Refine
Year of publication
- 2012 (42) (remove)
Document Type
- Conference Proceeding (42) (remove)
Conference Type
- Konferenzartikel (30)
- Konferenz-Abstract (8)
- Konferenzband (2)
- Konferenz-Poster (1)
- Sonstiges (1)
Keywords
- Mikroelektronik (2)
- RoboCup (2)
- Signaltechnik (2)
- 2D-TLC (1)
- Aircraft (1)
- Attenuation (1)
- BLE (1)
- Batterie (1)
- Brennstoffzelle (1)
- Bruchmechanik (1)
- Collaborative learning (1)
- Communication networks (1)
- Couplings (1)
- DVB-T (1)
- Device independency (1)
- Diode-array detection (1)
- Elektrokardiogramm (1)
- Faserstoff (1)
- HPTLC (1)
- Herzmuskelkrankheit (1)
- Herzschrittmacher (1)
- In-flight entertainment (1)
- Internet Overlay networks (1)
- Kerbe (1)
- Knowledge sharing (1)
- Language acquisition (1)
- Modell (1)
- Network topology (1)
- PKI (1)
- Peer to peer computing (1)
- Rahmen (1)
- Rails (1)
- Routing (1)
- Smart grids (1)
- Student activities (1)
- Sulphonamides (1)
- TLC (1)
- Telemetrie (1)
- Temperaturmessung (1)
- Thermische Solaranlage (1)
- TinyOS (1)
- Transceivers (1)
- User generated content (1)
- User interface (1)
- Virtual private networks (1)
- Virtual reality (1)
- Wireless M-Bus (1)
- car2x networks (1)
- energy harvesting (1)
- guided waves (1)
- high performance (1)
- low power wireless (1)
- model driven design (1)
- privacy (1)
- security (1)
- smart metering (1)
- wireless comunication (1)
- wireless sensor (1)
- Überwachung (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (29)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (9)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (3)
- CRT - Campus Research & Transfer (2)
- WLRI - Work-Life Robotics Institute (2)
- Fakultät Wirtschaft (W) (1)
- INES - Institut für nachhaltige Energiesysteme (1)
Open Access
- Open Access (20)
- Closed Access (11)
- Closed (10)
- Bronze (6)
The research project Ko-TAG [2], as part of the research initiative Ko-FAS [1], funded by the German Ministry of Economics and Technologies (BMWi), deals with the development of a wireless cooperative sensor system that shall pro-vide a benefit to current driver assistance systems (DAS) and traffic safety applications (TSA). The system’s primary function is the localization of vulnerable road users (VRU) e.g. pedestrians and powered two-wheelers, using communication signals, but can also serve as pre-crash (surround) safety system among vehicles. The main difference of this project, compared to previous ones that dealt with this topic, e.g. the AMULETT project, is an underlying FPGA based Hardware-Software co-design. The platform drives a real-time capable communication protocol that enables highly scalable network topologies fulfilling the hard real-time requirements of the single localization processes. Additionally it allows the exchange of further data (e.g. sensor data) to support the accident pre-diction process and the channel arbitration, and thus supports true cooperative sensing. This paper gives an overview of the project’s current system design as well as of the implementations of the key HDL entities supporting the software parts of the communication protocol. Furthermore, an approach for the dynamic reconfiguration of the devices is described, which provides several topology setups using a single PCB design.
This paper analyzes the applicability of existing communication technology on the Smart Grid. In particular it evaluates how networks, e.g. Peer-to-Peer (P2P) and decentralized Virtual Private Network (VPN) can help set up an agent-based system. It is expected that applications on Smart Grid devices will become more powerful and be able to operate without a central control instance. We analyze which requirements agents and Smart Grid devices place on communication systems and validate promising approaches. The main focus is to create a logical overlay network that provides direct communication between network nodes. We provide a comparison of different approaches of P2P networks and mesh-VPNs. Finally the advantages of mesh-VPN for agent-based systems are worked out.
Experiences with a telecare platform integration of ZigBee sensors into a middleware platform
(2012)
Die hohen Anforderungen vor allem an Drehmoment übertragende und mehrfachgekerbte Profilwellen im konstruktiven Umfeld moderner Maschinen zwingen uns, der Frage der Kerbwirkungen sowie Maßnahmen zu deren Milderung erhöhte Aufmerksamkeit zu widmen. Während die Kerbwirkung der geometrischen Einzelkerben bereits recht eingehend erforscht ist, liegen wesentlich komplexere Verhältnisse bei Mehrfachkerben vor, die durch die gegenseitige Beeinflussung mehrerer benachbarter Kerben entstehen. Der hier vorliegende Beitrag beschreibt erste Untersuchungsergebnisse mit der Finite-Elemente-Methode (FEM) zur gegenseitigen Wechselwirkung zweier Kerbformen "Sicherungsringnut und Zahnfußrundung" bei Zahnwellen mit Evolventenflanken nach DIN 5480. Diese Kerbkombination tritt in der Praxis häufig auf. Entsprechende Formzahldiagramme und Gestaltungshinweise werden angegeben und Näherungsformeln für die genauere Formzahlbestimmung je nach Belastungsart aufgestellt.
