Medtronic and 9 Boston BV pacing devices). In 17 Δ-PP-non-responders, PP was not higher during LV pacing on than LV pacing off (61.5 ± 23.9 versus 60.9 ± 23.5 mmHg, P = 0.066). IVCD was significant longer in Δ-PP-responders than in Δ-PP-non-responders (87 ± 33 ms versus 37± 29 ms, P < 0.001).
Conclusion: Semi-invasive transesophageale LA and LV pacing with D00 and VAT mode and LV electrogram recording may be useful techniques to predict CRT improvement.
Introduction: Cardiac resynchronisation therapy (CRT) with atrioventricular (AV) and interventricular (VV) optimized biventricular pacing (BV) is an established therapy for heart failure (HF) patients with electrical interventricular conduction delay (IVCD). The aim of the study was to compare AV and VV delay optimization with cardiac output (CO) and acceleration index (ACI) impedance cardiographic (ICG) methods.
Methods: HF patients with IVCD 86.8 ± 33 ms (n=15, age 66 ± 10 years; 2 females, 13 males), New York Heart Association (NYHA) functional class 3.1 ± 0.4, left ventricular (LV) ejection fraction 21.3 ± 7.8 % and QRS duration 176.1 ± 31.7 ms underwent AV and VV delay optimization with CO and ACI methods (Cardioscreen, Medis GmbH, Ilmenau, Germany). After evaluation of optimal AV delay, we evaluated optimal VV delay during simultaneous LV and right ventricular (RV) pacing (LV=RV), LV before RV pacing (LV-RV) and RV before LV pacing (RV-LV).
Results: Optimal VV delay was -12.3 ± 25.9 ms LV-RV pacing with VV delay range from -80 ms LV-RV pacing to +20 ms RV-LV pacing and RV=LV pacing. Optimal AV delay after atrial sensing was 108.6 ± 20.3 ms (n=14) and optimal AV delay after atrial pacing 190 ± 14.1 ms (n=2) with AV delay range from 80 ms to 200 ms. RV versus BV pacing mode resulted in improvement of CO from 3.4 ± 1.2 l/min to 4.4 ± 1.4 l/min (p<0.001) and ACI from 0.667 ± 0.227 1/s² to 0.834 ± 0.282 1/s² (p<0.002). During 34 ± 26 month BV pacing, the NYHA class improved from 3.1 ± 0.4 to 2.1 ± 0.4 (p<0.001).
Conclusion: AV and VV delay optimized BV pacing acutely improve ICG CO and ACI and their NYHA class during long-term follow-up. ICG may be a simple and useful technique to optimize AV and VV delay in CRT.
Introduction: Cardiac resynchronisation therapy (CRT) with atrioventricular (AV) and interventricular (VV) optimized biventricular pacing (BV) is an established therapy for heart failure (HF) patients. The aim of the study was to compare AV and VV delay optimization with cardiac output (CO), cardiac index (CI), contractility index (IC) and acceleration index (ACI) impedance cardiographic (ICG) methods in CRT.
Methods: 15 HF patients (age 66 ± 10 years; 2 females, 13 males) in New York Heart Association (NYHA) class 3.1 ± 0.4, left ventricular (LV) ejection fraction 21.3 ± 7.8 % and QRS duration 176.1 ± 31.7 ms underwent AV and VV delay optimization with CO, CI, IC and ACI (Cardioscreen ®, Medis GmbH, Ilmenau, Germany) at different AV and VV delay BV pacing settings versus right ventricular (RV) pacing one day after implantation of a CRT device.
Results: Optimal AV delay after atrial sensing was 108.6 ± 20.3 ms (n=14) and optimal AV delay after atrial pacing 190 ± 14.1 ms (n=2) with AV delay range from 80 ms to 200 ms. Optimal VV delay was -12.3 ± 25.9 ms left ventricular before RV pacing. RV versus BV pacing mode resulted in improvement of CO from 3.4 ± 1.2 l/min to 4.4 ± 1.4 l/min (p<0.001), CI from 1.8 ± 0.64 l/min/m² to 2.4 ± 0.78 l/min/m² (p<0.001), IC from 0.028 ± 0.011 1/s to 0.036 ± 0.013 1/s (p<0.001) and ACI from 0.667 ± 0.227 1/s² to 0.834 ± 0.282 1/s² (p<0.002). During 34 ± 26 month BV pacing, the NYHA class improved from 3.1 ± 0.4 to 2.1 ± 0.4 (p<0.001).
