Refine
Year of publication
- 2015 (70) (remove)
Document Type
- Conference Proceeding (38)
- Article (reviewed) (12)
- Article (unreviewed) (8)
- Part of a Book (5)
- Patent (4)
- Book (3)
Conference Type
- Konferenzartikel (30)
- Konferenz-Abstract (6)
- Sonstiges (2)
Is part of the Bibliography
- yes (70) (remove)
Keywords
- Applikation (5)
- Abtragung (3)
- Eingebettetes System (3)
- Herz (3)
- Kommunikation (3)
- Physik (3)
- Raman-Spektroskopie (3)
- Datensicherung (2)
- Funktechnik (2)
- Herzrhythmusstörung (2)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (70) (remove)
Open Access
- Closed Access (32)
- Open Access (22)
- Bronze (6)
The demand of wireless solutions in industrial applications increases since the early nineties. This trend is not only ongoing, it is further pushed by developments in the area of software stacks like the latest Bluetooth Low Energy Stack. It is also pushed by new chip-designs and powerful and highly integrated electronic hardware. The acceptance of wireless technologies as a possible solution for industrial applications, has overcome the entry barrier [1]. The first step to see wireless as standard for many industrial applications is almost accomplished. Nevertheless there is nearly none acceptance of wireless technology for Safety applications. One highly challenging and demanding requirement is still unsolved: The aspect safety and robustness. Those topics have been addressed in many cases but always in a similar manner. WirelessHART as an example addresses this topic with redundant so called multiple propagation paths and frequency hopping to handle with interferences and loss of network participants. So far the pure peer to peer link is rarely investigated and there are less safety solutions available. One product called LoRa™ can be seen as one possible solution to address this lack of safety within wireless links. This paper focuses on the safety performance evaluation of a modem-chip-design. The use of diverse and redundant wireless technologies like LoRa can lead to an increase acceptance of wireless in safety applications. Many measurements in real industrial application have been carried out to be able to benchmark the new chip in terms of the safety aspects. The content of this research results can help to raise the level of confidence in wireless. In this paper, the term “safety” is used for data transmission reliability.
In this paper an RFID/NFC (ISO 15693 standard) based inductively powered passive SoC (system on chip) for biomedical applications is presented. A brief overview of the system design, layout techniques and verification method is dis-cussed here. The SoC includes an integrated 32 bit microcontroller, sensor interface circuit, analog to digital converter, integrated RAM, ROM and some other peripherals required for the complete passive operation. The entire chip is realized in CMOS 0.18 μm technology with a chip area of 1.52mm x 3.24 mm.
This paper presents a practice and science orientated education approach for freshman students of interdisciplinary bachelor engineering degree programs. This approach is meant to enhance the motivation and success of freshman students during their whole study. The education approach is called Fit4PracSis (Fit for Practice and Sciences) It was started to develop, set up and establish an education approach, which is building a relationship to students' future profession and to scientific working during the introductory study phase. The freshman students will be trained early in important skills, which are necessary for achieving the final degree successfully and handling of future business and research activities.
The aim of this research work was to develop a boiler model with few parameters required for energy planning. The showcase considered for this work was the boiler system of the energy center at Offenburg University of Applied Sciences. A grey box model of the boiler was developed systematically starting from model abstraction, simplification, model break-down and to the use of empirical correlations wherever necessary to describe the intermediate effects along with the use of information from manufacturer’s specification in order to reduce parameters. This strategy had resulted in a boiler model with only 6 parameters, namely, nominal burner capacity, water gallery capacity, air ratio, heat capacity of wall, thermal conductance on flue gas and hot water side. Most of these parameters can be obtained through the information available in the spec sheets and thus an energy planner will be able to parameterize the model with low effort. The model was validated with the monitored data of the showcase. It was tested for the start-up, shut-down behavior and the effect of storage.
Environmental Monitoring is an attractive application field for Wireless Sensor Network (WSN). Water Level Monitoring helps to increase the efficiency of water distribution and management. In Pakistan, the world’s largest irrigation system covers 90.000 km of channels which needs to be monitored and managed on different levels. Especially the sensor systems for the small distribution channels need to be low energy and low cost. The distribution presents a technical solution for a communication system which is developed in a research project being co-funded by German Academic Exchange Service (DAAD). The communication module is based on IEEE-802.15.4 transceivers which are enhanced through Wake-On-Radio (WOR) to combine low-energy and real-time behavior. On higher layers, IPv6 (6LoWPAN) and corresponding routing protocols like Routing Protocol for Low power and Lossy Networks (RPL) can extend range of the network. The data are stored in a database and can be viewed online via a web interface. Of course, also automatic data analysis can be performed.
