Refine
Year of publication
Document Type
- Conference Proceeding (156)
Conference Type
- Konferenz-Abstract (156) (remove)
Is part of the Bibliography
- yes (156)
Keywords
- RoboCup (13)
- Biomechanik (9)
- Heart rhythm model (5)
- Modeling and simulation (5)
- injury (5)
- Herzkrankheit (4)
- running (4)
- CST (3)
- HF-Ablation (3)
- Katheter (3)
- biomechanics (3)
- ACL (2)
- Abtragung (2)
- CRT (2)
- Cryoballoon catheter ablation (2)
- Defibrillator (2)
- Herzrhythmusmodell (2)
- Herzrhythmusstörung (2)
- Herzschrittmacher (2)
- Kardiale Resynchronisationstherapie (2)
- Signaltechnik (2)
- Supraventricular tachycardia (2)
- Synchronisierung (2)
- Vorhofflimmern (2)
- atrial fibrillation (2)
- cardiac ablation (2)
- heart rhythm model (2)
- 3D analysis (1)
- 3D print (1)
- AV nodal reentry tachycardia (1)
- AV reentrant tachycardia (1)
- Abwasser (1)
- Ageing (1)
- Artificial Intelligence (1)
- Atrial fibrillation (1)
- Austausch (1)
- Bestrahlung (1)
- Bioelektrochemische Brennstoffzelle (1)
- Biogas (1)
- Biogasreaktor (1)
- Bioimpedance measurement (1)
- Blended Learning (1)
- Brennstoffzelle (1)
- Business Intelligence (1)
- Cardiac resynchronization therapy (1)
- Dimensional Modelling (1)
- Durchblutung (1)
- Dünnschichtchromatographie (1)
- E-Learning (1)
- Electrochemistry (1)
- Electromagnetic and thermal simulation (1)
- Elektrizitätserzeugung (1)
- Elektrokardiogramm (1)
- Esophageal catheter (1)
- Eye tracking (1)
- Footwear (1)
- Gehirn (1)
- Hemodynamic monitoring (1)
- Herzmuskelkrankheit (1)
- High frequency ablation (1)
- Hochfrequenzablation (1)
- Hochfrequenztechnik (1)
- IVD (1)
- KAM (1)
- Kardiologie (1)
- Kernspintomografie (1)
- Kryoballonkatheter (1)
- Left Atrial Appendage Closure (1)
- Lithium-ion battery (1)
- Lumineszenz (1)
- M-learning (1)
- Materialermüdung (1)
- Medizintechnik (1)
- Methan (1)
- Methanisierung (1)
- Methanol (1)
- Mobile Learning (1)
- Modellierung und Simulation (1)
- Modelling (1)
- Multiside heart stimulation (1)
- Physik (1)
- Prothesen (1)
- Pulmonalvenenisolation (1)
- Pulmonary vein isolation (1)
- Qualitätskontrolle (1)
- Qualitätssicherung (1)
- Radiologie (1)
- Running (1)
- SAP Analytics Cloud (1)
- SAP Data Warehouse Cloud (1)
- Schleudertrauma (1)
- Schrittmacher (1)
- Simulation (1)
- Speiseröhre (1)
- Spinal cord stimulation (1)
- Sportmedizin (1)
- Steuerung (1)
- Synchronisationstherapie (1)
- Telemetrie (1)
- Transesophageal left atrial pacing (1)
- Verbrennungsmotor (1)
- Versorgung (1)
- Weitsprung (1)
- Wellenlänge (1)
- algorithm-based data analysis (1)
- athletic performance (1)
- atrial flutter (1)
- biomechanical stimulation (1)
- carbon elements (1)
- cushioning (1)
- cushioning (property) (1)
- customization (1)
- dickkopf 3 (1)
- echocardiography (1)
- elektrische Felder (1)
- force (1)
- heart rhythm simulation (1)
- high-speed cameras (1)
- impedance cardiography (1)
- kardiale Resynchronisationstherapie (1)
- mild traumatic brain injury (1)
- mobile web design guidelines (1)
- modeling (1)
- overuse (1)
- pulmonary vein isolation (1)
- remote laboratory (1)
- road and track running (1)
- running shoe (1)
- running shoes (1)
- signal averaging (1)
- sport (1)
- thermische Felder (1)
- three-dimensional kinematic (1)
- transversal skills (1)
- ventricular tachycardia (1)
- wavelet transformation (1)
- Überwachung (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (76)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (47)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (21)
- IBMS - Institute for Advanced Biomechanics and Motion Studies (ab 16.11.2022) (11)
- INES - Institut für nachhaltige Energiesysteme (10)
- POIM - Peter Osypka Institute of Medical Engineering (10)
- Fakultät Wirtschaft (W) (5)
- Fakultät Medien (M) (ab 22.04.2021) (1)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (1)
- IMLA - Institute for Machine Learning and Analytics (1)
Open Access
- Open Access (104)
- Closed Access (38)
- Bronze (35)
- Closed (11)
- Diamond (3)
Sweaty has already participated several times in RoboCup soccer competitions (Adult Size). Now the work is focused coordinating the play of two robots. Moreover, we are working on stabilizing the gait by adding additional sensor information. An ongoing work is the optimization of the control strategy by balancing between impedance and position control. By minimizing the jerk, gait and overall gameplay should improve significantly.
