Synthesis and crystal structure of a novel copper-based MOF material are presented. The tetragonal crystal structure of [ ∞ 3 ( Cu 4 ( μ 4 -O ) ( μ 2 -OH ) 2 ( Me 2 trz p ba ) 4 ] possesses a calculated solvent-accessible pore volume of 57%. Besides the preparation of single crystals, synthesis routes to microcrystalline materials are reported. While PXRD measurements ensure the phase purity of the as-synthesized material, TD-PXRD measurements and coupled DTA–TG–MS analysis confirm the stability of the network up to 230 °C. The pore volume of the microcrystalline material determined by nitrogen adsorption at 77 K depends on the synthetic conditions applied. After synthesis in DMF/H2O/MeOH the pores are blocked for nitrogen, whereas they are accessible for nitrogen after synthesis in H2O/EtOH and subsequent MeOH Soxhleth extraction. The corresponding experimental pore volume was determined by nitrogen adsorption to be V Pore = 0.58 cm 3 g - 1 . In order to characterize the new material and to show its adsorption potential, comprehensive adsorption studies with different adsorptives such as nitrogen, argon, carbon dioxide, methanol and methane at different temperatures were carried out. Unusual adsorption–desorption isotherms with one or two hysteresis loops are found – a remarkable feature of the new flexible MOF material.
High pressure adsorption phenomena are discussed for different gases on HKUST-1 (Cu3(BTC)2, commercially available product BasoliteTM C300). Sorption isotherms for hydrogen, nitrogen, methane and carbon dioxide on HKUST-1 were measured in the temperature range of 273–343 K and at pressures up to 50 MPa. The calculated surface excess adsorption capacities for all four adsorptive are one of the highest reported in the literature for HKUST-1 samples. All surface excess data were further calculated from the experimental data by using the helium buoyancy correction. A detailed description was given.
Also a procedure to calculate the absolute amount adsorbed from the surface excess amount by using two different models is shown. Using one model, the density and the volume of the adsorbed phase can be calculated. The density of the adsorbed phase ρads corresponds to the liquid density of the adsorptive at its boiling point ρliq,BP. In case of hydrogen no excess maximum was found up to 50 MPa, so that one model could not be applied. Finally, the isosteric heat of adsorption for each gas was calculated by using the Clausius–Clapeyron equation.
The series of conferences on Environmental Best Practices (EBP) was inaugurated at the University of Warmia and Mazury in Olsztyn, Poland in 2006 and continued at the Jagiellonian University in Kraków, Poland in 2009. This year the University of Applied Sciences Offenburg produly hosted the third event (EPB3).
This paper describes the magmaOffenburg 3D simulation team trying to qualify for RoboCup 2011. While last year’s TDP focused on the tool set created for 3D simulation in this year we describe the further improvement in this tools as well as some new features we implemented focusing on heterogeneous robot models which seem to be used in RoboCup 2012.
An additional tool was written to simply generate situation-dependent strategies. Furthermore some tools, described last year, are now integrated in one single GUI to easy things up.
Introduction: Patient selection for cardiac resynchronization therapy (CRT) requires quantification of left ventricular conduction delay (LVCD). After implantation of biventricular pacing systems, individual AV delay (AVD) programming is essential to ensure hemodynamic response. To exclude adverse effects, AVD should exceed individual implant-related interatrial conduction times (IACT). As result of a pilot study, we proposed the development of a programmer-based transoesophageal left heart electrogram (LHE) recording to simplify both, LVCD and IACT measurement. This feature was implemented into the Biotronik ICS3000 programmer simultaneously with 3-channel surface ECG.
Methods: A 5F oesophageal electrode was perorally applied in 44 heart failure CRT-D patients (34m, 10f, 65±8 yrs., QRS=162±21ms). In position of maximum left ventricular deflection, oesophageal LVCD was measured between onsets of QRS in surface ECG and oesophageal left ventricular deflection. Then, in position of maximum left atrial deflection (LA), IACT in VDD operation (As-LA) was calculated by difference between programmed AV delay and the measured interval from onset of left atrial deflection to ventricular stimulus in the oesophageal electrogram. IACT in DDD operation (Ap-LA) was measured between atrial stimulus and LA..