We report the use of the Raman spectral information of the chemical compound toluene C7H8 as a reference on the analysis of laboratory-prepared and commercially acquired gasoline-ethanol blends. The rate behavior of the characteristic Raman lines of toluene and gasoline has enabled the approximated quantification of this additive in commercial gasoline-ethanol mixtures. This rate behavior has been obtained from the Raman spectra of gasoline-ethanol blends with different proportions of toluene.
All these Raman spectra have been collected by using a self-designed, frequency precise and low-cost Fourier-transform Raman spectrometer (FT-Raman spectrometer) prototype. This FT-Raman prototype has helped to accurately confirm the frequency position of the main characteristic Raman lines of toluene present on the different gasoline-ethanol samples analyzed at smaller proportions than those commonly found in commercial gasoline-ethanol blends. The frequency accuracy validation has been performed by analyzing the same set of toluene samples with two additional state-of-the-art commercial FT-Raman devices. Additionally, the spectral information has been contrasted, with highly-correlated coefficients as a result, with the values of the standard Raman spectrum of toluene.
La industria del bacanora en Sonora, México, enfrenta la influencia de una compleja red de factores culturales, tecnológicos, económicos y legales que inhiben su desarrollo. Ello ocurre pese al esfuerzo institucional por radicar un marco normativo que elimine la práctica de los métodos informales de elaboración que derivan en calidades heterogéneas de licor. El conseguirlo se complica ante la dificultad que enfrentan los actores de esta industria para implementar prácticas efectivas de verificación de las normas vigentes en los confines de la geografía de la Denominación de Origen. En este documento se describe el uso de un prototipo de espectrómetro Raman por transformada de Fourier para analizar cualitativamente muestras desconocidas de bacanora. Este dispositivo se construyó con el uso de un interferómetro Michelson convencional, un contador de fotones de diseño propio y un foto-detector de referencia. Los resultados del trabajo confirman que dada su naturaleza de diseño y construcción, este instrumento de medición y su efectiva técnica de operación a bajo costo, constituye una alternativa viable, adaptable fácilmente a las necesidades de los actores productivos e institucionales, para asistirlos en la elaboración de bacanora y a la verificación de su calidad conforme a los criterios de la normatividad.
The Raman spectra from the chemical compounds toluene and cyclohexane obtained using a Fourier Transform (FT)-Raman spectrometer prototype have been contrasted with the Raman spectra of these same materials collected with two different commercial FT-Raman devices. The FT-Raman spectrometer consist of a Michelson interferometer, a self-designed photon counter and a reference photo-detector. The evaluation methodology of the spectral information, contrary to the commercial devices that commonly use the zero-crossing method, is carried out by re-sampling the Raman scattering and by accurately extracting the optical path information of the Michelson interferometer. The FTRaman arrangement has been built using conventional parts without disregarding the spectral frequency precision that usually such a FTRaman instruments deliver. No additional complex hardware components or costly software modules have been included in this FT-Raman device. The main Raman lines from the spectra obtained with the three FT-Raman devices have been compared with the Raman lines from the standard Raman spectra of these two materials. The values obtained using the FT-Raman spectrometer prototype have shown a frequency accuracy comparable to that obtained with the commercial devices without facing the need for a large investment. Although the proposed FT-Raman prototype cannot be directly compared to the last generation of FT-Raman spectrometers from the commercial manufacturers, such a device could give an opportunity to users that require high frequency precision in their spectral analysis and are provided with rather scarce resources.
Wireless sensor networks have recently found their way into a wide range of applications among which environmental monitoring system has attracted increasing interests of researchers. Such monitoring applications, in general, don way into a wide range of applications among which environmental monitoring system has attracted increasing interests of researc latency requirements regarding to the energy efficiency. Also a challenge of this application is the network topology as the application should be able to be deployed in very large scale. Nevertheless low power consumption of the devices making up the network must be on focus in order to maximize the lifetime of the whole system. These devices are usually battery-powered and spend most of their energy budget on radio transceiver module. A so-called Wake-On-Radio (WoR) technology can be used to achieve a reasonable balance among power consumption, range, complexity and response time. In this paper, some designs for integration of WOR into IEEE 802.1.5.4 are to be discussed, providing an overview of trade-offs in energy consumption while deploying the WoR schemes in a monitoring system.
