Refine
Year of publication
Document Type
- Article (unreviewed) (19) (remove)
Language
- English (19) (remove)
Has Fulltext
- no (19)
Is part of the Bibliography
- yes (19) (remove)
Keywords
- Dünnschichtchromatographie (3)
- Vergleich (2)
- Aufzeichnung (1)
- Benzodiazepine (1)
- Bioelement (1)
- Electrolyte-gated transistors (1)
- Erfrischungsgetränk (1)
- FT-Raman spectroscopy (1)
- Feldeffekt (1)
- Flüssigkeit (1)
Institute
Open Access
- Closed Access (19) (remove)
Our media-artistic performances and installations, INTERCORPOREAL SPLITS (2010–2013), BUZZ (2014–2015), W ASTELAND (2015–2016), as well as our new collaboration with Bruno Latour , DE\GLOBALIZE (2018–2020), are not just about polyphony. Here, however, we rediscover them under this heading, thus giving them a new twist, while mapping out issues, mechanisms and functional modes of the polyphonic.
Micro-cracks give rise to non-analytic behavior of the stress-strain relation. For the case of a homogeneous spatial distribution of aligned flat micro-cracks, the influence of this property of the stress-strain relation on harmonic generation is analyzed for Rayleigh waves and for acoustic wedge waves with the help of a simple micromechanical model adopted from the literature. For the efficiencies of harmonic generation of these guided waves, explicit expressions are derived in terms of the corresponding linear wave fields. The initial growth rates of the second harmonic, i.e., the acoustic nonlinearity parameter, has been evaluated numerically for steel as matrix material. The growth rate of the second harmonic of Rayleigh waves has also been determined for microcrack distributions with random orientation, using a model expression for the strain energy in terms of strain invariants known in a geophysical context.
Electrolyte-Gated Field-Effect Transistors Based on Oxide Semiconductors: Fabrication and Modeling
(2017)
Phenolic compounds, such as flavonoids and phenolic acids, are very important substances that occur in various medicinal plants. They show different pharmacological activities which might be useful in the therapy of many diseases. Phenolic compounds have achieved an increasing interest over the last years because these compounds are easily oxidized and, thus, act as strong antioxidants. We present the chemiluminescence of different phenolic compounds measured directly on high-performance thin-layer chromatography LiChrospher® plates using the oxalic acid derivative bis(2,4,6-trichlorophenyl) oxalate (TCPO) in conjunction with H2O2. Our results indicate that chemiluminescence intensity increases with an ascending number of phenolic groups in the molecule. The method can be used to detect phenolic compounds in beverages like coffee, tea, and wine.
We present a videodensitometric quantification method for methadone in syrup, separated by thin-layer chromatography (TLC). The quantification is based on a derivation reaction with Dragendorf reagent. Measurements were carried out using a 16-bit flatbed scanner. The range of linearity covers two magnitudes of power using the Kubelka-Munk expression for data transformation. The separation method is inexpensive, fast, and reliable.
The Raman spectra from the chemical compounds toluene and cyclohexane obtained using a Fourier Transform (FT)-Raman spectrometer prototype have been contrasted with the Raman spectra of these same materials collected with two different commercial FT-Raman devices. The FT-Raman spectrometer consist of a Michelson interferometer, a self-designed photon counter and a reference photo-detector. The evaluation methodology of the spectral information, contrary to the commercial devices that commonly use the zero-crossing method, is carried out by re-sampling the Raman scattering and by accurately extracting the optical path information of the Michelson interferometer. The FTRaman arrangement has been built using conventional parts without disregarding the spectral frequency precision that usually such a FTRaman instruments deliver. No additional complex hardware components or costly software modules have been included in this FT-Raman device. The main Raman lines from the spectra obtained with the three FT-Raman devices have been compared with the Raman lines from the standard Raman spectra of these two materials. The values obtained using the FT-Raman spectrometer prototype have shown a frequency accuracy comparable to that obtained with the commercial devices without facing the need for a large investment. Although the proposed FT-Raman prototype cannot be directly compared to the last generation of FT-Raman spectrometers from the commercial manufacturers, such a device could give an opportunity to users that require high frequency precision in their spectral analysis and are provided with rather scarce resources.