Artificial Intelligence (AI) can potentially transform many aspects of modern society in various ways, including automation of tasks, personalization of products and services, diagnosis of diseases and their treatment, transportation, safety, and security in public spaces, etc. Recently, AI technology has been transforming the financial industry, offering new ways to analyse data and automate processes, reduce costs, increase efficiency, and provide more personalized services to customers. However, it also raised important ethical and regulatory questions that need to be addressed by the industry and society as a whole. The aim of the Erasmus+ project Transversal Skills in Applied Artificial Intelligence - TSAAI (KA220-HED - Cooperation Partnerships in higher education) has been to establish a training platform that will incorporate teaching guidelines based on a curriculum covering different areas of application of AI technology. In this work, we will focus on applying AI models in the financial and insurance sectors.
Landing heel first has been associated with elevated external knee abduction moments (KAM), thereby potentially increasing the risk of sustaining a non-contact ACL injury. Apart from the foot strike angle, knee valgus angle (VAL) and vertical center of mass velocity at initial ground contact (IC) have been associated with increased KAM in females across different sidestep cuts. While real-time biofeedback training has been proven effective for gait retraining [4], the highly dynamic, non-cyclical nature of cutting maneuvers makes real-time feedback unsuitable and alternative approaches necessary. This study aimed at assessing the efficacy of immediate software-aided feedback on cutting technique in reducing KAM during handball-specific cutting maneuvers.
Sweaty has already participated several times in RoboCup soccer competitions (Adult Size). Now the work is focused on stabilizing the gait. Moreover, we would like to overcome the constraints of a ZMP-algorithm that has a horizontal footplate as precondition for the simplification of the equations. In addition we would like to switch between impedance and position control with a fuzzy-like algorithm that might help to minimize jerks when Sweaty’s feet touch the ground.
Weitsprung mit und ohne Unterschenkelprothese – gleiche Sportart, unterschiedliche Disziplinen
(2022)
Objective: Dickkopf 3 (DKK3) has been identified as a urinary biomarker. Values above 4000 pg/mg creatinine (Cr) were linked with a higher risk of short-term decline of kidney function (J Am Soc Nephrol 29: 2722–2733). However, as of today, there is little experience with DKK3 as a risk marker in everyday clinical practice. We used algorithm-based data analysis to evaluate the potential dependence of DKK3 in a cohort from a large single center in Germany.
Method: DKK3 was measured in all CKD patients in our center October 1 st 2018 till Dec. 31 2019, together with calculated GFR (eGFR) and urinary albumin/creatinine ratio (UACR). Kidney transplant patients were excluded. Until the end of follow-up Dec 31 st 2021, repeated measurements were performed for all parameters. Data analysis was performed using MD-Explorer (BioArtProducts, Rostock, Germany) and Python with multiple libraries. Linear regression models were applied in patients for DKK3, eGFR and UACR. Comparison of the models was performed with a twosided Kolmogorov-Smirnov test.
Results: 1206 DKK3 measurements were performed in 1103 patients (621 male, age 70yrs, eGFR 29,41 ml/min/1.73qm, UACR 800 mg/g). 134 patients died during follow-up. DKK3 mean was 2905 pg/mg Cr (max. 20000, 75 % percentile 3800). 121 pts had DKK3 > 4000. At the end of follow-up 7 % of patients with DKK3 < 4000 (initial eGFR 17.6) versus 39.6 % of patients with DDK3 > 4000 (initial eGFR 15.7) underwent dialysis. Compared to eGFR and UACR at baseline, DKK3 > 4000 performed best to predict eGFR loss over the next 12 months.
