Refine
Year of publication
- 2018 (13) (remove)
Document Type
- Article (reviewed) (13) (remove)
Has Fulltext
- no (13) (remove)
Is part of the Bibliography
- yes (13)
Keywords
- cardiac resynchronization therapy (2)
- 3D modeling (1)
- 3d Heart Simulation (1)
- Alexander von Humboldt (1)
- Catheter Ablation (1)
- Cyclic plasticity (1)
- Eisenguss (1)
- Electrode Model (1)
- Gray cast iron (1)
- HF Ablation (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (6)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (3)
- INES - Institut für nachhaltige Energiesysteme (2)
- ACI - Affective and Cognitive Institute (1)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (1)
- Fakultät Wirtschaft (W) (1)
Open Access
- Open Access (13) (remove)
In the 19th century Alexander von Humboldt explored the nature and was conceived a new vision of nature that still influences the way we understand the new world. Humboldt believed in the importance of accurate measurements and precise description of observations. His vision of nature included not only facts but also emotions.
Nowadays smart solutions will be developed by using computer technology, which will influence our relationship to nature, our handling of the complexity and diversity of nature itself and the technological influences on the society. Could we avoid a new form of “Colonialism”, when a network of super computers will create a smarter world?
Nonlinearity can give rise to intermodulation distortions in surface acoustic wave (SAW) devices operating at high input power levels. To understand such undesired effects, a finite element method (FEM) simulation model in combination with a perturbation theory is applied to find out the role of different materials and higher order nonlinear tensor data for the nonlinearities in such acoustic devices. At high power, the SAW devices containing metal, piezoelectric substrate, and temperature compensating (TC) layers are subject to complicated geometrical, material, and other nonlinearities. In this paper, third-order nonlinearities in TC-SAW devices are investigated. The materials used are LiNbO 3 -rot128YX as the substrate and copper electrodes covered with a SiO 2 film as the TC layer. An effective nonlinearity constant for a given system is determined by comparison of nonlinear P-matrix simulations to third-order intermodulation measurements of test filters in a first step. By employing these constants from different systems, i.e., different metallization ratios, in nonlinear periodic P-matrix simulations, a direct comparison to nonlinear periodic FEM-simulations yields scaling factors for the materials used. Thus, the contribution of the different materials to the nonlinear behavior of TC-SAW devices is obtained and the role of metal electrodes, substrate, and TC film are discussed in detail.
Lithium-ion pouch cells with lithium titanate (Li4Ti5O12, LTO) anode and lithium nickel cobalt aluminum oxide (LiNi0.8Co0.15Al0.05O2, NCA) cathode were investigated experimentally with respect to their electrical (0.1C…4C), thermal (5 °C…50 °C) and long-time cycling behavior. The 16 Ah cell exhibits an asymmetric charge/discharge behavior which leads to a strong capacity-rate effect, as well as a significantly temperature-dependent capacity (0.37 Ah ∙ K−1) which expresses as additional high-temperature feature in the differential voltage plot. The cell was cycled for 10,000 cycles inbetween the nominal voltage limits (1.7–2.7 V) with a symmetric 4C constant-current charge/discharge protocol, corresponding to approx. 3400 equivalent full cycles. A small (0.192 mΩ/1000 cycles) but continuous increase of internal resistance was observed. Using electrochemical impedance spectroscopy (EIS), this could be identified to be caused by the NCA cathode, while the LTO anode showed only minor changes during cycling. The temperature-corrected capacity during 4C cycling exhibited a decrease of 1.28%/1000 cycles. The 1C discharge capacity faded by only 4.0% for CC discharge and 2.3% for CCCV discharge after 10,000 cycles. The cell thus exhibits very good internal-resistance stability and excellent capacity retention even under harsh (4C continuous) cycling, demonstrating the excellent stability of LTO as anode material.
