Refine
Year of publication
Document Type
- Conference Proceeding (151)
- Article (reviewed) (58)
- Bachelor Thesis (43)
- Article (unreviewed) (17)
- Master's Thesis (10)
- Book (7)
- Part of a Book (5)
- Letter to Editor (2)
- Patent (2)
- Contribution to a Periodical (1)
Conference Type
- Konferenzartikel (122)
- Konferenz-Abstract (23)
- Sonstiges (5)
- Konferenz-Poster (1)
Language
- English (196)
- German (100)
- Other language (1)
- Russian (1)
Keywords
- Kommunikation (6)
- Applikation (5)
- Batterie (5)
- Brennstoffzelle (5)
- Netzwerk (4)
- Codierung (3)
- Eingebettetes System (3)
- Elektrode (3)
- Energieversorgung (3)
- Gehirn (3)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (298) (remove)
Open Access
- Closed Access (298) (remove)
Die Geschäftsleitung und Führungskräfte von Eller Repro+Druck beschlossen im Juli 1994 die Teilnahme am damls noch neuen EU-Öko-Audit. Die Durchführung des Audits ist für 1996 geplant. Zwei Diplomanden der FH Offenburg wurde die Möglichkeit gegeben, als externe Berater für Eller Repro+Druck ihre Diplomarbeit über die Vorbereitung zum Öko-Audit zu schreiben. Der Betrieb (170 Mitarbeiter) verfügt über elektronische Bildverarbeitung auf Scitex- und Mac-Schiene, derzeit noch konventionelle Plattenkopie und -entwicklung, fünf Offsetrotationen sowie Weiterverarbeitung mit Sammelheftern und Falzmaschinen. Der Referent berichtet über die Erfahrungen, die sein Unternehmen bis zum Herbst 1995 mit der Vorbereitung zum Öko-Audit gemacht hat, und gibt Praxistips. Zusammen mit den Beratern wurden eine Aufnahme der betrieblichen Situation durchgeführt, Maßnahmen geplant und zum Teil durchgeführt.
The IEEE 1588 precision time protocol (PTP) is a time synchronization protocol with sub-microsecond precision primarily designed for wired networks. In this letter, we propose wireless precision time protocol (WPTP) as an extension to PTP for multi-hop wireless networks. WPTP significantly reduces the convergence time and the number of packets required for synchronization without compromising on the synchronization accuracy.
In this paper we integrate the ideas of network coding and relays into an existing practical network architecture used in a wireless network scenario. Specifically, we use the COPE architecture to test our ideas. Since previous works have focused on the communication aspect at the physical layer level, we attempt to take it one step further by including the MAC layer. Our idea is based on information theoretic concepts developed by Shannon in order to reliably apply network coding to increase the net throughput.
Home Care Applications and Ambient Assisted Living become increasingly attractive. This is caused as well by market pull, as the number of elderly people grows monotonously, as well as by technology push, as technological advances and attractive products pave the way to economically advantageous offerings. However, in real-life applications, a significant number of challenges remain. Those include seamless communication between products from different supplier, due to the lack of sufficiently standardized solutions, energy budgets, and scalability of solutions. This paper presents the experience from the InCASA project (Integrated Network for Completely Assisted Senior Citizen's Autonomy), where architectures for heterogeneous physical and logical communication flows are examined.
Who is Who? Joseph Fourier
(2015)
Die Vielfalt der Protokolle, die praktisch auf allen Ebenen der Netzwerkkommunikation zu berücksichtigen ist, stellt eine der großen Herausforderungen bei der fortschreitenden Automatisierung des intelligenten Hauses dar. Unter dem Überbegriff Internet der Dinge (Internet of Things) entstehen gegenwärtig zahlreiche neue Entwicklungen, Standards, Allianzen und so genannte Ökosysteme. Diese haben die Absicht einer horizontalen Integration gewerkeübergreifender Anwendungen und verfolgen fast alle das Ziel, die Situation zu vereinfachen, die Entwicklungen zu beschleunigen und Markterfolge zu erreichen. Leider macht diese Vielfalt momentan die Welt aber eher noch komplexer und bringt damit das Risiko mit sich, genau das Gegenteil der ursprünglichen Absichten zu erreichen. Dieser Beitrag versucht, die Entwicklungen möglichst systematisch zu kategorisieren und mögliche Lösungsansätze zu beschreiben.
A novel approach of a test environment for embedded networking nodes has been conceptualized and implemented. Its basis is the use of virtual nodes in a PC environment, where each node executes the original embedded code. Different nodes run in parallel, connected via so-called virtual channels. The environment allows to modifying the behavior of the virtual channels as well as the overall topology during runtime to virtualize real-life networking scenarios. The presented approach is very efficient and allows a simple description of test cases without the need of a network simulator. Furthermore, it speeds up the process of developing new features as well as it supports the identification of bugs in wireless communication stacks. In combination with powerful test execution systems, it is possible to create a continuous development and integration flow.
Die Einführung der extrakorporalen Zirkulation unter Verwendung eines medikamentös induzierten Herzstillstands ermöglicht der Herzchirurgie die Herzoperationen, wie sie heute bekannt sind. Eine große Debatte besteht in der optimalen Zusammensetzung und Anwendungsweise der kardioplegischen Lösungen [6]. In der Helios Klinik für Herzchirurgie in Karlsruhe werden die kalte, kristalloide Kardioplegie nach Bretschneider und die modifizierte, kalte Blutkardioplegie nach Calafiore verwendet. Die vorliegende Arbeit beschäftigt sich mit der Frage, ob die Wahl der Kardioplegie Einwirkungen auf den intraoperativen und postoperativen Verlauf einer Bypass-Operation hat.
In der dazu angefertigten Studie wurden die Daten von 135 KHK Patienten retrospektiv erfasst und statistisch analysiert. Darunter wurden 81 Patienten mit der kalten Blutkardioplegie nach Calafiore behandelt und 53 Patienten mit der kristalloiden HTKLösung nach Bretschneider. Die demografischen Daten und Dringlichkeit der Operationen unterscheiden sich nicht signifikant voneinander. Bei den intraoperativen Parametern sind hinsichtlich der Hämoglobin-, Natrium-, und Kaliumkonzentration signifikante Unterschiede erkennbar. Weitere intraoperative Laborwerte zeigen keine Signifikanz. Die intraoperativen Parameter der Myokardprotektionsverfahren unterscheiden sich bezüglich der verabreichten Kardioplegiemenge. Bei postoperativen Parametern sind keine besonderen Signifikanzen notiert.
Die kristalloide Kardioplegie nach Bretschneider wie auch die modifizierte kalte Blutkardioplegie nach Calafiore sind sichere und effektive Verfahren. Einige Unterschiede konnten zugunsten der Blutkardioplegie nach Calafiore gefunden werden, die spezifisch für das jeweilige Verfahren sind. Zwingende Argumente für oder gegen eines dieser Verfahren konnten nicht gefunden werden.
Introduction: Cardiac resynchronization therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients (P) with ventricular desynchronisation, but not all patients improved clinically. Aim of this study was to evaluate electrical intra-left ventricular conduction delay (LVCD) and interventricular conduction delay (IVCD), to better select patients for CRT.
Methods: 65 HF patients (age 63.4 ± 10.6 years; 7 females, 58 males) with New York Heart Association (NYHA) class 3 ± 0.2, 24.4 ± 6.7 % left ventricular (LV) ejection fraction and 167.4 ± 35.6 ms QRSD were included. Esophageal TO Osypka focused hemispherical electrodes catheter was perorally applied in position of maximum LV deflection to measure LVCD between onset and offset of LV deflection and IVCD between earliest onset of QRS in the 12-channel surface ECG and onset of LV deflection in the focused bipolar transesophageal LV electrogram.
Results: There were 50 responders with LVCD of 76.5 ± 20.4 ms, IVCD of 80.5 ± 26.1 ms (P=0.34) and QRSD of 171 ± 37.7 ms. 15 non-responders had longer LVCD of 90 ± 28.5 ms (P = 0.045), shorter IVCD of 50.1 ± 29.1 ms (P < 0.001) and QRSD of 155.3 ± 25 ms (P=0.14). During 21.3 ± 20.3 month BV pacing follow-up, the responder`s NYHA classes improved from 3 ± 0.2 to 2. ± 0.3 (P < 0.001) whereas the non-responders NYHA classes did not improve from 3 ± 0.2 to 2.9 ± 0.3 (P = 0.43) during 15.7 ± 13.9 month BV pacing follow-up (53 Boston, 10 Medtronic and 2 St. Jude CRT devices).
Conclusion: Determination of electrical LVCD and IVCD by focused bipolar transesophageal LV electrogram recording may be an additional useful technique to improve patient selection for CRT.