Capture threshold (CT) for transesophageal left atrial (LA) pacing (TLAP) and transesophageal left ventricular (LV) pacing (TLVP) with conventional cylindrical electrodes (CE) are higher than TLAP feeling threshold (FT). Purpose of the study was to evaluate focused TLAP CT and FT for supraventricular tachycardia (SVT) initiation and focused TLVP CT for cardiac resynchronisation therapy (CRT) simulation.
Methods: SVT initiation in patients (P) with palpitations (n=49, age 47 ± 17 years) was analysed during spontaneous rhythm and during focused bipolar TLAP with atrial constant current stimulus output, distal CE and three or seven 6 mm hemispherical electrodes (HE) (TO, Osypka AG, Rheinfelden, Germany). CRT simulation in heart failure P (n=75, age 62 ± 11 years) was evaluated by focused bipolar TLAP and/or TLVP with ventricular constant voltage stimulus output and different pacing mode.
Results: Focused electrical pacing field between CE and HE (n=28) allowed low threshold TLAP with 8.0 ± 2.6 mA CT at 9.9 ms stimulus duration (SD) which was lower than 9.2 ± 4.5 mA FT at 9.9 ms SD. Focused electrical pacing field between HE and HE (n=21) allowed low threshold TLAP with 8.1 ± 2.2 mA CT at 9.9 ms SD which was lower than 9.8 ± 5.0 mA FT at 9.9 ms SD. SVT initiation by programmed AAI TLAP was possible in 23 P and not possible in 26 P. CRT simulation was evaluated with TLAP and TLVP with VAT, D00 and V00 pacing mode and 95.5 ± 10.9 V TLVP CT at 4.0 ms SD.
Conclusions: Programmed focused AAI TLAP allowed initiation of SVT with very low CT and high FT and focused electrical pacing field between CE-HE and HE-HE.CRT simulation with focused TLAP and/or TLVP with VAT, D00 and V00 pacing mode may be a useful technique to detect responders to CRT.
Responder-rate in cardiac resynchronization therapy (CRT) of patients in sinus rhythm (SR) or atrial fibrillation (AF) mainly depends on accurat selection, optimal position of the left ventricular electrode and individualization of hemodynamical parameters of the implanted biventricular pacing system during follow-up. High resolution esophageal left heart electrocardiography offers a quick and semi-invasive approach to the electrical activity of left atrium and left ventricle. It was used in 62 heart failure patients in sinus rhythm and 11 in atrial fibrillation after implantation of CRT systems to compare the semi-invasive interventricular conduction delay (IVCDE) with QRS width. In all of the patients, guideline decision for CRT was linked with IVCDE of about 40ms and up. From logical point of view, IVCDE provides the minimal target interval for the left ventricular electrode placement in order to exclude non-responders. Esophageal measurement of interatrial conduction intervals in VDD and DDD pacing was utilized to individualize the AV delay and to exclude adverse hemodynamic effects.
Remote measurement of the physiology, so-called biotelemetry, is a key technology in the modern veterinary medicine. The usage of wireless implants has less impact on the behavior of animals than manual measurement methods and cause less disturbance than wired devices. But, common biotelemetry still uses proprietary communication and power concepts focused on small systems with one animal. Therefore, the University of Applied Sciences Offenburg is developing a low-cost RFID system called muTrans1, which is able to measure ECG, pressure, temperature, oxygen saturation and activity. The muTrans uses an own RFID sensor transponder and standardized commercial components and combines them to a scalable RFID system able to build-up RFID sensor networks with a nearly unlimited size.
Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy in approximately two-thirds of symptomatic heart failure (HF) patients (P) with left bundle branch block (LBBB). The aim of this study was to evaluate left atrial (LA) conduction delay (LACD) and left ventricular (LV) conduction delay (LVCD) using pre-implantational transesophageal electrocardiography (ECG) in sinus rhythm (SR) CRT responder (R) and non-responder (NR).
Methods: SR HF P (n=52, age 63.6±10.4 years; 6 females, 46 males) with New York Heart Association (NYHA) class 3.0±0.2, 24.4±7.1 % LV ejection fraction and 171.2±37.6 ms QRS duration (QRSD) were measured by bipolar filtered transesophageal LA and LV ECG recording with hemispherical electrodes (HE) TO catheter (Osypka AG, Rheinfelden, Germany). LACD was measured between onset of P-wave in the surface ECG and onset of LA deflection in the LA ECG. LVCD was measured between onset of QRS in the surface ECG and onset of LV deflection in the LV ECG.