Conclusion: In this cohort of CKD patients, DKK3 > 4000 at baseline predicted the eGFR slope better than eGFR or UACR at baseline. DKK3 > 4000 reflected a higher risk of progression towards ESRD in patients with similar baseline eGFR levels.
The majority of anterior cruciate ligament (ACL) injuries in team sports are non-contact injuries, with cutting maneuvers identified as high-risk tasks. Young female handball players have been shown to be at greater risk for ACL injuries than males. One risk factor for ACL injuries is the magnitude of the knee abduction moment (KAM). Cutting technique variables on foot placement, overall approach and knee kinematics have been shown to influence the KAM. Since injury risk is believed to increase with increasing task complexity, the purpose of the study was to test the effect of task complexity on technique variables that influence the KAM in female handball players during fake-and-cut tasks.
Electrode modelling and simulation of diagnostic and pulmonary vein isolation in atrial fibrillation
(2022)
Fallstudien sollen theoretische Lerninhalte zu Konzepten von Business Intelligence und Data Warehousing veranschaulichen und in einen praxisnahen Kontext bringen. Außerdem sollen Studierende umsetzungsorientierte Kompetenzen mit praxisrelevanten Systemen erwerben. Um diese Kompetenzen abzuprüfen und um die Auseinandersetzung mit Software und Konzepten zu vertiefen, haben sich Projekte als Ergänzung zu Fallstudien und Klausuren vielfach bewährt. Der Vortrag stellt dar, welche Möglichkeiten Dozierende im Rahmen der vom UCC zur Verfügung gestellten Plattform SAP Data Warehouse Cloud (SAP DWC) haben, um studentische Projekte zu Data Warehousing und Analytics durchzuführen. Der Autor berichtet über seine Erfahrung aus der Betreuung von über 30 Projekten mit SAP DWC aus verschiedenen Studiengängen seit 2020. Neben einer Übersicht über die von Studierenden gewählten Themen werden ausgewählte Projektergebnisse vorgestellt. Außerdem wird auf den Modus der Durchführung sowie existierende systemseitige Limitationen eingegangen. Für Dozierende, die mit ihren Studierenden eigene Projekte erfolgreich durchführen möchten, werden konkrete Hinweise und Maßnahmen dargestellt.
Patients with focal ventricular tachycardia are at risk of hemodynamic failure and if no treatment is provided the mortality rate can exceed 30%. Therefore, medical professionals must be adequately trained in the management of these conditions. To achieve the best treatment, the origin of the abnormality should be known, as well as the course of the disease. This study provides an opportunity to visualize various focal ventricular tachycardias using the Offenburg cardiac rhythm model.
Disturbances of the cardiac conduction system causing reentry mechanisms above the atrioventricular (AV) node are induced by at least one accessory pathway with different conducting properties and refractory periods. This work aims to further develop the already existing and continuously expanding Offenburg heart rhythm model to visualise the most common supraventricular reentry tachycardias to provide a better understanding of the cause of the respective reentry mechanism.
In bimodal cochlear implant (CI) / hearing aid (HA) users a constant interaural time delay in the order of several milliseconds occurs due to differences in signal processing of the devices. For MED-EL CI systems in combination with different HA types, we have quantified the respective device delay mismatch (Zirn et al. 2015). In the current study, we investigate the effect of the device delay mismatch in simulated and actual bimodal listeners on sound localization accuracy.
To deal with the device delay mismatch in actual bimodal listeners we delayed the CI stimulation according to the measured HA processing delay and two other values. With all delay values highly significant improvements of the rms error in the localization task were observed compared to the test without the delay. The results help to narrow down the optimal patient-specific delay value.