In this work, we consider a duty-cycled wireless sensor network with the assumption that the on/off schedules are uncoordinated. In such networks, as all nodes may not be awake during the transmission of time synchronization messages, nodes will require to re-transmit the synchronization messages. Ideally a node should re-transmit for the maximum sleep duration to ensure that all nodes are synchronized. However, such a proposition will immensely increase the energy consumption of the nodes. Such a situation demands that there is an upper bound of the number of retransmissions. We refer to the time a node spends in re-transmission of the control message as broadcast duration. We ask the question, what should be the broadcast duration to ensure that a certain percentage of the available nodes are synchronized. The problem to estimate the broadcast duration is formulated so as to capture the probability threshold of the nodes being synchronized. Results show the proposed analytical model can predict the broadcast duration with a given lower error margin under real world conditions, thus demonstrating the efficiency of our solution.
Cardiac resynchronization therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients with inter- and intraventricular conduction delay. The aim of this pilot study was to test the feasibility of both transesophageal measurement of left ventricular (LV) electrical delay and transesophageal LV pacing prior to implantation, to better select patients for CRT.
Introduction: Cardiac resynchronization therapy (CRT) with biventricular pacing is an established therapy for heart failure (HF) patients with sinus rhythm and ventricular desynchronisation. The aim of this study was to evaluate interventricular conduction delay (IVCD) and interatrial conduction delay (IACD) before and after premature ventricular contractions (PVC) in HF patients.
Methods: 13 HF patients (age 68 ± 10 years; 2 females, 11 males) with New York Heart Association functional class 2,8 ± 0.5, left ventricular (LV) ejection fraction 28,6 ± 12,6 %, 154 ± 25 ms QRS duration and PVC were analysed with bipolar transesophageal LV and left atrial electrogram recording and National Instruments LabView 2009 software. The level of significance of the t-test is 0,005.
Results: QRS duration increases during PVC (188 ± 32 ms) in comparison to the beat before (154 ± 25 ms, P = ) and after PVC (152 ± 25 ms,). IVCD increases during PVC up to 65 ± 33 ms (51 ± 19 ms in the beat before PVC, P=0.18, 49 ± 19 ms after PVC, P = 0.12). Intra-LV delay of 90 ± 16 ms is not different in the beat before PVC, 90 ± 14 ms during PVC (P = 0.99) and 94 ± 16 ms in the beat after PVC (P = 0.38). IACD is not significantly PVC influenced (67 ± 12 ms before PVC and 65 ± 13 ms after PVC, P = 0.71). Intra-left atrial conduction delay is not significant longer during PVC (57 ± 28 ms) than in the beat before PVC (54 ± 13 ms, P = 0.51) or after PVC (54 ± 8 ms, P = 0.45). PQ duration increases significantly after PVC (224 ± 95 ms) in comparison to the beat before PVC (176± 29 ms, P =...).
Conclusion: Transesophageal left cardiac electrocardiography with LabView 2009 software can improve evaluation of IVCD and IACD before, during and after PVC in HF patient selection for CRT.
Mit längerfristigen Nutzerbefragungen in zwei unmittelbar benachbarten Bürogebäuden in Freiburg wurden das Temperaturempfinden der Nutzer und deren Zufriedenheit mit dem thermischen Raumkomfort zweimal täglich erfasst. Ein Bürogebäude wird im Sommer mit einem maschinellen Nachtlüftungskonzept konditioniert und das zweite verfügt über eine Betonkerntemperierung und eine Zu- und Abluftanlage. Auf Basis der vorhandenen Daten aus der Erhebung wurde mit Hilfe von Regressionsanalysen ein Modell zur Vorhersage der Komforttemperatur berechnet und mit den Modellen in DIN EN 15251 verglichen.
Chronic insomnia is defined by difficulties in falling asleep, maintaining sleep, and early morning awakening, and is coupled with daytime consequences such as fatigue, attention deficits, and mood instability. These symptoms persist over a period of at least 3 months (Diagnostic and Statistical Manual 5 criteria). Chronic insomnia can be a symptom of many medical, neurological, and mental disorders. As a disorder, it incurs substantial health-care and occupational costs, and poses substantial risks for the development of cardiovascular and mental disorders, including cognitive deficits. Family and twin studies confirm that chronic insomnia can have a genetic component (heritability coefficients between 42% and 57%), whereas the investigation of autonomous and central nervous system parameters has identified hyperarousal as a final common pathway of the pathophysiology, implicating an imbalance of sleep–wake regulation consisting of either overactivity of the arousal systems, hypoactivity of the sleep-inducing systems, or both. Insomnia treatments include benzodiazepines, benzodiazepine-receptor agonists, and cognitive behavioural therapy. Treatments currently under investigation include transcranial magnetic or electrical brain stimulation, and novel methods to deliver psychological interventions.
Ranging errors are inevitable in all local positioning systems, including those based on Time-of-Flight (ToF) technique. Results of experiments show that the major cause for these errors is a signal degradation from multipath propagation. This effect is especially critical in case of Non-Light-of-Sight (NLOS) conditions. This paper describes causes that affects ranging errors for nanoLOC™-TOF-technology and presents estimations for the probability density functions of such errors under different NLOS conditions. The provided estimations allow the improvement of the accuracy of the localization through the subsequent mitigation of the ranging errors from the measurements. Additionally, it is proposed to increase the number of cases of NLOS-conditions for the improvement of the accuracy.
Both German and French Air-Source Heat Pump (ASHP) markets have been enjoying an overall upwards trend for many years but, nevertheless, they remain merely slightly penetrated. In terms of market players and their share, the French market is aptly diversified, whereas the German one, being utterly dominated by one single manufacturer, is badly in need of some diversification. At the same time Korean ASHP manufacturers are targeting the French but not German ASHP market. The main purpose of the paper is to find out likely reasons for their one-sided engagement, primarily those associated with the ASHP technology and its system-related aspects.
Streustrahlung in der Ultraschall-Computertomographie zur Verifizierung der Echtheit von Perlen
(2017)
This paper describes a new analysis method developed to distinguish real from fake
pearls using non-ionizing, non-destructive ultrasound computed tomography (USCT): In the USCT Shepp-Logan-filtered time-of-flight image, a fake pearl shows irregular, asymmetric
scattering of ultrasound, whereas the pattern in a natural pearl is regular and symmetric.
We strongly assume that pattern recognition of the scattering of ultrasound cannot only
play an important role in verifying pearls, but also in testing other materials and tissues in
(bio-)medical engineering. Furthermore, and most importantly, this new approach could
be helpful for a variety of clinical diagnoses using high-resolution 3D-USCT, such as the
detection of X-ray-negative micro-calcifications in early breast cancer. Moreover looking
at scattering patterns in dedicated positron emission tomography systems may promote
new developments in nuclear medicine diagnostics.
Since their dawning, space communications have been among the strongest driving applications for the development of error correcting codes. Indeed, space-to-Earth telemetry (TM) links have extensively exploited advanced coding schemes, from convolutional codes to Reed-Solomon codes (also in concatenated form) and, more recently, from turbo codes to low-density parity-check (LDPC) codes. The efficiency of these schemes has been extensively proved in several papers and reports. The situation is a bit different for Earth-to-space telecommand (TC) links. Space TCs must reliably convey control information as well as software patches from Earth control centers to scientific payload instruments and engineering equipment onboard (O/B) spacecraft. The success of a mission may be compromised because of an error corrupting a TC message: a detected error causing no execution or, even worse, an undetected error causing a wrong execution. This imposes strict constraints on the maximum acceptable detected and undetected error rates.
Nachweise für die Stabilität von Regelkreisen, deren Stellgrößen an ihre Begrenzungen gelangen können und bei denen die Regler Integratoren oder andere dynamische Glieder sowie Anti-Windup-Maßnahmen enthalten, sind gewöhnlich sehr aufwändig zu führen. Bei PI-Zustandsreglern, die mittels der in [1] vorgestellten Methode in einem mehrstufigen Verfahren für Regelstrecken entworfen wurden, die bis auf die Stellgrößenbegrenzungen linear sind, lassen sich jedoch äußerst hilfreiche allgemeine Stabilitätsaussagen treffen, die den konkreten Stabilitätsnachweis für das Gesamtsystem– selbst unter Einbeziehung von Beobachtern – erheblich vereinfachen. Im vorliegenden Beitrag werden die diesbezüglichen, auf Steuerbarkeitsbetrachtungen beruhenden, Zusammenhänge für zeitdiskrete Regelkreise aufgezeigt sowie daraus exemplarisch mittels Ljapunow-Funktionen eine einfache Reglerformel für Zustandsregler abgeleitet, die auch im Begrenzungsfall stabil arbeiten. Ein Beispielaus der elektrischen Antriebstechnik illustriert die Anwendbarkeit der vorgestellten Methode.
