Refine
Document Type
- Article (unreviewed) (17) (remove)
Has Fulltext
- no (17)
Is part of the Bibliography
- yes (17)
Keywords
- Archäologie (1)
- Aufzeichnung (1)
- Bioelement (1)
- Convolutional Neural Network (1)
- Desktop-Virtualisierung (1)
- Eisen (1)
- Electrolyte-gated transistors (1)
- FT-Raman spectroscopy (1)
- Feldeffekt (1)
- Fourier, Jean Baptiste Joseph (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (17) (remove)
Open Access
- Closed Access (17) (remove)
The Raman spectra from the chemical compounds toluene and cyclohexane obtained using a Fourier Transform (FT)-Raman spectrometer prototype have been contrasted with the Raman spectra of these same materials collected with two different commercial FT-Raman devices. The FT-Raman spectrometer consist of a Michelson interferometer, a self-designed photon counter and a reference photo-detector. The evaluation methodology of the spectral information, contrary to the commercial devices that commonly use the zero-crossing method, is carried out by re-sampling the Raman scattering and by accurately extracting the optical path information of the Michelson interferometer. The FTRaman arrangement has been built using conventional parts without disregarding the spectral frequency precision that usually such a FTRaman instruments deliver. No additional complex hardware components or costly software modules have been included in this FT-Raman device. The main Raman lines from the spectra obtained with the three FT-Raman devices have been compared with the Raman lines from the standard Raman spectra of these two materials. The values obtained using the FT-Raman spectrometer prototype have shown a frequency accuracy comparable to that obtained with the commercial devices without facing the need for a large investment. Although the proposed FT-Raman prototype cannot be directly compared to the last generation of FT-Raman spectrometers from the commercial manufacturers, such a device could give an opportunity to users that require high frequency precision in their spectral analysis and are provided with rather scarce resources.
Who is Who? Joseph Fourier
(2015)
Mit längerfristigen Nutzerbefragungen in zwei unmittelbar benachbarten Bürogebäuden in Freiburg wurden das Temperaturempfinden der Nutzer und deren Zufriedenheit mit dem thermischen Raumkomfort zweimal täglich erfasst. Ein Bürogebäude wird im Sommer mit einem maschinellen Nachtlüftungskonzept konditioniert und das zweite verfügt über eine Betonkerntemperierung und eine Zu- und Abluftanlage. Auf Basis der vorhandenen Daten aus der Erhebung wurde mit Hilfe von Regressionsanalysen ein Modell zur Vorhersage der Komforttemperatur berechnet und mit den Modellen in DIN EN 15251 verglichen.
Die Kenntnis der Messunsicherheit verbessert die Aussagekraft von Einsatzhärtungstiefe-Messungen. Ausgehend von der Definition in der DIN EN ISO 2639:2002 wird unter Anwendung des „Guide to the Expression of Uncertainty in Measurement“ die Messunsicherheit abgeschätzt. Dazu werden die Einflüsse der Härteprüfung, der Positionierung der Prüfpunkte und der Probe berücksichtigt. Das Verfahren wird an zwei Beispielen angewendet: Zunächst werden die gemäß Norm zulässigen Toleranzen vollständig ausgenutzt, anschließend die Unsicherheit eines automatisierten Härteprüfers experimentell ermittelt. In beiden Fällen dominiert der Probeneinfluss das Ergebnis.
Mice and rats make up 95% of all animals used in medical research and drug discovery and development. Monitoring of physiological functions such as ECG, blood pressure, and body temperature over the entire period of an experiment is often required. Restraining of the animals in order to obtain this data can cause great inconvenience. The use of telemetric systems solves this problem and provides more reliable results. However, these devices are mostly equipped with batteries, which limit the time of operation or they use passive power supplies, which affects the operating range. The semi-passive telemetric implant being presented is based on RFID technology and overcomes these obstacles. The device is inductively powered using the magnetic field of a common RFID reader device underneath the cage, but is also able to operate for several hours autonomously. Being independent from the battery capacity, it is possible to use the implant over a long period of time or to re-use the device several times in different animals, thus avoiding the disadvantages of existing systems and reducing the costs of purchase and refurbishment.