Spinal cord stimulation (SCS) is the most commonly used technique of neurostimulation. It involves the stimulation of the spinal cord and is therefore used to treat chronic pain. The existing esophageal catheters are used for temperature monitoring during an electrophysiology study with ablation and transesophageal echocardiography. The aim of the study was to model the spine and new esophageal electrodes for the transesophageal electrical pacing of the spinal cord, and to integrate them in the Offenburg heart rhythm model for the static and dynamic simulation of transesophageal neurostimulation. The modeling and simulation were both performed with the electromagnetic and thermal simulation software CST (Computer Simulation Technology, Darmstadt). Two new esophageal catheters were modelled as well as a thoracic spine based on the dimensions of a human skeleton. The simulation of directed transesophageal neurostimulation is performed using the esophageal balloon catheter with an electric pacing potential of 5 V and a trapezoidal signal. A potential of 4.33 V can be measured directly at the electrode, 3.71 V in the myocardium at a depth of 2 mm, 2.68 V in the thoracic vertebra at a depth of 10 mm, 2.1 V in the thoracic vertebra at a depth of 50 mm and 2.09 V in the spinal cord at a depth of 70 mm. The relation between the voltage delivered to the electrodes and the voltage applied to the spinal cord is linear. Virtual heart rhythm and catheter models as well as the simulation of electrical pacing fields and electrical sensing fields allow the static and dynamic simulation of directed transesophageal electrical pacing of the spinal cord. The 3D simulation of the electrical sensing and pacing fields may be used to optimize transesophageal neurostimulation.
The visualization of heart rhythm disturbance and atrial fibrillation therapy allow the optimization of new cardiac catheter ablations. With the simulation software CST (Computer Simulation Technology, Darmstadt) electromagnetic and thermal simulations can be carried out to analyze and optimize different heart rhythm disturbance and cardiac catheters for pulmonary vein isolation. Another form of visualization is provided by haptic, three-dimensional print models. These models can be produced using an additive manufacturing method, such as a 3D printer. The aim of the study was to produce a 3D print of the Offenburg heart rhythm model with a representation of an atrial fibrillation ablation procedure to improve the visualization of simulation of cardiac catheter ablation.
The basis of 3D printing was the Offenburg heart rhythm model and the associated simulation of cryoablation of the pulmonary vein. The thermal simulation shows the pulmonary vein isolation of the left inferior pulmonary vein with the cryoballoon catheter Arctic Front AdvanceTM from Medtronic. After running through the simulation, the thermal propagation during the procedure was shown in the form of different colors. The three-dimensional print models were constructed on the base of the described simulation in a CAD program. Four different 3D printers are available for this purpose in a rapid prototyping laboratory at the University of Applied Science Offenburg. Two different printing processes were used: 1. a binder jetting printer with polymer gypsum and 2. a multi-material printer with photopolymer. A final print model with additional representation of the esophagus and internal esophagus catheter was also prepared for printing.
With the help of the thermal simulation results and the subsequent evaluation, it was possible to make a conclusion about the propagation of the cold emanating from the catheter in the myocardium and the surrounding tissue. It could be measured that already 3 mm from the balloon surface into the myocardium the temperature drops to 25 °C. The simulation model was printed using two 3D printing methods. Both methods as well as the different printing materials offer different advantages and disadvantages. While the first model made of polymer gypsum can be produced quickly and cheaply, the second model made of photopolymer takes five times longer and was twice as expensive. On the other hand, the second model offers significantly better properties and was more durable overall. All relevant parts, especially the balloon catheter and the conduction, are realistically represented. Only the thermal propagation in the form of different colors is not shown on this model.
Three-dimensional heart rhythm models as well as virtual simulations allow a very good visualization of complex cardiac rhythm therapy and atrial fibrillation treatment methods. The printed models can be used for optimization and demonstration of cryoballoon catheter ablation in patients with atrial fibrillation.
Hintergrund: Die Pulmonalvenenisolation (PVI) mit Hilfe von Kryoballonkathetern ist eine anerkannte Methode zur Behandlung von Vorhofflimmern (AF). Diese Methode bietet eine kürzere Behandlungsdauer als die klassische Therapie durch die Hochfrequenzablation (HF). Ziel dieser Studie war es, verschiedene Kryoballonkatheter, HF-Katheter und Ösophaguskatheter in ein Herzrhythmusmodell zu integrieren und mittels statischer und dynamischer Simulation elektrische und thermische Felder bei PVI unter Vorhofflimmern zu untersuchen.