Extended Performance Measurements of Scalable 6LoWPAN Networks in an Automated Physical Testbed
(2015)
IPv6 over Low power Wireless Personal Area Networks, also known as 6LoWPAN, is becoming more and more a de facto standard for such communications for the Internet of Things, be it in the field of home and building automation, of industrial and process automation, or of smart metering and environmental monitoring. For all of these applications, scalability is a major precondition, as the complexity of the networks continuously increase. To maintain this growing amount of connected nodes a various 6LoWPAN implementations are available. One of the mentioned was developed by the authors' team and was tested on an Automated Physical Testbed for Wireless Systems at the Laboratory Embedded Systems and Communication Electronics of Offenburg University of Applied Sciences, which allows the flexible setup and full control of arbitrary topologies. It also supports time-varying topologies and thus helps to measure performance of the RPL implementation. The results of the measurements prove an excellent stability and a very good short and long-term performance also under dynamic conditions. In all measurements, there is an advantage of minimum 10% with regard to the average times, like global repair time; but the advantage with reagr to average values can reach up to 30%. Moreover, it can be proven that the performance predictions from other papers are consistent with the executed real-life implementations.
Der Studienbeginn wird an der Hochschule Offenburg durch Vorbereitungskurse, sogenannte Brückenkurse, unterstützt. Wir stellen vorläufige Ergebnisse beim Einsatz von Smartphones und Tablets im Rahmen des Physik-Brückenkurses vor, bei dem die Studenten Hilfen zum selbständigen Üben durch eine App erhalten. Durch die Überarbeitung des Kurses und den Einsatz der App konnte der Teilnehmerschwund verringert werden. Die Evaluationsergebnisse bestätigen eine hohe Akzeptanz der Neuerungen seitens der Studierenden. Erste Auswertungen von Ein- und Ausgangstests deuten darauf hin, dass durch den Brückenkurs eine Angleichung der Vorkenntnisse der Studienanfänger erreicht wird, da Teilnehmer mit geringeren Vorkenntnissen tendenziell einen größeren Lernfortschritt erreichen. Durch unterschiedliche Schwierigkeitsstufen und selbstregulierte Übungsphasen in individuellem Tempo können aber auch die Erfordernisse der stärkeren Teilnehmer angemessen berücksichtigt werden.
Lithium-oxygen cells with organic electrolyte suffer high overpotentials during charge, indicating asymmetric charge/discharge reaction mechanisms. We present a multi-physics dynamic modeling and simulation study of the Li/O2 cell cycling behavior. We present three different multi-step mechanisms of the 2 Li + O2 ⇄ Li2O2 cell reaction, (A) a reversible 5-step mechanism, (B) a partially irreversible 6-step mechanism, and (C) a partially irreversible 8-step mechanism that includes reactions of a redox mediator. Model predictions are compared to experimental galvanostatic cycling data of Swagelok cells without and with 2,2,6,6-tetramethylpiperidinyloxyl (TEMPO) as redox mediator. All mechanisms are able to predict the discharge behavior in good agreement to the experimental results. The experimentally observed high charge overpotentials as well as their reduction by using a redox mediator can be qualitatively reproduced with the irreversible reaction mechanisms. However, the particular shape of the experimental charge curve with continuously increasing charge overpotential cannot be reproduced with the present mechanisms.
Chronic insomnia is defined by difficulties in falling asleep, maintaining sleep, and early morning awakening, and is coupled with daytime consequences such as fatigue, attention deficits, and mood instability. These symptoms persist over a period of at least 3 months (Diagnostic and Statistical Manual 5 criteria). Chronic insomnia can be a symptom of many medical, neurological, and mental disorders. As a disorder, it incurs substantial health-care and occupational costs, and poses substantial risks for the development of cardiovascular and mental disorders, including cognitive deficits. Family and twin studies confirm that chronic insomnia can have a genetic component (heritability coefficients between 42% and 57%), whereas the investigation of autonomous and central nervous system parameters has identified hyperarousal as a final common pathway of the pathophysiology, implicating an imbalance of sleep–wake regulation consisting of either overactivity of the arousal systems, hypoactivity of the sleep-inducing systems, or both. Insomnia treatments include benzodiazepines, benzodiazepine-receptor agonists, and cognitive behavioural therapy. Treatments currently under investigation include transcranial magnetic or electrical brain stimulation, and novel methods to deliver psychological interventions.