One of the bottlenecks hindering the usage of polymer electrolyte membrane fuel cell technology in automotive applications is the highly load-sensitive degradation of the cell components. The cell failure cases reported in the literature show localized cell component degradation, mainly caused by flow-field dependent non-uniform distribution of reactants. The existing methodologies for diagnostics of localized cell failure are either invasive or require sophisticated and expensive apparatus. In this study, with the help of a multiscale simulation framework, a single polymer electrolyte membrane fuel cell (PEMFC) model is exposed to a standardized drive cycle provided by a system model of a fuel cell car. A 2D multiphysics model of the PEMFC is used to investigate catalyst degradation due to spatio-temporal variations in the fuel cell state variables under the highly transient load cycles. A three-step (extraction, oxidation, and dissolution) model of platinum loss in the cathode catalyst layer is used to investigate the cell performance degradation due to the consequent reduction in the electro-chemical active surface area (ECSA). By using a time-upscaling methodology, we present a comparative prediction of cell end-of-life (EOL) under different driving behavior of New European Driving Cycle (NEDC) and Worldwide Harmonized Light Vehicles Test Cycle (WLTC).
A Validated Quantification of Sudan Red Dyes in Spicery using TLC and a 16-bit Flatbed Scanner
(2018)
We present a video-densitometric quantification method for Sudan red dyes in spices and spice mixtures, separated by TLC. Application was done band-wise in small dots using a 5 μL glass pipette. For separation, the RP-18 plates (20 × 20 cm with fluorescent dye; Merck, Germany, 1.05559) were developed in a vertical developing chamber without vapor saturation from the starting point to a distance of 70 mm by using acetonitrile, methanol, and aqueous ammonia solution (25%; 8 + 1.8 + 0.2, v/v) as mobile phase. The quantification is based on direct measurements using an inexpensive 16-bit flatbed scanner for color measurements (in red, green, and blue). Evaluation of only the green channel makes the measurements very specific. For linearization, an extended Kubelka-Munk expression for data transformation was used. The range of linearity covers more than two magnitudes and lies between 20 and 500 ng. The extraction from a 2 g sample with acetonitrile, evaporation, and reconstitution to 200 μL with methanol and the band-wise application (7 mm) of a 10 μL sample allows a statistically defined LOD of less than 500 ppb of Sudan red dyes. To perform the analysis, a separation chamber, RP-18 plates, 5 μL glass pipettes, and a 16-bit flatbed scanner for 105 € are needed; therefore, the separation method is inexpensive, fast, and reliable.
In this article, we present a taxonomy in Robot-Assisted Training; a growing body of research in Human–Robot Interaction which focuses on how robotic agents and devices can be used to enhance user’s performance during a cognitive or physical training task. Robot-Assisted Training systems have been successfully deployed to enhance the effects of a training session in various contexts, i.e., rehabilitation systems, educational environments, vocational settings, etc. The proposed taxonomy suggests a set of categories and parameters that can be used to characterize such systems, considering the current research trends and needs for the design, development and evaluation of Robot-Assisted Training systems. To this end, we review recent works and applications in Robot-Assisted Training systems, as well as related taxonomies in Human–Robot Interaction. The goal is to identify and discuss open challenges, highlighting the different aspects of a Robot-Assisted Training system, considering both robot perception and behavior control.
In this paper the yield surface of a recently presented microstructure-based volume element of the gray cast iron material GJL-250 is assessed after different plastic loading histories. The evolution of the yield surface is investigated for different volumetric, deviatoric and uniaxial loadings. The micromechanical material properties of the metallic matrix and the graphite inclusions are validated by means experimental stress-strain hysteresis loops. The metallic matrix is modeled as elastic-plastic with a non-linear kinematic hardening law. The graphite inclusions are described by means of a volumetric strain state dependent Young’s modulus. The results show that the shape of the yield surface does not change significantly in comparison to the initial yield surface after pure deviatoric loadings. After volumetric loadings, the dependence of the material on the Lode angle is significantly reduced. Uniaxial tensile preloadings result in a deformed yield surface, whereby the magnitude of the deformation depends on the applied load. Uniaxial preloadings to compression do not change the shape of the initial yield surface.