The combination of fossil-derived fuels with ethanol and methanol has acquired relevance and attention in several countries in recent years. This trend is strongly affected by market prices, constant geopolitical events, new sustainability policies, new laws and regulations, etc. Besides bio-fuels these materials also include different additives as anti-shock agents and as octane enhancer. Some of the chemical compounds in these additives may have harmful properties for both environment and public health (besides the inherent properties, like volatility). We present detailed Raman spectral information from toluene (C7H8) and ethanol (C2H6O) contained in samples of ElO gasoline-ethanol blends. The spectral information has been extracted by using a robust, high resolution Fourier-Transform Raman spectrometer (FT-Raman) prototype. This spectral information has been also compared with Raman spectra from pure additives and with standard Raman lines in order to validate its accuracy in frequency. The spectral information is presented in the range of 0 cm-1 to 3500 cm-1 with a resolution of 1.66cm-1. This allows resolving tight adjacent Raman lines like the ones observed around 1003cm-1 and 1030cm-1 (characteristic lines of toluene). The Raman spectra obtained show a reduced frequency deviation when compared to standard Raman spectra from different calibration materials. The FT-Raman spectrometer prototype used for the analysis consist basically of a Michelson interferometer and a self-designed photon counter cooled down on a Peltier element arrangement. The light coupling is achieved with conventional62.5/125μm multi-mode fibers. This FT-Raman setup is able to extract high resolution and frequency precise Raman spectra from the additives in the fuels analyzed. The proposed prototype has no additional complex hardware components or costly software modules. The mechanical and thermal disturbances affecting the FT-Raman system are mathematically compensated by accurately extracting the optical path information of the Michelson interferometer. This is accomplished by generating an additional interference pattern with a λ = 632.8 nm Helium-Neon laser (HeNe laser). It enables the FT-Raman system to perform reliable and clean spectral measurements from the materials under observation.
Targeting complex fractionated atrial electrocardiograms by automated algorithms during ablation of persistent atrial fibrillation has produced conflicting outcomes in previous electrophysiological studies and catheter ablation of atrial fibrillation and ventricular tachycardia. The aim of the investigation was to evaluate atrial and ventricular high frequency fractionated electrical signals with signal averaging technique.
Methods: Signal averaging electrocardigraphy allows high resolution ECG technique to eliminate interference noise signals in the recorded ECG. The algorithm use automatic ECG trigger function for signal averaged transthoracic, transesophageal and intra-cardiac ECG signals with novel LabVIEW software.
Results: The analysis in the time domain evaluated fractionated atrial signals at the end of the signal averaged P-wave and fractionated ventricular signals at the end of the QRS complex. We evaluated atrial flutter in the time domain with two-to-one atrioventricular conduction, 212.0 ± 4.1 ms atrial cycle length, 426.0 ± 8.2 ms ventricular cycle length, 58.2 ± 1.8 ms P-wave duration, 119.6 ± 6.4 ms PQ duration, 103.0 ± 2.4 ms QRS duration and 296.4 ± 6.8 ms QT duration. The analysis in the frequency domain evaluated high frequency fractionated atrial signals during the P-wave and high frequency fractionated ventricular signals during QRS complex.
Conclusions: Spectral analysis of signal averaging electrocardiography with novel LabVIEW software can be utilized to evaluate atrial and ventricular conduction delays in patients with atrial fibrillation and ventricular tachycardia. Complex fractionated atrial and ventricular electrocardiograms may be useful parameters to evaluate electrical cardiac bradycardia and tachycardia signals in atrial fibrillation and ventricular tachycardia ablation.
The industry of the agave-derived bacanora, in the northern Mexican state of Sonora, has been growing substantially in recent years. However, this higher demand still lies under the influences of a variety of social, legal, cultural, ecological and economic elements. The governmental institutions of the state have tried to encourage a sustainable development and certain levels of standardization in the production of bacanora by applying different economical and legal strategies. However, a large portion of this alcoholic beverage is still produced in a traditional and rudimentary fashion. Beyond the quality of the beverage, the lack of proper control, by using adequate instrumental methods, might represent a health risk, as in several cases traditional-distilled beverages can contain elevated levels of harmful materials. The present article describes the qualitative spectral analysis of samples of the traditional-produced distilled beverage bacanora in the range from 0 cm−1 to 3500 cm−1 by using a Fourier Transform Raman spectrometer. This particular technique has not been previously explored for the analysis of bacanora, as in the case of other beverages, including tequila. The proposed instrumental arrangement for the spectral analysis has been built by combining conventional hardware parts (Michelson interferometer, photo-diodes, visible laser, etc.) and a set of self-developed evaluation algorithms. The resulting spectral information has been compared to those of pure samples of ethanol and to the spectra from different samples of the alcoholic beverage tequila. The proposed instrumental arrangement can be used the analysis of bacanora.
Die Kommunikationstechnik für die Zählerfernauslesung (Smart Metering) und für die Energieerzeugungs- und -verteilnetze (Smart Grid) hat das Potenzial, zu einer der ersten hoch skalierten M2M-Anwendungen zu werden. In den vergangenen Jahren konnten zwei vielversprechende Entwicklungen im Umfeld der drahtlosen Kommunikation für die Smart-Grid-Kommunikation vorbereitet werden, die das Marktgeschehen über Deutschland und über die Versorgungstechnik hinaus beeinflussen könnten. Neben der Spezifikation der OMS-Gruppe ist die Erarbeitung eines Schutzprofils (Protection Profile, PP) sowie einer Technischen Richtlinie (TR) für die Kommunikationseinheit eines intelligenten Messsystems (Smart Meter Gateway) durch das Bundesamt für Sicherheit in der Informationstechnik (BSI) zu nennen. Diese greifen, wie der Beitrag beschreibt, den Stand der Technik auf und geben praxisorientierte Umsetzungen vor.
Private households constitute a considerable share of Europe's electricity consumption. The current electricity distribution system treats them as effectively passive individual units. In the future, however, users of the electricity grid will be involved more actively in the grid operation and can become part of intelligent networked collaborations. They can then contribute the demand and supply flexibility that they dispose of and, as a result, help to better integrate renewable energy in-feed into the distribution grids.
Orthogonal Frequency Division Multiplexing (OFDM) ist ein modernes Mehrträgermodulationsverfahren, das sich gut an die besonderen Eigenschaften eines Mobilfunkkanals mit zeitvarianter Mehrwegeausbreitung anpassen kann. Es eignet sich aufgrund seines Aufbaus vor allem für Breitbandübertragungen und wird in vielen aktuellen Funksystemen wie LTE, WLAN, DVB-T usw. eingesetzt. In DSL wird die Basisbandvariante von OFDM eingesetzt, die „Discrete Multitone Transmission (DMT)“ genannt wird. Viele Aussagen über OFDM lassen sich auch auf DMT übertragen.
Moduliert wird mit Hilfe der inversen Fouriertransformation, die viele Unterträger parallel verarbeitet und am Schluss aufsummiert. Dies hat den Nachteil einer hohen Signalfluktuation, die bei Verstärkern zu Problemen führt.
Reale Verstärker haben eine nichtlineare Verstärkungskennlinie mit einer maximalen Ausgangsamplitude. Wird diese überschritten, wird das Signal abgeschnitten (geclippt). Dies hat sowohl vermehrte Bitfehler aufgrund des Orthogonalitätsverlustets der Unterträgersignale zueinander zur Folge, als auch eine erhöhte Außerbandabstrahlung.
Eine mögliche Lösung besteht darin, die Aussteuerung des Verstärkers klein zu halten. Daraus resultieren jedoch erhöhte Kosten und eine verringerte Energieeffizienz. Man ist daher bemüht die Signalfluktuation möglichst gering zu halten. Eine Maßzahl für die Amplitudenschwankungen ist das Peak-to-Average-Power-Ratio (PAPR).
Um das PAPR zu senken, gibt es eine ganze Reihe unterschiedlicher Verfahren. In dieser Arbeit werden die gängigsten davon vorgestellt und das Interleavingverfahren, die Tone Reservations (TR) und das Active Constellation Expanding (ACE) genauer untersucht.
Background: The electrical field (E-field) of the biventricular (BV) stimulation is essential for the success of cardiac resynchronization therapy (CRT) in patients with cardiac insufficiency and widened QRS complex. 3D modeling allows the simulation of CRT and high frequency (HF) ablation.
Purpose: The aim of the study was to model different pacing and ablation electrodes and to integrate them into a heart model for the static and dynamic simulation of BV stimulation and HF ablation in atrial fibrillation (AF).
Methods: The modeling and simulation was carried out using the electromagnetic simulation software. Five multipolar left ventricular (LV) electrodes, one epicardial LV electrode, four bipolar right atrial (RA) electrodes, two right ventricular (RV) electrodes and one HF ablation catheter were modeled. Different models of electrodes were integrated into a heart rhythm model for the electrical field simulation (fig.1). The simulation of an AV node ablation at CRT was performed with RA, RV and LV electrodes and integrated ablation catheter with an 8 mm gold tip.
Results: The RV and LV stimulation were performed simultaneously at amplitude of 3 V at the LV electrode and 1 V at the RV electrode, each with a pulse width of 0.5 ms. The far-field potentials generated by the BV stimulations were perceived by the RA electrode. The far-field potential at the RA electrode tip was 32.86 mV. A far-field potential of 185.97 mV resulted at a distance of 1 mm from the RA electrode tip. AV node ablation was simulated with an applied power of 5 W at 420 kHz at the distal 8 mm ablation electrode. The temperature at the catheter tip was 103.87 ° C after 5 s ablation time, 44.17 ° C from the catheter tip in the myocardium and 37.61 ° C at a distance of 2 mm. After 10 s, the temperature at the three measuring points described above was 107.33 ° C, 50.87 ° C, 40.05 ° C and after 15 seconds 118.42 ° C, 55.75 ° C and 42.13 ° C.