Conclusion: AV and VV delay optimized BV pacing acutely improve hemodynamic parameters of transthoracic ICG and their NYHA class during long-term follow-up. ICG may be a simple and useful technique to optimize AV and VV delay in CRT.
LG Berlin "Like Button"
(2011)
Die meisten Angehörigen von beratenden Berufen - bis hin zu Rechtsanwälten - sind inzwischen um einen Auftritt im Internet nicht mehr "herumgekommen". Dass die Websites dabei in ihrer Qualität und Werbewirksamkeit weit schwanken, ist eine Sache. Dass zuweilen auch hier Unsicherheit über die richtige Gestaltung und über die Anwendbarkeit bestimmter Gesetze bestehen kann, mag aber überraschen. Welcher Rechtsanwalt etwa rechnet schon damit, dass ihm persönlich gegenüber Rechtsinstitute ins Feld geführt werden, die sich gewöhnlicherweise allein gegen Presse und Rundfunk richten.
In the year 2009 several data privacy scandals have hit the headlines where major corporations had a legitimate need for detecting fraud conducted by their own employees, but chose inappropriate measures for data screening. This contribution presents architectures and pseudonymization technology for privacy compliant fraud screening or fraud detection, in order to reduce the number of undiscovered fraud cases and to reduce the time to discovery.
Introduction: Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy for heart failure (HF) patients with ventricular desynchronization and reduced left ventricular (LV) ejection fraction. The aim of this study was to evaluate electrical ventricular desynchronization with transthoracic and transesophageal signal averaging electrocardiography in HF, to better select patients for CRT.
Methods: 13 HF patients (age 68 ± 10 years; 2 females, 11 males) with New York Heart Association (NYHA) class 2.8 ± 0.5, 28.6 ± 12.6 % LV ejection fraction and 155 ± 24 ms QRS duration (QRSD) were analysed with transthoracic and transesophageal electrocardiogram recording and novel National Intruments LabView 2009 signal averaging software. Esophageal TO Osypka catheter was perorally applied to the esophagus and placed in the position of maximum LV de-flection. The 0.05-Hz high-pass filtered surface electrocardiogram and the 10-Hz high-pass filtered bipolar transesophageal electrocardiogram were recorded with Bard EP-System and 1000-Hz sampling rate.
Results: Transesophageal LV electrogram recording was possible in all HF patients (n=13). Transesophageal interventricular conduction delay (IVCD) was 51 ± 19 ms and measured between the earliest onset of QRS in the 12-channel surface electrocardiogram and the onset of the LV deflection in the transesophageal electrocardiogram. Transesophageal intra-left ventricular delay (LVCD) was 90 ± 16 ms and measured between the onset and offset of the LV deflection in the transesophageal electrocardiogram. QRSD to transesophageal IVCD ratio was 3.43 ± 1.31 ms, QRSD to transesophageal LVCD ratio was 1.75 ± 0.28 ms and QRSD was evaluated between onset and offset of QRS signal in the 12-channel surface electrocardiogram.
Conclusion: Determination of IVCD, LVCD, QRSD-to-IVCD-ratio and QRSD-to-LVCD-ratio by transesophageal LV electrogram recording with LabView 2009 signal averaging technique may be useful parameters of ventricular desynchronisation to improve patient selection for CRT.
Im Maschinenbau ist der Trend hin zur Miniaturisierung, zu immer kompakteren und auch mechatronischen Konzepten zu beobachten. Für die mechanische Kraftübertragung bedeutet dies zunehmend höhere Drehmomentdichten bei möglichst höheren Wirkungsgraden. Diese gesteigerten Anforderungen betreffen letztlich auch die hier verbauten Maschinenelemente - zum Beispiel Profilwellen bzw. formschlüssige Profilwellenverbindungen.
In this paper we integrate the ideas of network coding and relays into an existing practical network architecture used in a wireless network scenario. Specifically, we use the COPE architecture to test our ideas. Since previous works have focused on the communication aspect at the physical layer level, we attempt to take it one step further by including the MAC layer. Our idea is based on information theoretic concepts developed by Shannon in order to reliably apply network coding to increase the net throughput.