Die Hersteller von Cochlea-Implantat (CI)-Systemen sehen für klinische Audiologen die Möglichkeit vor, die Mikrofonleistung der meisten aktuellen CI-Sprachprozessoren mittels anschließbarer Monitorkopfhörer zu prüfen. Nähere Angaben dazu, nach welchem Prozedere diese Prüfung stattfinden soll, z. B. welche Stimuli mit welchen Pegeln verwendet werden sollen, sind nach Wissen der Autoren seitens der CI-Hersteller nicht verfügbar. Auf der Basis dieser subjektiven Prüfung entscheidet dann der Audiologe, ob der betreffende Sprachprozessor an den Hersteller eingeschickt wird oder nicht. Wir haben eine Messbox entwickelt, mit der die Mikrofonleistung aller abhörbaren CI-Sprachprozessoren der Hersteller Advanced Bionics, Cochlear und MED-EL objektiv geprüft werden kann. Die Box wurde im 3-D-Druckverfahren hergestellt. Der zu prüfende Sprachprozessor wird in die Messbox eingehängt und über einen verbauten Lautsprecher mit definierten Prüfsignalen (Sinustönen unterschiedlicher Frequenz) beschallt. Das Signal des Mikronfons bzw. der Mikrofone wird über das in der Audio-/Abhörbuchse des Prozessors eingesteckte Kabel der Monitorkopfhörer herausgeführt und mit einer Shifting and Scaling-Schaltung in einen Spannungsbereich transformiert, der für die A/D-Wandlung mit einem Mikrokontroller (ATmega1280 verbaut auf einem Arduino Mega) geeignet ist. Derselbe Mikrokontroller übernimmt über einen eigens gebauten D/AWandler die Ausgabe der Prüfsignale über den Lautsprecher. Signalaufnahme und –wiedergabe erfolgt jeweils mit einer Samplingrate von 38,5 kHz. Der frequenzspezifische Effektivwert des abgegriffenen Mikrofonsignals wird mit einem Referenzwert verglichen. Die (frequenzspezifischen) Referenzwerte wurden mit einem neuwertigen Sprachprozessor gleichen Typs ermittelt und im Speicher des Mikrokontrollers abgelegt. Das Ergebnis wird nach Abschluss der Messung grafisch auf einem Touchscreen ausgegeben. Derzeit läuft eine erste Datenerhebung mit in der Klinik subjektiv auffällig gewordenen CI-Sprachprozessoren, die anschließend in der Messbox untersucht werden. Längerfristiges Ziel ist es, die hit und false alarm Raten der subjektiven Prüfung zu ermitteln.
Cardiac contractility modulation (CCM) is a device-based therapy for the treatment of systolic left ventricular chronic heart failure. Unlike other device-based therapies for heart failure, CCM delivers non-excitatory pacing signals to the myocardium. This leads to an extension of the action potential and to an improved contractility of the heart. The modeling and simulation was done with the electromagnetic simulation software CST. Three CCM electrodes were inserted into the Offenburg heart rhythm model and subsequently simulated the electric field propagation in CCM therapy.
In addition, simulations of CCM have been performed with electrodes from other device-based therapies, such as cardiac resynchronization therapy (CRT) and implantable cardioverter / defibrillator (ICD) therapy. At the same distance to the simulation electrode, the electric field is slightly stronger in CCM therapy than in CCM therapy with additionally implanted CRT or ICD electrodes. In addition, there is a change in the electric field propagation at the electrodes of the CRT and the shock electrode of the ICD.
By simulating several different therapy procedures on the heart, it is possible to check how they affect their behavior during normal operation. CCM heart rhythm model simulation allows the evaluation the individual electrical pacing and sensing field during CCM.