Conclusions: Virtual heart and electrode models as well as the simulations of electrical fields and temperature profiles allow the static and dynamic simulation of atrial synchronous BV stimulation and HF ablation at AF. The 3D simulation of the electrical field and temperature profile may be used to optimize the CRT and AF ablation.
Significance of new electrocardiographic parameters to improve cardiac resynchronization therapy
(2011)
Introduction: Oesophageal left heart electrogram (LHE) is a valuable tool providing electrocardiographic parameters for cardiac resynchronization therapy (CRT). It can be utilized to measure left ventricular (LVCD) and intra-leftventricular conduction delays (ILVCD) in heart failure patients to justify implantation of CRT systems. In the follow-up, LHE enables measurement of implant-related interatrial conduction times (IACT) which are the key intervals defining the hemodynamically optimal AV delay (AVD).
Methods: By TOSlim oesophageal electrode and Rostockfilter (Osypka AG, Rheinfelden, Germany), LHE was recorded in 39 heart failure patients (10f, 29m, 65±8yrs., QRS=163±21ms) after implantation of CRT systems according to guidelines. In position of maximal left ventricular deflection, LVCD and ILVCD were measured and compared with QRS width. In position of maximal left atrial deflection (LA), IACT was determined in VDD and DDD operation as interval As-LA and Ap-LA between atrial sense event (As) or stimulus (Ap), resp., and onset of LA. AVD was individualized using SAV =As-LA + 50ms for VDD and PAV=Ap-LA + 50ms for DDD operation.
Results: The CRT patients were characterized by minimal transoesophageal LVCD of 40ms but 73±20ms, at mean, ILVCD of 90±24ms and QRS/LVCD ratio of 2.4±0.6. The measured As-LA of 39±24ms and Ap-LA of 124±26ms resulted into SAV of 89±24ms and PAV of 174±26ms. In case of empirical AVD programming using 120ms for SAV and 180ms for PAV, the LHE revealed inverse sequences of LA and Vp in 4 patients (10%) during VDD and 13 patients (33%) in DDD pacing. In these patients, Vp preceded LA as IACT exceeded the programmed AVD.
Conclusion: Guideline indication of CRT systems is associated with LVCD of 40ms or more. Therefore, individual LVCD offers the minimal target interval that should be reached during left ventricular electrode placement to increase responder rate. Postoperatively, AV delay optimization respecting implant-related IACTs excludes adverse hemodynamic effects.
Serendipities in der Medizin
(2016)
Zufälle begleiten unser Leben. Auch bei wichtigen Entdeckungen und Entwicklungen in der Medizin spielt der „Zufall“ (engl. „serendipity“) eine Rolle. Hierzu gehören u. a. die Mendelschen Gesetze, die Ermittlung der menschlichen Chromosomenzahl, die Entdeckung der DNS durch Watson und Crick, der PAP-Test oder die Entdeckung der Röntgenstrahlung und der Radioaktivität. Aber auch und gerade in der Pharmakologie gibt es viele Beispiele für Serendipitäten. Einige gehen eng mit Zufällen bei der Entdeckung der Bakteriologie einher.
Verschiedenste Hersteller von Prothesen treiben die Entwicklungen in der Neuroprothetik immer weiter voran. Jedoch steigen dadurch nicht nur die Komplexität und die Funktionen einer solchen Prothese, sondern auch die Kosten. Oft wird vernachlässigt, dass ein einfaches Greifen meist schon ausreicht und damit oftmals viel mehr Personen geholfen werden kann als mit einer teuren Highend-Prothese.
Die vorliegende Masterthesis soll zeigen, dass es möglich ist, mit einfachen Mitteln einen funktionsfähigen bionischen Prototyp zu entwickeln. Die Steuerung funktioniert per Knopfdruck, Bewegungen werden automatisch ausgeführt.
Hierfür wurde auf der Rekonstruktion der ersten eisernen Hand des Götz von Berlichin-gen aufgebaut. Diese wurde mit günstiger und einfach beschaffbarer Elektronik verändert, damit die Prothese durch elektrische Motoren aktiv ansteuerbar ist. Das Modell wurde mit SolidWorks 2018 verändert. Die elektronischen Bauteile wurden über ein Arduino Board UNO R3 angesteuert, welcher die Schnittstelle zum Computer bildet.
Mice and rats make up 95% of all animals used in medical research and drug discovery and development. Monitoring of physiological functions such as ECG, blood pressure, and body temperature over the entire period of an experiment is often required. Restraining of the animals in order to obtain this data can cause great inconvenience. The use of telemetric systems solves this problem and provides more reliable results. However, these devices are mostly equipped with batteries, which limit the time of operation or they use passive power supplies, which affects the operating range. The semi-passive telemetric implant being presented is based on RFID technology and overcomes these obstacles. The device is inductively powered using the magnetic field of a common RFID reader device underneath the cage, but is also able to operate for several hours autonomously. Being independent from the battery capacity, it is possible to use the implant over a long period of time or to re-use the device several times in different animals, thus avoiding the disadvantages of existing systems and reducing the costs of purchase and refurbishment.
Introduction: Cardiac resynchronization therapy (CRT) with left ventricular (LV) pacing is an established therapy for heart failure (HF) patients (P) with ventricular desynchronisation and reduced LV ejection fraction (EF). The aim of this study was to test the utilization of the transesophageal approach to measure arterial pulse pressure (PP) during LV pacing and electrical interventricular conduction delay (IVCD), to better select patients for CRT.
Methods: 32 HF patients (age 64 ± 10 years; 5 females, 27 males) with New York Heart Association (NYHA) class 2.8 ± 0.6, 27 ± 11 % LV EF and 155 ± 35 ms QRS duration were analysed with semi-invasive left cardiac pacing and electrocardiography. Esophageal TO8 Osypka catheter of 10.5 F diameter was perorally applied to the esophagus and placed in the position of maximum left atrial (LA) deflection and maximum LV deflection to measure PP with VAT or D00 pacing modes.
Results: Temporary transesophageal LV pacing was possible with VAT mode (n=16) and D00 mode (n=16) in all patients. In 15 Δ-PP-responders, PP was higher during LV pacing on than LV pacing off (78.3 ± 26.6 versus 65.9 ± 23.7 mmHg, P < 0.001) and NYHA class improved from 3.1 ± 0.35 to 2.1 ± 0.35 (P < 0.001) during 29 ± 26 month biventricular (BV) pacing follow-up (6 Medtronic and 9 Boston BV pacing devices). In 17 Δ-PP-non-responders, PP was not higher during LV pacing on than LV pacing off (61.5 ± 23.9 versus 60.9 ± 23.5 mmHg, P = 0.066). IVCD was significant longer in Δ-PP-responders than in Δ-PP-non-responders (87 ± 33 ms versus 37± 29 ms, P < 0.001).
Conclusion: Semi-invasive transesophageale LA and LV pacing with D00 and VAT mode and LV electrogram recording may be useful techniques to predict CRT improvement.
Semi-invasive electromechanical target interval to guide left ventricular electrode placement
(2011)
Using guideline parameters for indication of cardiac resynchronization therapy (CRT), only about two thirds of the patients improve clinically. Unfortunately both, surface ECG and echo are uncertain to predict CRT response. To better characterize cardiac desynchronization in heart failure, interventricular (IVCD) and intra-leftventricular conduction delays (ILVCD) were measured by esophageal left ventricular electrogram (LVE). Recordings in 43 CRT patients (34m, 9f, age: 64.7 ± 9.5yrs) evidenced only weak correlation between IVCD and QRS of 0.53 and between ILVCD and QRS of 0.33. This demonstrated that QRS duration is not a reliable indicator of desynchronization. Therefore, the study resulted into development of LVE feature for a programmer with implant support device. It can be used interoperatively to guide the left ventricular electrode location in order to increase responder rate in CRT.
A wide range catalyst screening with noble metal and oxide catalysts for a metal–air battery with an aqueous alkaline electrolyte was carried out. Suitable catalysts reduce overpotentials during the charge and discharge process, and therefore improve the round-trip efficiency of the battery. In this case, the electrodes will be used as optimized cathodes for a future lithium–air battery with an aqueous alkaline electrolyte. Oxide catalysts were synthesized via atmospheric plasma spraying. The screening showed that IrO2, RuO2, La0.6Ca0.4Co3, Mn3O4, and Co3O4 are promising bi-functional catalysts. Considering the high price for the noble metal catalysts further investigations of the oxide catalysts were carried out to analyze their electrochemical behavior at varied temperatures, molarities, and in case of La1−x Ca x CoO3 a varying calcium content. Additionally all catalysts were tested in a longterm test to proof cyclability at varied molarities. Further investigations showed that Co3O4 seems to be the most promising bi-functional catalyst of the tested oxide catalysts. Furthermore, it was shown that a calcium content of x = 0.4 in LCCO has the best performance.