Das Internet hat nicht nur neue Geschäftsmodelle in großer Zahl hervorgebracht, es ist auch bei der Erfindung neuer Werbeformen sehr kreativ. Neben die „klassische“ Bannerwerbung und die inzwischen auch schon intensiv weiter entwickelten Partnerprogramme (Affiliate-Marketing) treten in zunehmender Weise auch und gerade „getarnte“ Werbeformen, die mit Bezeichnungenwie „Stealth-Marketing“ schon vom Namen her für Furore sorgen sollen. Der Beitrag stellt einige dieser Werbeformen vor und beurteilt sie aus rechtlicher Sicht. Dabei erweisen sich diese Marketing-Varianten mitunter als nicht so neu wie ihre Anbieter behaupten.
Semi-invasive electromechanical target interval to guide left ventricular electrode placement
(2011)
Cardiac resynchronization therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients with inter- and intraventricular conduction delay. The aim of this pilot study was to test the feasibility of both transesophageal measurement of left ventricular (LV) electrical delay and transesophageal LV pacing prior to implantation, to better select patients for CRT.
Optical Möbius Strip
(2011)
Introduction: Cardiac resynchronization therapy (CRT) with biventricular pacing is an established therapy for heart failure (HF) patients with sinus rhythm and ventricular desynchronisation. The aim of this study was to evaluate interventricular conduction delay (IVCD) and interatrial conduction delay (IACD) before and after premature ventricular contractions (PVC) in HF patients.
Methods: 13 HF patients (age 68 ± 10 years; 2 females, 11 males) with New York Heart Association functional class 2,8 ± 0.5, left ventricular (LV) ejection fraction 28,6 ± 12,6 %, 154 ± 25 ms QRS duration and PVC were analysed with bipolar transesophageal LV and left atrial electrogram recording and National Instruments LabView 2009 software. The level of significance of the t-test is 0,005.
Results: QRS duration increases during PVC (188 ± 32 ms) in comparison to the beat before (154 ± 25 ms, P = ) and after PVC (152 ± 25 ms,). IVCD increases during PVC up to 65 ± 33 ms (51 ± 19 ms in the beat before PVC, P=0.18, 49 ± 19 ms after PVC, P = 0.12). Intra-LV delay of 90 ± 16 ms is not different in the beat before PVC, 90 ± 14 ms during PVC (P = 0.99) and 94 ± 16 ms in the beat after PVC (P = 0.38). IACD is not significantly PVC influenced (67 ± 12 ms before PVC and 65 ± 13 ms after PVC, P = 0.71). Intra-left atrial conduction delay is not significant longer during PVC (57 ± 28 ms) than in the beat before PVC (54 ± 13 ms, P = 0.51) or after PVC (54 ± 8 ms, P = 0.45). PQ duration increases significantly after PVC (224 ± 95 ms) in comparison to the beat before PVC (176± 29 ms, P =...).
Conclusion: Transesophageal left cardiac electrocardiography with LabView 2009 software can improve evaluation of IVCD and IACD before, during and after PVC in HF patient selection for CRT.
Electrical velocimetry to optimize VV delay in biventricular VVIR and DDD pacing for heart failure
(2011)
Introduction: VV delay (VVD) is the only parameter to hemodynamically optimize cardiac resynchronization therapy (CRT) for patients with atrial fibrillation (AF). Electrical velocimetry (EV) has been established to monitor thoracic electrical conductivity and to calculate hemodynamic surrogate parameters. We compared the response of this method to hemodynamic parameter changes between CRT patients with sinus rhythm (SR) and patients with AF.
Methods: VVD was individualized in 17 CRT patients in SR (12m, 5f, 67.0±7.2yrs.) after echo AV delay optimization and in 11 CRT patients in AF (10m, 1f, 69.8±9.6yrs.) using the Aesculon Cardiovascular Monitor (Osypka Medical, Berlin, Germany). Serial 30s EV recordings were accomplished, decreasing the VVD stepwise by 10ms from +60ms to -60ms between right and left ventricular stimulus. Optimal VVD was determined by the maximum of at least two of the three averaged parameters stroke volume (SV), cardiac output (CO) and cardiac index (CI). The response of SV, CO and CI was tested comparing their values in optimal VVD and suboptimal VVD. Suboptimal VVD was defined by optimal VVD±20ms.