Mice and rats make up 95% of all animals used in medical research and drug discovery and development. Monitoring of physiological functions such as ECG, blood pressure, and body temperature over the entire period of an experiment is often required. Restraining of the animals in order to obtain this data can cause great inconvenience. The use of telemetric systems solves this problem and provides more reliable results. However, these devices are mostly equipped with batteries, which limit the time of operation or they use passive power supplies, which affects the operating range. The semi-passive telemetric implant being presented is based on RFID technology and overcomes these obstacles. The device is inductively powered using the magnetic field of a common RFID reader device underneath the cage, but is also able to operate for several hours autonomously. Being independent from the battery capacity, it is possible to use the implant over a long period of time or to re-use the device several times in different animals, thus avoiding the disadvantages of existing systems and reducing the costs of purchase and refurbishment.
Pressure dynamics in metal-oxygen (metal-air) batteries: a case study on sodium superoxide cells
(2014)
Electrochemical reactions in metal–oxygen batteries come along with the consumption or release of gaseous oxygen. We present a novel methodology for investigating electrode reactions and transport phenomena in metal–oxygen batteries by measuring the pressure dynamics in an enclosed gas reservoir above the oxygen electrode. The methodology is exemplified by a room-temperature sodium–oxygen battery forming sodium superoxide (NaO2) in an electrolyte of diethylene glycol dimethyl ether (diglyme) and sodium trifluoromethanesulfonate (NaOSO2CF3, NaOTf). The experiments are supported by microkinetic simulations with a one-dimensional multiphysics continuum model. During galvanostatic cycling over 30 cycles, a constant oxygen consumption/release rate is observed upon discharge/charge. The number of transferred electrons per oxygen molecule is calculated to 1.01 ± 0.02 and 1.03 ± 0.02 for discharge and charge, respectively, confirming the nature of the oxygen reaction product as superoxide O2–. The same ratio is observed in cyclic voltammetry experiments with low scan rate (<1 mV/s). However, at higher scan rates, the ratio increases as a result of oxygen transport limitations in the electrolyte. We introduce electrochemical pressure impedance spectroscopy (EPIS) for simultaneously analyzing current, voltage, and pressure of electrochemical cells. Pressure recording significantly increases the sensitivity of impedance toward oxygen transport properties of the porous electrode systems. In addition, we report experimental data on the diffusion coefficient and solubility of oxygen in electrolyte solutions as important parameters for the microkinetic models.
Rotation of an elastic medium gives rise to a shift of frequency of its acoustic modes, i.e., the time-period vibrations that exist in it. This frequency shift is investigated by applying perturbation theory in the regime of small ratios of the rotation velocity and the frequency of the acoustic mode. In an expansion of the relative frequency shift in powers of this ratio, upper bounds are derived for the first-order and the second-order terms. The derivation of the theoretical upper bounds of the first-order term is presented for linear vibration modes as well as for stable nonlinear vibrations with periodic time dependence that can be represented by a Fourier series.
An interlaboratory comparison was carried out to evaluate the effectiveness of a method based on HPTLC in which reagent-free derivatization is followed by UV/fluorescence detection. The method was tested for the determination of sucralose (C12H19C13O8; (2R,3R,4R,5S,6R)-2-[(2R,3S,4S,5S)-2,5-bis(chloromethyl)-3,4-dihydroxyoxolan-2-yl]oxy-5-chloro-6-hydroxymethyl)oxane-3, 4-diol; CAS Registry No. 56038-13-2) in carbonated and still beverages at the proposed European regulatory limits. For still beverages, a portion of the sample was diluted with methanol-water. For carbonated beverages, a portion of the sample was degassed in an ultrasonic bath before dilution. Turbid beverages were filtered after dilution through an HPLC syringe filter. The separation of sucralose was performed by direct application on amino-bonded (NH2) silica gel HPTLC plates (no cleanup needed) with the mobile phase acetonitrile-water. Sucralose was determined after reagent-free derivatization at 190 degrees C; it was quantified by measurements of both UV absorption and fluorescence. The samples, both spiked and containing sucralose, were sent to 14 laboratories in five different countries. Test portions of a sample found to contain no sucralose were spiked at levels of 30.5, 100.7, and 299 mg/L. Recoveries ranged from 104.3 to 124.6% and averaged 112% for determination by UV detection; recoveries ranged from 98.4 to 101.3% and averaged 99.9% for determination by fluorescence detection. On the basis of the results for spiked samples (blind duplicates at three levels), as well as sucralose-containing samples (blind duplicates at three levels and one split level), the values for the RSDr ranged from 10.3 to 31.4% for determinations by UV detection and from 8.9 to 15.9% for determinations by fluorescence detection. The values for the RSDR values ranged from 13.5 to 31.4% for determinations by UV detection and from 8.9 to 20.7% for determinations by fluorescence detection.