Background: R-wave synchronised atrial pacing is an effective temporary pacing
therapy in infants with postoperative junctional ectopic tachycardia. In the technique
currently used, adverse short or long intervals between atrial pacing and ventricular
sensing (AP–VS) may be observed during routine clinical practice.
Objectives: The aim of the study was to analyse outcomes of R-wave synchronised
atrial pacing and the relationship between maximum tracking rates and AP–VS
intervals.
Methods: Calculated AP–VS intervals were compared with those predicted by experienced
pediatric cardiologist.
Results: A maximum tracking rate (MTR) set 10 bpm higher than the heart rate (HR)
may result in undesirable short AP–VS intervals (minimum 83 ms). A MTR set 20 bpm
above the HR is the hemodynamically better choice (minimum 96 ms). Effects of either
setting on the AP–VS interval could not be predicted by experienced observers. In our
newly proposed technique the AP–VS interval approaches 95 ms for HR > 210 bpm
and 130 ms for HR < 130 bpm. The progression is linear and decreases strictly
(− 0.4 ms/bpm) between the two extreme levels.
Conclusions: Adjusting the AP–VS interval in the currently used technique is complex
and may imply unfavorable pacemaker settings. A new pacemaker design is advisable
to allow direct control of the AP–VS interval.
In dieser Bachelor Arbeit wird die Realisierung und messtechnische Analyse dreier Delta-Sigma-Modulatoren vorgestellt. Zwei der drei Modulatoren sind mit diskreten Bauteilen realisiert, ein dritter als integrierte Schaltung. Bei den diskret realisierten Modulatoren handelt es sich um Modulatoren 1. und 2. Ordnung, der als integrierte Schaltung verbaute Modulator ist ein Modulator 7. Ordnung.
Die Messdaten werden mithilfe eines Mikrocontrollers aufgezeichnet und am Computer mit MATLAB ausgewertet. Für die Auswertung der Modulatoren wird jeweils der Signalrauschabstand und die harmonische Verzerrung des Signals ermittelt. Zusätzlich wird bei jeder Messung eines Modulators das Spektrum des Signals ermittelt und dargestellt. Bei den beiden diskreten Modulatoren ergibt sich bei den Messungen ein Signalrauschabstand von 54 dB bis 56 dB, bei dem als integrierte Schaltung implementierten Delta-Sigma-Modulator wird ein Wert von 70 dB bis 76 dB erreicht. Für die harmonische Verzerrung der Signale wird beim Modulator 1. Ordnung ein Wert von 64 dB, beim Modulator 2. Ordnung 72 dB und beim 7. Ordnung 91 dB gemessen.
We report the fabrication and characterization of glucose-tolerant Raney-platinum cathodes for oxygen reduction in potentially implantable glucose fuel. Fabricated by extraction of aluminum from 1 μm thin platinum–aluminum bi-layers annealed at 300 °C, the novel cathodes show excellent resistance against hydrolytic and oxidative attack. This renders them superior over previous cathodes fabricated from hydrogel-bound catalyst particles. Annealing times of 60, 120, and 240 min result in approximately 400–550 nm thin porous films (roughness factors ∼100–150), which contain platinum and aluminum in a ratio of ∼9:1. Aluminum release during electrode operation can be expected to have no significant effect on physiological normal levels, which promises good biocompatibility. Annealing time has a distinct influence on the density of trenches formed in the cathode. Higher trench densities lead to lower electrode potentials in the presence of glucose. This suggests that glucose sensitivity is governed by mixed potential formation resulting from oxygen depletion within the trenches. During performance characterization the diffusion resistance to be expected from tissue capsule formation upon electrode implantation was taken into account by placing a membrane in front of the cathode. Despite the resulting limited oxygen supply, cathodes prepared by annealing for 60 min show more positive electrode potentials than previous cathodes fabricated from hydrogel-bound activated carbon. Compared to operation in phosphate buffered saline containing 3.0 mM glucose, a potential loss of approximately 120 mV occurs in artificial tissue fluid. This can be reduced to approximately 90 mV with a protective Nafion layer that is easily electro-coated onto the Raney-platinum film.
We present a novel fabrication route yielding Raney-platinum film electrodes intended as glucose oxidation anodes for potentially implantable fuel cells. Fabrication roots on thermal alloying of an extractable metal with bulk platinum at 200 °C for 48 h. In contrast to earlier works using carcinogenic nickel, we employ zinc as potentially biocompatible alloying partner. Microstructure analysis indicates that after removal of extractable zinc the porous Raney-platinum film (roughness factor ∼2700) consists predominantly of the Pt3Zn phase. Release of zinc during electrode operation can be expected to have no significant effect on physiological normal levels in blood and serum, which promises good biocompatibility. In contrast to previous anodes based on hydrogel-bound catalyst particles the novel anodes exhibit excellent resistance against hydrolytic and oxidative attack. Furthermore, they exhibit significantly lower polarization with up to approximately 100 mV more negative electrode potentials in the current density range relevant for fuel cell operation. The anodes’ amenability to surface modification with protective polymers is demonstrated by the exemplary application of an approximately 300 nm thin Nafion coating. This had only a marginal effect on the anode long-term stability and amino acid tolerance. While in physiological glucose solution after approximately 100 h of operation gradually increasing performance degradation occurs, rapid electrode polarization within 24 h is observed in artificial tissue fluid. Optimization approaches may include catalyst enhancement by adatom surface modification and the application of specifically designed protective polymers with controlled charge and mesh size.
This thesis deals with the implementation of the SUBSCALE algorithm in the Python programming language. First, the current state of research and the needs of the target group are considered. Then, the choice of language is decided based on the findings. On the basis of self-generated requirements, the implementation is carried out.
Finally, the code is evaluated for accuracy, consistency, and execution time, as well as its applicability in practice.
Since the implementation of the current work proved to be unconvincing, an approach is tested in which Python is used only as a front-end.
In the dual membrane fuel cell (DM-Cell), protons formed at the anode and oxygen ions formed at the cathode migrate through their respective dense electrolytes to react and form water in a porous composite layer called dual membrane (DM). The DM-Cell concept was experimentally proven (as detailed in Part I of this paper). To describe the electrochemical processes occurring in this novel fuel cell, a mathematical model has been developed which focuses on the DM as the characteristic feature of the DM-Cell. In the model, the porous composite DM is treated as a continuum medium characterized by effective macro-homogeneous properties. To simulate the polarization behavior of the DM-Cell, the potential distribution in the DM is related to the flux of protons and oxygen ions in the conducting phases by introducing kinetic and transport equations into charge balances. Since water pressure may affect the overall formation rate, water mass balances across the DM and transport equations are also considered. The satisfactory comparison with available experimental results suggests that the model provides sound indications on the effects of key design parameters and operating conditions on cell behavior and performance.
Introduction: Patient selection for cardiac resynchronization therapy (CRT) requires quantification of left ventricular conduction delay (LVCD). After implantation of biventricular pacing systems, individual AV delay (AVD) programming is essential to ensure hemodynamic response. To exclude adverse effects, AVD should exceed individual implant-related interatrial conduction times (IACT). As result of a pilot study, we proposed the development of a programmer-based transoesophageal left heart electrogram (LHE) recording to simplify both, LVCD and IACT measurement. This feature was implemented into the Biotronik ICS3000 programmer simultaneously with 3-channel surface ECG.
Methods: A 5F oesophageal electrode was perorally applied in 44 heart failure CRT-D patients (34m, 10f, 65±8 yrs., QRS=162±21ms). In position of maximum left ventricular deflection, oesophageal LVCD was measured between onsets of QRS in surface ECG and oesophageal left ventricular deflection. Then, in position of maximum left atrial deflection (LA), IACT in VDD operation (As-LA) was calculated by difference between programmed AV delay and the measured interval from onset of left atrial deflection to ventricular stimulus in the oesophageal electrogram. IACT in DDD operation (Ap-LA) was measured between atrial stimulus and LA..
Results: LVCD of the CRT patients was characterized by a minimum of 47ms with mean of 69±23ms. As-LA and Ap-LA were found to be 41±23ms and 125±25ms, resp., at mean. In 7 patients (15,9%), IACT measurement in DDD operation uncovered adverse AVD if left in factory settings. In this cases, Ap-LA exceeded the factory AVD. In 6 patients (13,6%), IACT in VDD operation was less than or equal 10ms indicating the need for short AVD.
Conclusion: Response to CRT requires distinct LVCD and AVD optimization. The ICS3000 oesophageal LHE feature can be utilized to measure LVCD in order to justify selection for CRT. IACT measurement simplifies AV delay optimization in patients with CRT systems irrespective of their make and model.
AV delay (AVD) optimization is mandatory in cardiac resynchronization (CRT) for heart failure. Several time consuming methods exist. We initialized development of left-atrial electrogram (LAE) feature for Biotronik ICS3000 programmer. It can be utilized to approximate optimal AV delay in CRT patients with pacing systems irrespective of make and model. Using this feature, we studied the share of interatrial conduction intervals (IACT) on individual echo AVD in 45 CRT patients (34m, 11f, mean age 69±6yrs.). The percentage of IACT on optimal echo AVD resulted in44.5±22.1% for VDD and 70.7±10.9% for DDD operation. In all patients, optimal echo AVDs exceeded the individual IACT by a duration of 52.5±33.3ms (p<0.001), at mean. Therefore, if AV delay optimization is not possible or not practicable in CRT patients, AVD should be approximated by individually measuring IACT and adding about 50ms.