Methodik: Die Modellierung und Simulation erfolgte mit der elektromagnetischen und thermischen Simulationssoftware CST (CST Darmstadt). Zwei Kryoballons, ein HF-Ablationskatheter und ein Ösophaguskatheter wurden auf der Grundlage der technischen Handbücher der Hersteller Medtronic und Osypka modelliert. Der 23 mm Kryoballon und ein kreisförmiger Mappingkatheter wurden in das Offenburger Herzrhythmusmodell integriert, insbesondere die left inferior pulmonary vein (LIPV) zur Simulation der thermischen Feldausbreitung während einer PVI. Die Simulation einer PVI mit HF-Energie wurde mit dem integrierten HF-Ablationskatheter in der Nähe der LIPV durchgeführt. Der im Herzrhythmusmodell platzierte TO8 Ösophaguskatheter ermöglichte die Ableitung linksatrialer elektrischer Felder bei AF und die Analyse thermischer Felder während PVI.
Ergebnisse: Elektrische Felder konnten bei Sinusrhythmus und AF mit einem AF-Fokus in der LIVP statisch und dynamisch im Herzen und Ösophagus simuliert werden. Bei einer simulierten 20 Sekunden Applikation eines Kryoballon-Katheters bei -50°C wurde eine Temperatur von -24°C in einer Tiefe von 0,5 mm im Myokard gemessen. In einer Tiefe von 1 mm betrug die Temperatur -3°C, bei 2 mm Tiefe 18°C und bei 3 mm Tiefe 29°C. Unter der 15 sekündigen Anwendung eines HF-Katheters mit einer 8-mm-Elektrode und einer Leistung von 5 W bei 420 kHz betrug die Temperatur an der Spitze der Elektrode 110°C. In einer Tiefe von 0,5 mm im Myokard betrug die Temperatur 75°C, in einer Tiefe von 1 mm 58°C, in einer Tiefe von 2 mm 45°C und in einer Tiefe von 3 mm 38°C. Im Ösophagus konnte bei den meisten Simulationen eine konstante Temperatur von 37°C gemessen und die Gefahr einer Ösophagus-Fistel ausgeschlossen werden. Bei Kryoablation der LIPV wurde eine Abkühlung des Ösophagus auf 30°C gemessen.
Schlussfolgerungen: Die Herzrhythmussimulation elektrischer und thermaler Felder ermöglichen mit Anwendung unterschiedlicher Herzkatheter eine statische und dynamische Simulation von PVI durch Kryoablation, HF-Ablation und Temperaturanalyse im Ösophagus. Unter Einbeziehung von MRT- oder CT-Daten können elektrische und thermale Simulationen möglicherweise zur Optimierung von PVIs genutzt werden.
Background: The application of high-frequency ablation is used for the treatment of tachycardia arrhythmias and is a respected method. Ablation with high frequency current leads to the targeted heat destruction of myocardial tissue at specific sites and thus prevents the pathological propagation of excitation through these structures.
Purpose: The aim of this study was to simulate heat propagation during RF ablation with modeled electrodes in different sizes and materials. The simulation was performed on atrioventricular node re-entry tachycardia (AVNRT), atrioventricular re-entry tachycardia (AVRT) and atrial flutter (AFL).
Methods: Using the modeling and simulation software CST, ablation catheters with 4 mm and 8 mm tip electrodes were modeled from gold and platinum for each. The designed catheters correspond to the manufacturer"s specifications of Medtronic, Biotronik and Osypka. The catheters were integrated into the Offenburg heart rhythm model to simulate and compare the heat propagation during an ablation application, which also takes into account the blood flow in the four heart chambers. A power of 5 W - 40 W was simulated for the 4 mm electrodes and a power of 50 W - 80 W for the 8 mm electrodes.
Results: During the simulated HF ablation application, the temperature at the ablation electrode was measured at different powers. This is 40.67°C at 5 W, 44.34°C at 10 W, 51.76°C at 20 W, 59.0°C at 30 W, and 66.33°C at 40 W. The measured temperature during 40 W application is 39.5°C at 0,5 mm depth in the myocardium and 37.5°C at 2 mm depth.
In the simulation, the 8 mm platinum electrode reached an ablation temperature of 72.85°C at its tip during an applied power of 60 W. In contrast, the 8 mm platinum electrode reached a depth of 5 mm at 39.5 C° and at a depth of 2 mm at 37.5 °C. In contrast, the 8 mm gold electrode reached a temperature of 64.66°C with the same performance. This is due to the thermal properties of gold, which has a better thermal conductivity than platinum.