Results: In all 28 patients in SR and AF, EV recordings resulted in optimal VVD. Between suboptimal and optimal mean VVD of 18.6±30.8ms between left and right ventricular stimulus, SV increased by 7.2±6.8%, CO by 7.8±7.2% and CI by 10.0±13.3% (all p<0.02). In the SR group with VVD of 18.8± 29.6ms, SV increased by 4.6±2.9%, CO by 5.0±2.9% and CI by 4.9±2.9% (all p<0.02). In the AF group with VVD of 18.2±4.0ms, SV increased by 10.4±8.9%, CO by 11.3±9.5% and CI by 16.4±18.2% (all p<0.02). Significant differences were not found between optimal VVD in SR and AF patients.
Conclusion: EV is a feasible serial method to individualize VVD in DDD and VVIR pacing for heart failure. Its response to hemodynamic changes demonstrates the value of EV for VVD fine-tuning.
Significance of new electrocardiographic parameters to improve cardiac resynchronization therapy
(2011)
Introduction: Oesophageal left heart electrogram (LHE) is a valuable tool providing electrocardiographic parameters for cardiac resynchronization therapy (CRT). It can be utilized to measure left ventricular (LVCD) and intra-leftventricular conduction delays (ILVCD) in heart failure patients to justify implantation of CRT systems. In the follow-up, LHE enables measurement of implant-related interatrial conduction times (IACT) which are the key intervals defining the hemodynamically optimal AV delay (AVD).
Methods: By TOSlim oesophageal electrode and Rostockfilter (Osypka AG, Rheinfelden, Germany), LHE was recorded in 39 heart failure patients (10f, 29m, 65±8yrs., QRS=163±21ms) after implantation of CRT systems according to guidelines. In position of maximal left ventricular deflection, LVCD and ILVCD were measured and compared with QRS width. In position of maximal left atrial deflection (LA), IACT was determined in VDD and DDD operation as interval As-LA and Ap-LA between atrial sense event (As) or stimulus (Ap), resp., and onset of LA. AVD was individualized using SAV =As-LA + 50ms for VDD and PAV=Ap-LA + 50ms for DDD operation.
Results: The CRT patients were characterized by minimal transoesophageal LVCD of 40ms but 73±20ms, at mean, ILVCD of 90±24ms and QRS/LVCD ratio of 2.4±0.6. The measured As-LA of 39±24ms and Ap-LA of 124±26ms resulted into SAV of 89±24ms and PAV of 174±26ms. In case of empirical AVD programming using 120ms for SAV and 180ms for PAV, the LHE revealed inverse sequences of LA and Vp in 4 patients (10%) during VDD and 13 patients (33%) in DDD pacing. In these patients, Vp preceded LA as IACT exceeded the programmed AVD.
Conclusion: Guideline indication of CRT systems is associated with LVCD of 40ms or more. Therefore, individual LVCD offers the minimal target interval that should be reached during left ventricular electrode placement to increase responder rate. Postoperatively, AV delay optimization respecting implant-related IACTs excludes adverse hemodynamic effects.
Auch wenn kaum eine andere Branche in Deutschland durch die weltweite Finanzkrise so stark getroffen wurde wie der Maschinenbau, gehört dieser nach wie vor zu den erfolgreichsten Branchen (vgl. VDMA 2010). In vielen Produktsegmenten sind deutsche Maschinenbauer Weltmarktführer. Jedoch stehen sie seit einigen Jahren Herausforderungen gegenüber, die zu einem Umdenken und einer Neuausrichtung führen. Insbesondere das nach wie vor existente Problem der Produktpiraterie sowie die zumeist aus den asiatischen Räumen eingetretenen Wettbewerber, die für einen enormen Preisdruck sorgen, haben in den letzten Jahren dazu geführt, dass Standardmaschinen nur noch eine geringe Profitabilität aufweisen. Mit produktbegleitenden Dienstleistungen (Services) hingegen lasst sich mit durchschnittlich 21 % eine rund viermal so hohe operative Marge realisieren wie mit Maschinen (vgl. Schmiedeberg/Strahle/Bendig 2010, S. 3). Annahmen gehen davon aus, dass Services das Potenzial haben, einen Umsatzanteil von bis zu 35 % und damit einen Gewinnanteil von bis zu 60 % zu erreichen.