Results: There were 78.8 % SR CRT R (n=41) with 171.2±36.9 ms QRSD, 73.3±25.7 ms LACD, 80.0±24.0 ms LVCD and 2.3±0.5 QRSD-LVCD-ratio. SR CRT R QRSD correlated with LACD (r=0.688, P<0.001) and LVCD (r=0.699, P<0.001). There were 21.2 % SR CRT NR (n=11) with 153.4±22.4 ms QRSD (P=0.133), 69.8±24.8 ms LACD (n=6, P=0.767), 54.2±31.0 ms LVCD (P<0.0046) and 3.9±2.5 QRSD-LVCD-ratio (P<0.001). SR CRT NR QRSD not corre-lated with IACD (r=-0.218, P=0.678) and IVCD (r=0.042, P=0.903). During a 22.8±21.3 month CRT follow-up, the CRT R NYHA class improved from 3.1±0.3 to 1.9±0.3 (P<0.001). In CRT NR, NYHA class not improved (2.9±0.4 to 2.9±0.2, P=1) during 11.2±9.8 months BV pacing.
Conclusions: Transesophageal LA and LV ECG with HE can be utilized to analyse LACD and LVCD in HF P. Pre-implantational LVCD and QRSD-LVCD-ratio may be additional useful parameters to improve P selection for SR CRT.
Machine-to-machine communication is continuously extending to new application fields. Especially smart metering has the potential to become the first really large-scale M2M application. Although in the future distributed meter devices will be mainly connected via dedicated primary communication protocols, like ZigBee, Wireless
M-Bus or alike, a major percentage of all meters will be connected via point to point communication using GPRS or UMTS platforms. Thus, such meter devices have to be extremely cost and energy efficient, especially if the devices are battery based and powered several years by a single battery. This paper presents the development of an automated measurement unit for power and time, thus energy characteristics can be recorded. The measurement unit includes a hardware platform for the device
under test (DUT) and a database based software environment for a smooth execution and analysis of the measurements.
In the field of smart metering it can be observed that standardized protocol, like Wireless M-Bus or ZigBee, enjoy a rapidly increasing popularity. For the protocol implementations, however, up to now, mostly legacy engineering processes and technologies are used, and modern approaches such as model driven design processes or open software platform are disregarded. Therefore, within the WiMBex project, it shall be demonstrated that it is possible to develop a commercial class Wireless M-Bus implementation following state-of-the art design process and using TinyOS as an open source platform. This contribution describes the overall approach of the project, as well as the state and the first experiences of the current work in progress.
MPC-Workshop Februar 2012
(2012)
MPC-Workshop Juli 2012
(2012)
New frontiers of supraventricular tachycardia and atrial flutter evaluation and catheter ablation
(2012)
Radiofrequency catheter ablation (RFCA) has revolutionized treatment for tachyarrhythmias and has become first-line therapy for some tachycardias. Although developed in the 1980s and widely applied in the 1990s, the technique is still in development. Transesophageal atrial pacing (TAP) can used for initiation and termination of supraventricular tachycardia (SVT).
Methods: The paroxysmal SVT include a wide spectrum of disorders including, in descending order of frequency, atrial flutter, atrioventricular (AV) nodal reentry, Wolff-Parkinson-White syndrome, and atrial tachycardia. While not life-threatening in most cases, they may cause important symptoms, such as palpitations, chest discomfort, breathlessness, anxiety, and syncope, which significantly impair quality of life. Medical therapy has variable efficacy, and most patients are not rendered free of symptoms. Research over the past several decades has revealed fundamental mechanisms involved in the initiation and maintenance of all of these arrhythmias. Knowledge of mechanisms has in turn led to highly effective surgical and catheter-based treatments. The supraventricular arrhythmias and their treatment are described in this report. SVT initiation was analysed with programmed TAP in 49 patients with palpitations (age 47 ± 17 years, 24 females, 25 males).
Results: In comparison to antiarrhythmic drug therapy the radiofrequency catheter ablation in patients suffering from atrial flutter, atrioventricular nodal reentry, atrioventricular reentry and atrial tachycardia is the better choice in most cases. TAP SVT initiation was possible in 23 patients before RFCA. Atrial cycle length of SVT was 320 ± 59 ms. We initiated AV nodal reentrant tachycardia (AVNRT, n=15), atrial tachycardia (AT, n=6) and AV reentrant tachycardia with Kent pathway conduction (AVRT, n=2) before RFCA.
Conclusions: Radiofrequency catheter ablation is a successful and safe method to cure most patients with paroxysmal supraventricular tachycardias. TAP allowed initiation and termination of SVT especially in outpatients.