Conclusions: CST offers the possibility to carry out a static and dynamic simulation of a heart model and the ablation electrodes integrated in it during an HF ablation. In variation with different electrode sizes and materials, therapy methods for the treatment of AVNRT, AVRT and AFL can be optimized
Background: Pulmonary vein isolation (PVI) using cryoballoon catheters are a recognized method for the treatment of atrial fibrillation (AF). This method offers shorter treatment duration in contrast to the classical therapy with high-frequency (HF) ablation.
Purpose: The aim of this study was to integrate different cryoballoon catheters and a HF catheter into a heart rhythm model and to compare them by means of static and dynamic electromagnetic and thermal simulation in use under AF.
Methods: The cryoballoon catheters from Medtronic and the HF ablation catheter from Osypka were modelled virtually with the aid of manufacturer specifications and the CST (Computer Simulation Technology, Darmstadt) simulation program. The cryoballoon catheter was located in the lower left pulmonary vein of the virtual heart rhythm model for the realization of pulmonary vein isolation (PVI) by cryoenergy. The simulated temperature at the balloon surface was -50°C during the simulation.
Results: During a simulated 20 second application of a cryoballoon catheter at -50°C, a temperature of -24°C was measured at a depth of 0.5 mm in the myocardium. At a depth of 1 mm the temperature was -3°C, at 2 mm depth 18°C and at 3 mm depth 29°C. Under the 15 second application of a RF catheter with a 8 mm electrode and a power of 5 W at 420 kHz, the temperature at the tip of the electrode was 110°C. At a depth of 0.5 mm in the myocardium, the temperature was 75°C, at a depth of 1 mm 58°C, at 2 mm depth 45°C and at 3 mm depth 38°C.
Conclusions: The simulation of temperature profiles during the virtual application of several catheter models in the heart rhythm model allows the static and dynamic simulation of PVI by cryoballoon ablation and RF ablation. The three-dimensional simulation can be used to improve ablation applications by creating a model in personalized cardiac rhythm therapy from MRI or CT data of a heart and finding a favourable position for ablation of AF.
Background: Transesophageal left atrial (LA) pacing and transesophageal LA ECG recording are semi-invasive techniques for diagnostic and therapy of supraventricular rhythm disturbance. Cardiac resynchronization therapy (CRT) with right atrial (RA) sensed biventricular pacing is an established therapy for heart failure patients with reduced left ventricular (LV) ejection fraction, sinus rhythm and interventricular electrical desynchronization.
Purpose: The aim of the study was to evaluate electromagnetic and voltage pacing fields of the combination of RA pacing, LA pacing and biventricular pacing in patients with long interatrial and interventricular electrical desynchronization.
Methods: The modelling and electromagnetic simulations of transesophageal LA pacing in combination with RA pacing and biventricular pacing would be staged and analyzed with the CST (Computer Simulation Technology) software. Different electrodes were modelled in order to simulate different types of bipolar pacing in the 3D-CAD Offenburg heart rhythm model: The bipolar Solid S (Biotronik) electrode where modelled for RA pacing and right ventricular (RV) pacing, Attain 4194 (Medtronic) for LV pacing and TO8 (Osypka) multipolar esophageal electrode with hemispheric electrodes for LA pacing.
Results: The pacemaker amplitudes for the electromagnetic pacing simulations were performed with 3 V for RA pacing, 1.5 V for RV pacing, 50 V for LA pacing and 3V for LV pacing with pacing impulse duration of 0.5 ms for RA, RV and LV pacing and 10 ms for LA pacing. The atrioventricular pacing delay after RA pacing was 140 ms. The different pacing modes AAI, VVI, DDD, DDD0V and DDD0D were evaluated for the analysis of the electric pacing field propagation of pacemaker, CRT and LA pacing. The pacing results were compared at minimum (LOW) and maximum (HIGH) parameter settings. While the LOW setting produced fewer tetrahedral and more inaccurate results, the HIGH setting produced many tetrahedral and therefore more accurate results.
Conclusions: The simulation of the combination of transesophageal LA pacing with RA sensed biventricular pacing is possible with the Offenburg heart rhythm model. The new temporary 4-chamber pacing method may be additional useful method in CRT non-responders with long interatrial electrical delay.