In the work at hand, we combine a Private Information Retrieval (PIR) protocol with Somewhat Homomorphic Encryption (SHE) and use Searchable Encryption (SE) with the objective to provide security and confidentiality features for a third party cloud security audit. During the auditing process, a third party auditor will act on behalf of a cloud service user to validate the security requirements performed by a cloud service provider. Our concrete contribution consists of developing a PIR protocol which is proceeding directly on a log database of encrypted data and allowing to retrieve a sum or a product of multiple encrypted elements. Subsequently, we concretely apply our new form of PIR protocol to a cloud audit use case where searchable encryption is employed to allow additional confidentiality requirements to the privacy of the user. Exemplarily we are considering and evaluating an audit of client accesses to a controlled resource provided by a cloud service provider.
Economic dispatch is a well-known optimization problem in smart grid systems which aims at minimizing the total cost of power generation among generation units while maintaining some system constraints. Recently, some distributed consensus-based approaches have been proposed to replace traditional centralized calculation. However, existing approaches fail to protect privacy of individual units like cost function parameters, generator constraints, output power levels, etc. In this paper, we show an attack against an existing consensus-based economic dispatch algorithm from [16] assuming semi-honest non-colluding adversaries. Then we propose a simple solution by combining a secure sum protocol and the consensus-based economic dispatch algorithm that guarantees data privacy under the same attacker model. Our Privacy Preserving Economic Dispatch (PPED) protocol is information-theoretically secure.
Pressure dynamics in metal-oxygen (metal-air) batteries: a case study on sodium superoxide cells
(2014)
Electrochemical reactions in metal–oxygen batteries come along with the consumption or release of gaseous oxygen. We present a novel methodology for investigating electrode reactions and transport phenomena in metal–oxygen batteries by measuring the pressure dynamics in an enclosed gas reservoir above the oxygen electrode. The methodology is exemplified by a room-temperature sodium–oxygen battery forming sodium superoxide (NaO2) in an electrolyte of diethylene glycol dimethyl ether (diglyme) and sodium trifluoromethanesulfonate (NaOSO2CF3, NaOTf). The experiments are supported by microkinetic simulations with a one-dimensional multiphysics continuum model. During galvanostatic cycling over 30 cycles, a constant oxygen consumption/release rate is observed upon discharge/charge. The number of transferred electrons per oxygen molecule is calculated to 1.01 ± 0.02 and 1.03 ± 0.02 for discharge and charge, respectively, confirming the nature of the oxygen reaction product as superoxide O2–. The same ratio is observed in cyclic voltammetry experiments with low scan rate (<1 mV/s). However, at higher scan rates, the ratio increases as a result of oxygen transport limitations in the electrolyte. We introduce electrochemical pressure impedance spectroscopy (EPIS) for simultaneously analyzing current, voltage, and pressure of electrochemical cells. Pressure recording significantly increases the sensitivity of impedance toward oxygen transport properties of the porous electrode systems. In addition, we report experimental data on the diffusion coefficient and solubility of oxygen in electrolyte solutions as important parameters for the microkinetic models.
In this paper we present a model of the discharge of a lithium–oxygen battery with aqueous electrolyte. Lithium–oxygen batteries (Li–O2) have recently received great attention due to their large theoretical specific energy. Advantages of the aqueous design include the stability of the electrolyte, the long experience with gas diffusion electrodes (GDEs), and the solubility of the reaction product lithium hydroxide. However, competitive specific energies can only be obtained if the product is allowed to precipitate. Here we present a dynamic one-dimensional model of a Li–O2 battery including a GDE and precipitation of lithium hydroxide. The model is parameterized using experimental data from the literature. We demonstrate that GDEs remove power limitations due to slow oxygen transport in solutions and that lithium hydroxide tends to precipitate on the anode side. We discuss the system architecture to engineer where nucleation and growth predominantly occurs and to optimize for discharge capacity.
We report the use of the Raman spectral information of the chemical compound toluene C7H8 as a reference on the analysis of laboratory-prepared and commercially acquired gasoline-ethanol blends. The rate behavior of the characteristic Raman lines of toluene and gasoline has enabled the approximated quantification of this additive in commercial gasoline-ethanol mixtures. This rate behavior has been obtained from the Raman spectra of gasoline-ethanol blends with different proportions of toluene.
All these Raman spectra have been collected by using a self-designed, frequency precise and low-cost Fourier-transform Raman spectrometer (FT-Raman spectrometer) prototype. This FT-Raman prototype has helped to accurately confirm the frequency position of the main characteristic Raman lines of toluene present on the different gasoline-ethanol samples analyzed at smaller proportions than those commonly found in commercial gasoline-ethanol blends. The frequency accuracy validation has been performed by analyzing the same set of toluene samples with two additional state-of-the-art commercial FT-Raman devices. Additionally, the spectral information has been contrasted, with highly-correlated coefficients as a result, with the values of the standard Raman spectrum of toluene.
This paper evaluates the implementation of Medium Access Control (MAC) protocols suitable for massive access connectivity in 5G multi-service networks. The access protocol extends multi-packet detection receivers based on Physical Layer Network Coding (PLNC) decoding and Coded Random Access protocols considering practical aspects to implement one-stage MAC protocols for short packet communications in mMTC services. Extensions to enhance data delivery phase in two- stage protocols are also proposed. The assessment of the access protocols is extended under system level simulations where a suitable link to system interface characterization has been taken into account.
Electric arc furnaces (EAF) are complex industrial plants whose actual behavior depends upon numerous factors. Due to its energy intensive operation, the EAF process has always been subject to optimization efforts. For these reasons, several models have been proposed in literature to analyze and predict different modes of operation. Most of these models focused on the processes inside the vessel itself. The present paper introduces a dynamic, physics-based model of a complete EAF plant which consists of the four subsystems vessel, electric system, electrode regulation, and off-gas system. Furthermore the solid phase is not treated to be homogenous but a simple spatial discretization is employed. Hence it is possible to simulate the energy input by electric arcs and fossil fuel burners depending on the state of the melting progress. The model is implemented in object-oriented, equation-based language Modelica. The simulation results are compared to literature data.
PET and SPECT of Neurobiological Systems combines the expertise of renowned authors whose dedication to the development of novel probes and techniques for the investigation of neurobiological systems has achieved international recognition. Various aspects of neurotransmission in the brain are discussed, such as visualization and quantification of (more than 20 different) neuroreceptors, neuroinflammatory markers, transporters, and enzymes as well as neurotransmitter synthesis, β-amyloid deposition, cerebral blood flow, and the metabolic rate of glucose. The latest results in probe development are also detailed.
Most chapters are written jointly by radiochemists and nuclear medicine specialists to ensure a multidisciplinary approach. This state of the art compendium will be valuable to anyone in the field of clinical or preclinical neuroscience, from the radiochemist and radiologist/nuclear medicine specialist to the interested neurobiologist and general practitioner. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences. Other volumes focus on PET and SPECT in psychiatry and PET and SPECT in neurology".
PET and SPECT in Psychiatry
(2014)
PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects – such as suicide, sleep, eating disorders, and autism – are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.
PET and SPECT in Neurology
(2014)
PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.
Due to its numerous application fields and benefits, virtualization has become an interesting and attractive topic in computer and mobile systems, as it promises advantages for security and cost efficiency. However, it may bring additional performance overhead. Recently, CPU virtualization has become more popular for embedded platforms, where the performance overhead is especially critical. In this article, we present the measurements of the performance overhead of the two hypervisors Xen and Jailhouse on ARM processors in the context of the heavy load “Cpuburn-a8” application and compare it to a native Linux system running on ARM processors.
The need to measure basic aerosol parameters has increased dramatically in the last decade. This is due mainly to their harmful effect on the environment and on public health. Legislation requires that particle emissions and ambient levels, workplace particle concentrations and exposure to them are measured to confirm that the defined limits are met and the public is not exposed to harmful concentrations of aerosols.
Climate change and resultant scarcity of water are becoming major challenges for countries around the world. With the advent of Wireless Sensor Networks (WSN) in the last decade and a relatively new concept of Internet of Things (IoT), embedded systems developers are now working on designing control and automation systems that are lower in cost and more sustainable than the existing telemetry systems for monitoring. The Indus river basin in Pakistan has one of the world's largest irrigation systems and it is extremely challenging to design a low-cost embedded system for monitoring and control of waterways that can last for decades. In this paper, we present a hardware design and performance evaluation of a smart water metering solution that is IEEE 802.15.4-compliant. The results show that our hardware design is as powerful as the reference design, but allows for additional flexibility both in hardware and in firmware. The indigenously designed solution has a power added efficiency (PAE) of 24.7% that is expected to last for 351 and 814 days for nodes with and without a power amplifier (PA). Similarly, the results show that a broadband communication (434 MHz) over more than 3km can be supported, which is an important stepping stone for designing a complete coverage solution of large-scale waterways.