About 20% of those heart failure patients receiving cardiac resynchronization therapy (CRT) are in atrial fibrillation (AF). Current guidelines apply for patients in sinus rhythm only. Recent studies have shown again, that successful resynchronization is closely linked to a pre-existent ventricular desynchronization. In those studies, the interventricular conduction delay (IVCD) was determined prior to device implantation by ultrasound in patients with sinus rhythm (SR)only. In patients with AF this method ́s use is limited.
To implement left-heart electrogram (LHE) into standard programmers and to simplify IVCD measurement in heart failure patients with AF, LHE was recorded in 11 AF patients with heart failure by Biotronik ICS3000 programmer via a15Hz Butterworth high-pass filter. Therefore, TOslim esophageal electrode (Dr. Osypka GmbH, Rheinfelden, Germany) was perorally applied and fixed in position of maximal left ventricular defection. IVCD was measured between onset of QRS in surface ECG and left ventricular defection (LV) in LHE. In addition, intra-left ventricular conduction delay (ILVCD) was measured as duration of LV in LHE.
In all of the 11 AF patients, desynchronization was quantifiable by LHE. Mean QRS of 162 ± 27ms (120-206ms) was linked with IVCD of 62ms ± 27ms (37-98ms) and ILVCD of 110 ± 20ms (80-144ms), at mean. Correlation between IVCD and QRS was 0.39 (n. s.) with IVCD/QRS ratio of 0.38 ± 0.11 (0.22-0.81).
A 15Hz high-pass filtered LHE feature of the Biotronik ICS3000 programmer is feasible to quantify ventricular dyssynchrony in heart failure patients with AF in order to clearly indicate implantation of CRT systems. As relations between QRS duration, IVCD and ILVCD considerably differ interindividually, the predictive values of IVCD, ILVCD and IVCD/QRS ratio for individual CRT response or non-response shall be identified in follow-up studies.
Cardiac resynchronization therapy (CRT) with biventricular pacing is an established therapy for heart failure (HF) patients (P) with ventricular desynchronization and reduced left ventricular (LV) ejection fraction. The aim of this study was to evaluate electrical right atrial (RA), left atrial (LA), right ventricular (RV) and LV conduction delay with novel telemetric signal averaging electrocardiography (SAECG) in implantable cardioverter defibrillator (ICD) P to better select P for CRT and to improve hemodynamics in cardiac pacing.
Methods: ICD-P (n=8, age 70.8 ± 9.0 years; 2 females, 6 males) with VVI-ICD (n=4), DDD-ICD (n=3) and CRT-ICD (n=1) (Medtronic, Inc., Minneapolis, MN, USA) were analysed with telemetric ECG recording by Medronic programmer 2090, ECG cable 2090AB, PCSU1000 oscilloscope with Pc-Lab2000 software (Velleman®) and novel National Intruments LabView SAECG software.
Results: Electrical RA conduction delay (RACD) was measured between onset and offset of RA deflection in the RAECG. Interatrial conduction delay (IACD) was measured between onset of RA deflection and onset of far-field LA deflection in the RAECG. Interventricular conduction delay (IVCD) was measured between onset of RV deflection in the RVECG and onset of LV deflection in the LVECG. Telemetric SAECG recording was possible in all ICD-P with a mean of 11.7 ± 4.4 SAECG heart beats, 97.6 ± 33.7 ms QRS duration, 81.5 ± 44.6 ms RACD, 62.8 ± 28.4 ms RV conduction delay, 143.7 ± 71.4 ms right cardiac AV delay, 41.5 ms LA conduction delay, 101.6 ms LV conduction delay, 176.8 ms left cardiac AV delay, 53.6 ms IACD and 93 ms IVCD.
Conclusions: Determination of RA, LA, RV and LV conduction delay, IACD, IVCD, right and left cardiac AV delay by telemetric SAECG recording using LabView SAECG technique may be useful parameters of atrial and ventricular desynchronization to improve P selection for CRT and hemodynamics in cardiac pacing.
During the last ten years the development of wireless sensing applications has become more and more attractive. A major reason for this trend is the large quantity of available wireless technologies. The progressing demand on wireless technologies is mainly driven through development from the industrial wireless sensors market. Especially requirements like low energy consumption, a resource saving simple protocol stack and short timing delays between different states of the wireless transceivers are very important for wireless sensors. Bluetooth Low Energy (BLE) is a rather new wireless standard in addition to the traditional Bluetooth standard (Basis rate and enhanced data rate, BR/EDR) [1]. The BLE will completely fulfill these fundamental requirements. First BLE transceiver chips and modules are available and have been tested and implemented in products. In this paper the performance analysis results of a BLE sensor system which is based on the TI transceiver CC2540F [5] will be presented. The results can be taken for further important investigations like lifetime calculations or BLE simulation models.