This paper focuses on the effects of differential mode delay (DMD) on the bandwidth of multimode optical fibres. First an analytical solution for the computation of the differential mode time delay is presented. The electrical field of each mode is calculated by the numerical solution of the Helmholtz equation. Based on this solution the modal power distribution as well as the fibre's impulse response under different launching conditions can be obtained.
Next, the refractive-index profile of two fibres is modelled on the basis of DMD measurements. It is shown that these measurements provide enough information to predict the fibre's propagation characteristics under different launch conditions (excitation conditions).
In thin-layer chromatography the development step distributes the sample throughout the layer, a process which strongly affects the reflection signals. The essential requirement for quantitative thinlayer chromatography is not a constant sample concentration but constant sample distribution in each sample spot. This makes evaporation of the mobile phase extremely important, because all tracks of a TLC plate must be dried uniformly. This paper shows that quantitative TLC is possible even if the concentration of the sample is not constant throughout the layer or if the distribution of the sample is not known. With uniform sample distribution, classical Kubelka-Munk theory is valid for isotropic scattering only. In the absence of this constraint classical Kubelka-Munk theory must be extended to situations where scattering is asymmetric. This can be achieved by modification of the original Kubelka-Munk equation. Extended theory is presented which is not only capable of describing asymmetrical scattering in TLC layers but also includes a formula for absorption and fluorescence in diode-array TLC. With this new theory all different formulas for diode-array thin-layer chromatographic evaluation are combined in one expression.
Diode-array planar chromatography is a versatile tool for identification of pharmaceutical substances In this paper thirty-three compounds with benzodiazepine properties were investigated and the separating conditions for silica gel HPTLC plates and three mobile phases were optimized. Diode-array HPTLC makes it possible to identify all the compounds with high certainty down to a level of 20 ng. An algorithm for spectral recognition which is combined with R F values from the three separation steps into one fit factor is presented. This set of data is unique for each of the compounds investigated and enables unequivocal identification. The method is rapid, inexpensive, and sensitive down to a level of 20 ng mL −1.
Specific prototypes of sedimentation field flow fractionation devices (SdFFF) have been developed with relative success for cell sorting. However, no data are available to compare these apparatus with commercial ones. In order to compare with other devices mainly used for non-biological species, biocompatible systems were used for standard particle (latex: 3–10 μm of different size dispersities) separation development. In order to enhance size dependent separations, channels of reduced thickness were used (80 and 100 μm) and channel/carrier-phase equilibration procedures were necessary. For sample injection, the use of inlet tubing linked to the FFF accumulation wall, common for cell sorting, can be extended to latex species when they are eluted in the Steric Hyperlayer elution mode. It avoids any primary relaxation steps (stop flow injection procedure) simplifying series of elution processing. Mixtures composed of four different monodispersed latex beads can be eluted in 6 min with 100 μm channel thickness.
The three wavelength extinction method (3-WEM) was applied for the on-line particle analysisof suspensions of monodisperse latex beads and polydisperse metal oxide particles of industrialinterest. Comparative measurements were performed by photon correlation spectroscopy (PCS). Thedata of latex particles obtained by 3-WEM and PCS are in good agreement with the manufacture’svalues. Also, the values of oxide particles measured by means of the two techniques are in reasonableagreement despite of the irregular particle shape.Discrepancies are observed by comparing the oxideparticle size results with those of scanning electron microscopy, which is due to the broad sampledistributions and shape irregularities.
In contrast to their traditional, non-interactive counterparts, interactive dynamic visualisations allow users to adapt their form and content to their individual cognitive skills and needs. Provided that the interactive features allow for intuitive use without increasing cognitive load, interactive videos should therefore lead to more efficient forms of learning. This notion was tested in an experimental study, where participants learned to tie four nautical knots of different complexity by watching either non-interactive or interactive videos. The results show that in the interactive condition, participants used the interactive features like stopping, replaying, reversing or changing speed to adapt the pace of the video demonstration. This led to an uneven distribution of their attention and cognitive resources across the videos, which was more pronounced for the difficult knots. Consequently users of non-interactive video presentations, needed substantially more time than users of the interactive videos to acquire the necessary skills for tying the knots.