Proton Exchange Membrane Fuel Cells (PEMFC) are energy efficient and environmentally friendly alternatives to conventional energy conversion systems in many yet emerging applications. In order to enable prediction of their performance and durability, it is crucial to gain a deeper understanding of the relevant operation phenomena, e.g., electrochemistry, transport phenomena, thermodynamics as well as the mechanisms leading to the degradation of cell components. Achieving the goal of providing predictive tools to model PEMFC performance, durability and degradation is a challenging task requiring the development of detailed and realistic models reaching from the atomic/molecular scale over the meso scale of structures and materials up to components, stack and system level. In addition an appropriate way of coupling the different scales is required.
This review provides a comprehensive overview of the state of the art in modeling of PEMFC, covering all relevant scales from atomistic up to system level as well as the coupling between these scales. Furthermore, it focuses on the modeling of PEMFC degradation mechanisms and on the coupling between performance and degradation models.
Recently, the demand for scalable, efficient and accurate Indoor Positioning Systems (IPS) has seen a rising trend due to their utility in providing Location Based Services (LBS). Visible Light Communication (VLC) based IPS designs, VLC-IPS, leverage Light Emitting Diodes (LEDs) in indoor environments for localization. Among VLC-based designs, Time Difference of Arrival (TDOA) based techniques are shown to provide very low errors in the relative position of receivers. Our considered system consists of five LEDs that act as transmitters and a single receiver (photodiode or image sensor in smart phone) whose position coordinates in an indoor environment are to be determined. As a performance criterion, Cramer Rao Lower Bound (CRLB) is derived for range estimations and the impact of various factors, such as, LED transmission frequency, position of reference LED light, and the number of LED lights, on localization accuracy has been studied. Simulation results show that depending on the optimal values of these factors, location estimation on the order of few centimeters can be realistically achieved.
Finding clusters in high dimensional data is a challenging research problem. Subspace clustering algorithms aim to find clusters in all possible subspaces of the dataset where, a subspace is the subset of dimensions of the data. But exponential increase in the number of subspaces with the dimensionality of data renders most of the algorithms inefficient as well as ineffective. Moreover, these algorithms have ingrained data dependency in the clustering process, thus, parallelization becomes difficult and inefficient. SUBSCALE is a recent subspace clustering algorithm which is scalable with the dimensions and contains independent processing steps which can be exploited through parallelism. In this paper, we aim to leverage, firstly, the computational power of widely available multi-core processors to improve the runtime performance of the SUBSCALE algorithm. The experimental evaluation has shown linear speedup. Secondly, we are developing an approach using graphics processing units (GPUs) for fine-grained data parallelism to accelerate the computation further. First tests of the GPU implementation show very promising results.
Die in dieser Arbeit erzielten Ergebnisse zur Optimierung der Parameter zur Registrierung elektrisch evozierter Hirnstammpotenziale mit den beiden ERA-Messsystemen Eclipse EP25 und Synergy EDX dienen als Grundlage für die eBERA Untersuchungen. Betrachtet wurden besonders hierbei die Stimulati-onsart, Filtereinstellungen und Mittelungsoptionen.
Bei allen Messungen mit beiden Systemen, Eclipse EP25 und Synergy EDX, wird eine contralaterale Ableitung nahegelegt.
Eine zu empfehlende Filtereinstellung der Hochpassfilter und Tiefpassfilter zur Potenzialregistrierung mittels eBERA ist 0,2 Hz / 3000 Hz bei der Synergy und 33 Hz / 3000 Hz bei der Eclipse EP25. Bei Vorliegen tieffrequenter Einstreuun-gen ist eine Erhöhung der Grenzfrequenz des Hochpassfilters auf 100 Hz zu empfehlen.
Bei der Wahl der Stimulationsart hat sich die alternierende als die beste her-ausgestellt. Dies belegen sowohl die in den Ergebnissen gemessenen Potentia-le als auch Messungen von Kollegen (Steffens, 2016).
Die Mittelungsoption „bayesian weighting“ bei der Eclipse EP25 hat sich bei der eBERA Messung als nicht sehr hilfreich erwiesen. Bei der Synergy EDX hat die Einstellung „Mittel“ im Vergleich zu „Gewichtet“ die besseren Ergebnisse erzielt. Daher wird diese Wahl empfohlen, falls mit diesem System gemessen wird. Weitere weniger einflussreiche Einstellungen werden im Anhang C. „Optimierte Parameter beider Messsysteme“ aufgelistet.
The importance of obtaining simultaneous particle size and concentration values has grown up with continuing discussion of the health effects, of internal combustion engine generated particulate emissions and in particular of Diesel soot emissions. In the present work an aerosol measurement system is described that delivers information about particle size and concentration directly from the undiluted exhaust gas.
Using three laser diodes of different wavelengths which form one parallel light beam, each spectral attenuation is analysed by a single detector and the particle diameter and concentration is evaluated by the use of the Mie theory and shown on-line at a frequency of 1 Hz. The system includes an optical long-path-cell (White principle) with an adjustable path length from 2.5 to 15 m, which allows the analysis within a broad concentration range.
On-line measurements of the particulate emissions in the hot, undiluted exhaust of Diesel engines are presented under stationary and transient engine’s load conditions. Mean particle diameters well below 100 nm are detected for modern Diesel engines. The measured particle concentration corresponds excellently with the traditional gravimetrical measurements of the diluted exhaust. Additionally, measurements of particle emissions (mostly condensed hydricarbons) from a two-stroke engine are presented and discussed.
In the last decade, IPv6 over Low power Wireless Personal Area Networks (IEEE802.15.4), also known as 6LoWPAN, has well evolved as a primary contender for short range wireless communications and holds the promise of an Internet of Things, which is completely based on the Internet Protocol. The authors' team has developed a 6LoWPAN protocol stack in C language, the stack without the necessity to use a specific design environment or operating system. It is highly flexible, modular, and portable and can be enhanced by several interesting modules, like a Wake-On-Radio-(WOR) MAC layer or a TLS1.2 based security sublayer. The stack is made available as open source at https://github.com/hso-esk/emb6. It was extensively tested on the Automated Physical Testbed (APTB) for Wireless Systems, which is available in the authors' lab and allows a flexible setup and full control of arbitrary topologies. The results of the measurements demonstrate a very good stability and short-term with long-term performance also under dynamic conditions.
Soccer simulation league is one of the founding leagues of RoboCup. In this paper we discuss the past, present and planned future achievements and changes. Also we summarize the connections and inter-league achievements of this league and provide an overview of the community contributions that made this league successful.
Oesophageal Electrode Probe and Device for Cardiological Treatment and/or Diagnosis (EP3706626A1)
(2020)
The invention relates to an oesophageal electrode probe (10) for bioimpedance measurement and/or for neurostimulation; a device (100) for transoesophageal cardiological treatment and/or cardiological diagnosis; and a method for the open-loop or closed-loop control of a cardiac catheter ablation device and/or a cardiac, circulatory and/or respiratory support device. The oesophageal electrode probe comprises a bioimpedance measuring device for measuring the bioimpedance of at least one part of the tissue surrounding the oesophageal electrode probe. The bioimpedance device comprises at least one first and one second electrode, wherein the at least one first electrode (12A) is arranged on a side (14) of the oesophageal electrode probe facing towards the heart and the at least one second electrode (12B) is arranged on a side (16) of the oesophageal electrode probe facing away from the heart. The device (100) comprises the oesophageal electrode probe (10) and a control and/or evaluation device (30), which is configured for receiving a first bioimpedance measurement signal from the at least one first electrode (12A) and a second bioimpedance measurement signal from the at least one second electrode (12B), and comparing same, and generating a control signal on the basis of the comparison. The control signal can be a signal for the open-loop or closed-loop control of a cardiac catheter ablation device and/or a cardiac, circulatory and/or respiratory support device.
In the brain-cell microenvironment, diffusion plays an important role: apart from delivering glucose and oxygen from the vascular system to brain cells, it also moves informational substances between cells. The brain is an extremely complex structure of interwoven, intercommunicating cells, but recent theoretical and experimental works showed that the classical laws of diffusion, cast in the framework of porous media theory, can deliver an accurate quantitative description of the way molecules are transported through this tissue. The mathematical modeling and the numerical simulations are successfully applied in the investigation of diffusion processes in tissues, replacing the costly laboratory investigations. Nevertheless, modeling must rely on highly accurate information regarding the main parameters (tortuosity, volume fraction) which characterize the tissue, obtained by structural and functional imaging. The usual techniques to measure the diffusion mechanism in brain tissue are the radiotracer method, the real time iontophoretic method and integrative optical imaging using fluorescence microscopy. A promising technique for obtaining the values for characteristic parameters of the transport equation is the direct optical investigation using optical fibers. The analysis of these parameters also reveals how the local geometry of the brain changes with time or under pathological conditions. This paper presents a set of computations concerning the mass transport inside the brain tissue, for different types of cells. By measuring the time evolution of the concentration profile of an injected substance and using suitable fitting procedures, the main parameters characterizing the tissue can be determined. This type of analysis could be an important tool in understanding the functional mechanisms of effective drug delivery in complex structures such as the brain tissue. It also offers possibilities to realize optical imaging methods for in vitro and in vivo measurements using optical fibers. The model also may help in radiotracer biomarker models for the understanding of the mechanism of action of new chemical entities.