Results: LVCD of the CRT patients was characterized by a minimum of 47ms with mean of 69±23ms. As-LA and Ap-LA were found to be 41±23ms and 125±25ms, resp., at mean. In 7 patients (15,9%), IACT measurement in DDD operation uncovered adverse AVD if left in factory settings. In this cases, Ap-LA exceeded the factory AVD. In 6 patients (13,6%), IACT in VDD operation was less than or equal 10ms indicating the need for short AVD.
Conclusion: Response to CRT requires distinct LVCD and AVD optimization. The ICS3000 oesophageal LHE feature can be utilized to measure LVCD in order to justify selection for CRT. IACT measurement simplifies AV delay optimization in patients with CRT systems irrespective of their make and model.
Introduction: To simplify AV delay (AVD) optimization in cardiac resynchronization therapy (CRT), we reported that the hemodynamically optimal AVD for VDD and DDD mode CRT pacing can be approximated by individually measuring implant-related interatrial conduction intervals (IACT) in oesophageal electrogram (LAE) and adding about 50ms. The programmer-based St Jude QuickOpt algorithm is utilizing this finding. By automatically measuring IACT in VDD operation, it predicts the sensed AVD by adding either 30ms or 60ms. Paced AVD is strictly 50ms longer than sensed AVD. As consequence of those variations, several studies identified distinct inaccuracies of QuickOpt. Therefore, we aimed to seek for better approaches to automate AVD optimization.
Methods: In a study of 35 heart failure patients (27m, 8f, age: 67±8y) with Insync III Marquis CRT-D systems we recorded telemetric electrograms between left ventricular electrode and superior vena cava shock coil (LVtip/SVC = LVCE) simultaneously with LAE. By LVCE we measured intervals As-Pe in VDD and Ap-Pe in DDD operation between right atrial sense-event (As) or atrial stimulus (Ap), resp., and end of the atrial activity (Pe). As-Pe and Ap-Pe were compared with As-LA an Ap-LA in LAE, respectively.
Results: End of the left atrial activity in LVCE could clearly be recognized in 35/35 patients in VDD and 29/35 patients in DDD operation. We found mean intervals As-LA of 40.2±24.5ms and Ap-LA of 124.3±20.6ms. As-Pe was 94.8±24.1ms and Ap-Pe was 181.1±17.8ms. Analyzing the sums of As-LA + 50ms with duration of As-Pe and Ap-LA + 50ms with duration of Ap-Pe, the differences were 4.7±9.2ms and 4.2±8.6ms, resp., only. Thus, hemodynamically optimal timing of the ventricular stimulus can be triggered by automatically detecting Pe in LVCE.
Conclusion: Based on minimal deviations between LAE and LVCE approach, we proposed companies to utilize the LVCE in order to automate individual AVD optimization in CRT pacing.
In this paper we suggest to combine the areas of media streaming services, mobile devices, and manufacturing processes to support monitoring, controlling and supervising production processes in order to achieve high levels of efficiency and environmentally friendly production. It contains a comprehensive and detailed explanation of the proposed E-Learning streaming framework, especially the adaption of streaming services to mobile environments. The key components of our approach are 1) an XML-based streaming service specification language, 2) adaption of multimedia E-Learning services to mobile environments, and 3) a media delivery platform for searching, registration, and creation of streaming services for mobile devices.
In-vivo and in-vitro comparison of implant-based CRT optimization - What provide new algorithms?
(2011)
Introduction: In cardiac resynchronization therapy (CRT), individual AV delay (AVD) optimization can effectively increase hemodynamics and reduce non-responder rate. Accurate, automatic and easily comprehensible algorithms for the follow-up are desirable. QuickOpt is the first attempt of a semi-automatic intracardiac electrogram (IEGM) based AVD algorithm. We aimed to compare its accuracy and usefulness by in-vitro and in-vivo studies.