Dieser Artikel beschreibt das vom Wissenschaftsministerium Baden-Württemberg geförderte Projekt bwLehrpool, welches zum Ziel hat, landesweit mittels Zentralisierung von Services und übergreifende Kooperationen IT-Kosten nachhaltig zu reduzieren und RZPersonal zu entlasten. Das Projekt umfasst die Schaffung einer zentralen Infrastruktur für PC-Pools, Speziallabore und e-Prüfungen, um eine größere Flexibilität für die ITUnterstützung in Lehre und Forschung zu erreichen. Dabei soll der administrative Aufwand für den Betrieb reduziert und gleichzeitig Lehre und Forschung von einem konkreten, rechnergestützten Arbeitsplatz beziehungsweise einer Räumlichkeit entkoppelt werden. Hierdurch lassen sich bestehende PC-Pools deutlich besser ausnutzen. Zudem sollen Software- und Hardwarekosten verringert werden, indem anders als derzeit, auch heterogene PC-Landschaften genutzt werden können. Der sich im Aufbau befindende Service leistet dabei eine doppelte Abstraktion. Einerseits schafft er ein gemeinsam nutzbares Basissystem, welches sich an die jeweiligen lokalen Gegebenheiten wie Benutzerverwaltung, Home- und gemeinsame Verzeichnisse oder Druckdienste anpasst. Andererseits bietet es die notwendige Abstraktion, um virtuelle Maschinen verschiedenen Typs hochschulübergreifend nutzen zu können. Expertenwissen auf verschiedenen Ebenen wird optimal genutzt, und für die Lehrenden ergibt sich eine neue Perspektive, da sie auf einem einfachen Weg ihre Lehrund Forschungsumgebungen unabhängig von der konkreten Hardware- und Maschinenadministration definieren und gleichzeitig Erfahrungen mit anderen Hochschulen austauschen können.
Electrolyte-Gated Field-Effect Transistors Based on Oxide Semiconductors: Fabrication and Modeling
(2017)
Pressure dynamics in metal-oxygen (metal-air) batteries: a case study on sodium superoxide cells
(2014)
Electrochemical reactions in metal–oxygen batteries come along with the consumption or release of gaseous oxygen. We present a novel methodology for investigating electrode reactions and transport phenomena in metal–oxygen batteries by measuring the pressure dynamics in an enclosed gas reservoir above the oxygen electrode. The methodology is exemplified by a room-temperature sodium–oxygen battery forming sodium superoxide (NaO2) in an electrolyte of diethylene glycol dimethyl ether (diglyme) and sodium trifluoromethanesulfonate (NaOSO2CF3, NaOTf). The experiments are supported by microkinetic simulations with a one-dimensional multiphysics continuum model. During galvanostatic cycling over 30 cycles, a constant oxygen consumption/release rate is observed upon discharge/charge. The number of transferred electrons per oxygen molecule is calculated to 1.01 ± 0.02 and 1.03 ± 0.02 for discharge and charge, respectively, confirming the nature of the oxygen reaction product as superoxide O2–. The same ratio is observed in cyclic voltammetry experiments with low scan rate (<1 mV/s). However, at higher scan rates, the ratio increases as a result of oxygen transport limitations in the electrolyte. We introduce electrochemical pressure impedance spectroscopy (EPIS) for simultaneously analyzing current, voltage, and pressure of electrochemical cells. Pressure recording significantly increases the sensitivity of impedance toward oxygen transport properties of the porous electrode systems. In addition, we report experimental data on the diffusion coefficient and solubility of oxygen in electrolyte solutions as important parameters for the microkinetic models.