Concussions in sports and during recreational activities are a major source of traumatic brain injury in our society. This is mainly relevant in adolescence and young adulthood, where the annual rate of diagnosed concussions is increasing from year to year. Contact sports (e.g., ice hockey, American football, or boxing) are especially exposed to repeated concussions. While most of the athletes recover fully from the trauma, some experience a variety of symptoms including headache, fatigue, dizziness, anxiety, abnormal balance and postural instability, impaired memory, or other cognitive deficits. Moreover, there is growing evidence regarding clinical and neuropathological consequences of repetitive concussions, which are also linked to an increased risk for depression and Alzheimer’s disease or the development of chronic traumatic encephalopathy. With little contribution of conventional structural imaging (computed tomography (CT) or magnetic resonance imaging (MRI)) to the evaluation of concussion, nuclear imaging techniques (i.e., positron emission tomography (PET) and single-photon emission computed tomography (SPECT)) are in a favorable position to provide reliable tools for a better understanding of the pathophysiology and the clinical evaluation of athletes suffering a concussion.
A theoretical description is given for the propagation of surface acoustic wave pulses in anisotropic elastic media subject to the influence of nonlinearity. On the basis of nonlinear elasticity theory, an evolution equation is presented for the surface slope or the longitudinal surface velocity associated with an acoustic pulse. It contains a non-local nonlinearity, characterized by a kernel that strongly varies from one propagation geometry to another due to the anisotropy of the substrate. It governs pulse shape evolution in homogeneous halfspaces and the shapes of solitary surface pulses that exist in coated substrates. The theory describing nonlinear Rayleigh-type surface acoustic waves is extended in a straightforward way to surface waves that are localized at a one-dimensional acoustic waveguide like elastic wedges.
In this paper we present the implementation of a model-predictive controller (MPC) for real-time control of a cable-robot-based motion simulator. The controller computes control inputs such that a desired acceleration and angular velocity at a defined point in simulator’s cabin are tracked while satisfying constraints imposed by working space and allowed cable forces of the robot. In order to fully use the simulator capabilities, we propose an approach that includes the motion platform actuation in the MPC model. The tracking performance and computation time of the algorithm are investigated in computer simulations. Furthermore, for motion simulation scenarios where the reference trajectories are not known beforehand, we derive an estimate on how much motion simulation fidelity can maximally be improved by any reference prediction scheme compared to the case when no prediction scheme is applied.
This work describes a camera-based method for the calibration of optical See-Through Glasses (STGs). A new calibration technique is introduced for calibrating every single display pixel of the STGs in order to overcome the disadvantages of a parametric model. A non-parametric model compared to the parametric one has the advantage that it can also map arbitrary distortions. The new generation of STGs using waveguide-based displays [5] will have higher arbitrary distortions due to the characteristics of their optics. First tests show better accuracies than in previous works. By using cameras which are placed behind the displays of the STGs, no error prone user interaction is necessary. It is shown that a high accuracy tracking device is not necessary for a good calibration. A camera mounted rigidly on the STGs is used to find the relations between the system components. Furthermore, this work elaborates on the necessity of a second subsequent calibration step which adapts the STGs to a specific user. First tests prove the theory that this subsequent step is necessary.
This work describes a non-parametric camera-based method for the calibration of Optical See-Through Glasses (OSTG). Existing works model the optical system through perspective projection and parametric functions. In the border areas of the displays such models are often inadequate. Moreover, rigid calibration patterns, that produce only a small amount of non-equidistant point correspondences, are used. In order to overcome these disadvantages every single display pixel is calibrated individually. The error prone user interaction is avoided by using cameras placed behind the displays of the OSTG. The displays show a shifting pattern that is used to calculate the pixels' locations. A camera mounted rigidly on the OSTG is used to find the relations between the system components. The obtained results show better accuracies than in previous works and prove that a second calibration step for user adaptation is necessary for high accuracy applications.
In this paper, we establish a simple model for the exchange of messages in a vehicular network and we consider fundamental limits on the achievable data rate. For a vehicular network, the exchange of data with other nearby vehicles is particularly important for traffic safety, e.g. for collision avoidance, but also for cooperative applications like platooning. These use cases are currently addressed by standards building on IEEE 802.11p, namely ITS-G5 and DSRC (dedicated short range communication), which encounter saturation problems at high vehicle densities. For this reason, we take a step back and ask for the fundamental limits for the common data rate in a vehicular network. After defining a simple single-lane model and the corresponding capacity limits for some basic multiple- access schemes, we present results for a more realistic setting. For both scenarios, non-orthogonal multiple-access (NOMA) yields the best results.
In this paper, we present a frame synchronization method which consists of the non-orthogonal superposition of a synchronization sequence and the data. We derive the optimum detection criterion and compare it to the classical sequential concatenation of synchronization and data sequences. Computer simulations confirm the benefits of the non-orthogonal allocation for the case of short frames, which makes this technique particularly suited for the increasingly important regime of low latency and ultra- reliable communication.
This paper presents new measurements of a bronze cast from the right hand of the famous Italian violin virtuoso Nicolò Paganini (1782-1840). These are compared to anthropometric standard values. In addition, detailed dorsal and palmar views of the cast are shown. With a middle finger length of 75 mm, the palm width is 60 mm and the hand length 152 mm, which is significantly below the 5% percentile of today's standard values. Also the finger length index (0.55), the ratio of finger length to palm length (0.98) and the ratio of finger length to palm width (1.25) are significantly above normal limits. Hence, Paganini had abnormal hand measurements with a very small palm and relatively "long" fingers. This remarkable constellation, among others, could have been advantageous for his amazing skills as a violinist.
Die Verwendung von Kameras als Messmittel für medizinische Anwendungen setzt deren präzise Kalibrierung voraus. Gängige Verfahren modellieren die Abbildungseigenschaften einer Kamera mittels perspektivischer Projektion und parametrisierter Funktionen zur Beschreibung von Linsenverzerrung. In den Randbereichen des Kamerabildes sind diese Modelle oft unzureichend. Außerdem bedingt die Verwendung starrer Kalibriermuster eine in der Regel kleine Anzahl an nicht gleichmäßig verteilten Punktkorrespondenzen zur Bestimmung der Modellparameter. In der vorliegenden Arbeit wird ein vollkommen neues und nicht auf Modellen basierendes Kalibrierverfahren vorgestellt, bei dem jedes Kamerapixel unabhängig von jedem anderen kalibriert wird.
NEXCODE is a project promoted by the European Space Agency aimed at research design development and demonstration of a receiver chain for telecomm and links in space missions including the presence of new short low-density parity-check codes for error correction. These codes have excellent performance from the error rate viewpoint but also put new challenges as regards synchronization issues and implementation. In this paper after a short review of the results obtained through numerical simulations we present an overview of the breadboard designed for practical testing and the test-plan proposed for the verification of the breadboard and the validation of the new codes and novel synchronization techniques under relevant operation conditions.
The flow field-flow fractionation (FIFFF) technique is a promising method for separating and analysing particles and large size macromolecules from a few nanometers to approximately 50 μm. A new fractionation channel is described featuring well defined flow conditions even for low channel heights with convenient assembling and operations features. The application of the new flow field-flow fractionation channel is proved by the analysis of pigments and other small particles of technical interest in the submicrometer range. The experimental results including multimodal size distributions are presented and discussed.
In dieser Thesis wird die Visualisierung der Stammdaten der MARKANT Handels und
Service GmbH (MARKANT) überarbeitet. Zu Beginn wird auf die Firma MARKANT,
die aktuelle Lösung der Visualisierung und die daraus resultierenden Probleme eingegangen.
In der Thesis wird zunächst ein generisches Diagramm erstellt, welches Daten,
die eine hierarchische Ordnung haben, zeichnet. Darauf aufbauend soll als Beispiel, das
Organigramm der Firma MARKANT, mit allen Anforderungen, umgesetzt werden.
Um das Ziel zu erreichen, wird eine Marktübersicht eingeholt und die Frameworks
verglichen. Nachdem eine engere Auswahl getroffen ist, sollen die Frameworks hinsichtlich
der Visualisierung genauer evaluiert werden.
Nach der Wahl des Frameworks wird eine Konzeption erstellt, bei der auf einen neuen
Technologiestack, sowie auf die Bedienbarkeit des Diagrammes durch den Endanwender
eingegangen wird.
Anhand der erstellten Konzeption werden die verschiedenen Funktionen des Diagrammes
implementiert. Ein neuer Stack wird aufgebaut und an das System der Firma
MARKANT angepasst.
Abschließend zeigt ein Vergleich zwischen der alten und der neuen Visualisierung auf,
was in der Thesis erreicht wurde.