Introduction: Cardiac resynchronization therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients (P) with ventricular desynchronisation, but not all patients improved clinically. Aim of this study was to evaluate electrical intra-left ventricular conduction delay (LVCD) and interventricular conduction delay (IVCD), to better select patients for CRT.
Methods: 65 HF patients (age 63.4 ± 10.6 years; 7 females, 58 males) with New York Heart Association (NYHA) class 3 ± 0.2, 24.4 ± 6.7 % left ventricular (LV) ejection fraction and 167.4 ± 35.6 ms QRSD were included. Esophageal TO Osypka focused hemispherical electrodes catheter was perorally applied in position of maximum LV deflection to measure LVCD between onset and offset of LV deflection and IVCD between earliest onset of QRS in the 12-channel surface ECG and onset of LV deflection in the focused bipolar transesophageal LV electrogram.
Results: There were 50 responders with LVCD of 76.5 ± 20.4 ms, IVCD of 80.5 ± 26.1 ms (P=0.34) and QRSD of 171 ± 37.7 ms. 15 non-responders had longer LVCD of 90 ± 28.5 ms (P = 0.045), shorter IVCD of 50.1 ± 29.1 ms (P < 0.001) and QRSD of 155.3 ± 25 ms (P=0.14). During 21.3 ± 20.3 month BV pacing follow-up, the responder`s NYHA classes improved from 3 ± 0.2 to 2. ± 0.3 (P < 0.001) whereas the non-responders NYHA classes did not improve from 3 ± 0.2 to 2.9 ± 0.3 (P = 0.43) during 15.7 ± 13.9 month BV pacing follow-up (53 Boston, 10 Medtronic and 2 St. Jude CRT devices).
Conclusion: Determination of electrical LVCD and IVCD by focused bipolar transesophageal LV electrogram recording may be an additional useful technique to improve patient selection for CRT.
Introduction: Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy for heart failure (HF) patients with ventricular desynchronisation and reduced left ventricular (LV) function. The aim of this study was to evaluate preejection period (PEP) and left ventricular ejection time (LVET) with transthoracic signal averaging impedance and electrocardiography in HF patients with and without BV pacing.
Methods: 10 HF patients (age 68.9 ± 8 years; 2 females, 9 males) with New York Heart Association (NYHA) class 2,9 ± 0.5, 30.9 ± 10.5 % LV ejection fraction and 159.4 ± 22.9 ms QRS duration were analysed with transthoracic impedance and electrocardiography (Cardioscreen Medis, Ilmenau, Germany) and novel National Intruments LabView 2009 signal averaging software. One day after BV pacing device implantation, AV and VV delays were optimized by transthoracic impedance cardiography and stroke volume (SV) and cardiac output (CO) were gained by Cardioscreen.
Results: Transthoracic impedance and electrocardiography AV and VV delay opimization was possible in all HF patients with BV pacing devices (n= 10). PEP was 154 ± 24ms without BV pacing and measured between onset of QRS in the surface electrocardiogram and onset of ventricular deflection in the impedance cardiogram. LVET was 342 ± 65ms without BV pacing and measured between onset and offset of ventricular deflection in the impedance cardiogram. The use of optimal AV and VV delay BV pacing resulted in improvement of SV from 64.1 ± 26.5 ml to 94.1 ± 33.96 ml (P < 0.05) and CO from 4.05 ± 1.36 l/min to 6.44 ± 1.56 l/min (P < 0.05).
Conclusion: PEP and LVET may be useful parameters of ventricular Desynchronisation. AV and VV delay optimized BV pacing improve SV and CO. Impedance and electrocardiography with LabView 2009 signal averaging may be a simple and useful technique to optimize CRT.
Der Fall ist gar nicht so selten: Ein Verbraucher bucht oder kauft grenzüberschreitend, man streitet sich – und schon steht die Frage nach dem richtigen internationalen Gerichtsstand im Raum. Der EuGH hat hierzu nun grundlegend Stellung genommen (EuGH, Urt. v. 7.12.2010 – Rs. C-585/08, Rs. C-144/09 – Pammer ./. Reederei Schlüter und Hotel Alpenhof ./. Heller, CR 2011, 108).
BGH "Original Kanchipur"
(2011)
Medienmarketing
(2011)