Methods: Using the programmable ARSI-4 four-chamber heart rhythm and IEGM simulator (HKP, Germany), the QuickOpt feature of an Epic HF system (St. Jude, USA) was tested in-vitro by simulated atrial IEGM amplitudes between 0.3 and 3.5mV during both, manual and automatic atrial sensing between 0.2 and 1.0mV. Subsequently, in 21 heart failure patients with implanted biventricular defibrillators, QuickOpt was performed in-vivo. Results of the algorithm for VDD and DDD stimulation were compared with echo AV delay optimization.
Results: In-vitro simulations demonstrated a QuickOpt measuring accuracy of ± 8ms. Depending on atrial IEGM amplitude, the algorithm proposed optimal AVD between 90 and 150ms for VDD and between 140 and 200ms for DDD operation, respectively. In-vivo, QuickOpt difference between individual AVD in DDD and VDD mode was either 50ms (20pts) or 40ms (1pt). QuickOpt and echo AVD differed by 41 ± 25ms (7 – 90ms) in VDD and by 18 ± 24ms (17-50ms) in DDD operation. Individual echo AVD difference between both modes was 73 ± 20ms (30-100ms).
Conclusion: The study demonstrates the value of in-vitro studies. It predicted QuickOpt deficiencies regarding IEGM amplitude dependent AVD proposals constrained to fixed individual differences between DDD and VDD mode. Consequently, in-vivo, the algorithm provided AVD of predominantly longer duration than echo in both modes. Accepting echo individualization as gold standard, QuickOpt should not be used alone to optimize AVD in CRT patients.
Digital libraries are providing an increasing amount of data, which is normally structured in a classical way by documents and described by metadata as keywords. The data, even in scientific systems such as digital libraries and virtual research environments, will contain a great amount of noise or information unnecessary for our personal interests. Although there has been a lot of progress in the field of information retrieval, search techniques and other content finding methods, there is still much to be done in the field of information retrieval based on user behavior. This paper presents an approach deployed in the Humboldt Digital Library (HDL) to facilitate the retrieval of relevant information to the users of the system, making recommendations of paragraphs based on their profile and the behavior of other users who share similar profiles. The Humboldt digital library represents an innovative system of open access to the legacy of Alexander von Humboldt in a digital form on the Internet (www.avhumboldt.net). It contributes to the key question, how to present interconnected data in a proper form using information technologies.
Existing approaches solving multi-vehicle pickup and delivery problems with soft time windows typically use common benchmark sets to verify their performance. However, there is a gap from these benchmark sets to real world problems with respect to instance size and problem complexity. In this paper we show that a combination of existing approaches together with improved heuristics is able to deal with the instance sizes and complexity of real world problems. The cost savings potential of the heuristics is compared to human dispatching plans generated from the data of a European carrier.
A simple model is introduced that describes the interaction of surface acoustic waves (SAWs) with a 2D periodic array of objects on the surface that give rise to internal resonances. Such objects may be high-aspect ratio structures like micro-pillars fabricated of a material different from that of the substrate. The model allows for an approximate determination of the band structure for the acoustic modes in such systems. Results are presented for the dependence on structural parameters of a total bandgap in the non-radiative regime of a semi-infinite substrate, and it is shown how the frequency and radiation damping of vibrational modes can be determined that are associated with defects in the periodic 2D array.
Significance of new electrocardiographic parameters to improve cardiac resynchronization therapy
(2011)
Introduction: Oesophageal left heart electrogram (LHE) is a valuable tool providing electrocardiographic parameters for cardiac resynchronization therapy (CRT). It can be utilized to measure left ventricular (LVCD) and intra-leftventricular conduction delays (ILVCD) in heart failure patients to justify implantation of CRT systems. In the follow-up, LHE enables measurement of implant-related interatrial conduction times (IACT) which are the key intervals defining the hemodynamically optimal AV delay (AVD).
Methods: By TOSlim oesophageal electrode and Rostockfilter (Osypka AG, Rheinfelden, Germany), LHE was recorded in 39 heart failure patients (10f, 29m, 65±8yrs., QRS=163±21ms) after implantation of CRT systems according to guidelines. In position of maximal left ventricular deflection, LVCD and ILVCD were measured and compared with QRS width. In position of maximal left atrial deflection (LA), IACT was determined in VDD and DDD operation as interval As-LA and Ap-LA between atrial sense event (As) or stimulus (Ap), resp., and onset of LA. AVD was individualized using SAV =As-LA + 50ms for VDD and PAV=Ap-LA + 50ms for DDD operation.
Results: The CRT patients were characterized by minimal transoesophageal LVCD of 40ms but 73±20ms, at mean, ILVCD of 90±24ms and QRS/LVCD ratio of 2.4±0.6. The measured As-LA of 39±24ms and Ap-LA of 124±26ms resulted into SAV of 89±24ms and PAV of 174±26ms. In case of empirical AVD programming using 120ms for SAV and 180ms for PAV, the LHE revealed inverse sequences of LA and Vp in 4 patients (10%) during VDD and 13 patients (33%) in DDD pacing. In these patients, Vp preceded LA as IACT exceeded the programmed AVD.
Conclusion: Guideline indication of CRT systems is associated with LVCD of 40ms or more. Therefore, individual LVCD offers the minimal target interval that should be reached during left ventricular electrode placement to increase responder rate. Postoperatively, AV delay optimization respecting implant-related IACTs excludes adverse hemodynamic effects.
Electrical velocimetry to optimize VV delay in biventricular VVIR and DDD pacing for heart failure
(2011)
Introduction: VV delay (VVD) is the only parameter to hemodynamically optimize cardiac resynchronization therapy (CRT) for patients with atrial fibrillation (AF). Electrical velocimetry (EV) has been established to monitor thoracic electrical conductivity and to calculate hemodynamic surrogate parameters. We compared the response of this method to hemodynamic parameter changes between CRT patients with sinus rhythm (SR) and patients with AF.
Methods: VVD was individualized in 17 CRT patients in SR (12m, 5f, 67.0±7.2yrs.) after echo AV delay optimization and in 11 CRT patients in AF (10m, 1f, 69.8±9.6yrs.) using the Aesculon Cardiovascular Monitor (Osypka Medical, Berlin, Germany). Serial 30s EV recordings were accomplished, decreasing the VVD stepwise by 10ms from +60ms to -60ms between right and left ventricular stimulus. Optimal VVD was determined by the maximum of at least two of the three averaged parameters stroke volume (SV), cardiac output (CO) and cardiac index (CI). The response of SV, CO and CI was tested comparing their values in optimal VVD and suboptimal VVD. Suboptimal VVD was defined by optimal VVD±20ms.
Results: In all 28 patients in SR and AF, EV recordings resulted in optimal VVD. Between suboptimal and optimal mean VVD of 18.6±30.8ms between left and right ventricular stimulus, SV increased by 7.2±6.8%, CO by 7.8±7.2% and CI by 10.0±13.3% (all p<0.02). In the SR group with VVD of 18.8± 29.6ms, SV increased by 4.6±2.9%, CO by 5.0±2.9% and CI by 4.9±2.9% (all p<0.02). In the AF group with VVD of 18.2±4.0ms, SV increased by 10.4±8.9%, CO by 11.3±9.5% and CI by 16.4±18.2% (all p<0.02). Significant differences were not found between optimal VVD in SR and AF patients.
Conclusion: EV is a feasible serial method to individualize VVD in DDD and VVIR pacing for heart failure. Its response to hemodynamic changes demonstrates the value of EV for VVD fine-tuning.