Refine
Year of publication
Document Type
- Conference Proceeding (453) (remove)
Conference Type
- Konferenzartikel (288)
- Konferenz-Abstract (76)
- Konferenzband (57)
- Sonstiges (23)
- Konferenz-Poster (9)
Language
- English (303)
- German (148)
- Multiple languages (1)
- Russian (1)
Keywords
- Mikroelektronik (56)
- RoboCup (20)
- Kommunikation (7)
- Applikation (5)
- E-Learning (5)
- Eingebettetes System (5)
- Herzkrankheit (5)
- Brennstoffzelle (4)
- CST (4)
- Energieversorgung (4)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (453) (remove)
Open Access
- Open Access (234)
- Closed Access (151)
- Bronze (130)
- Closed (61)
- Diamond (1)
- Grün (1)
IPv6 over resource-constrained devices (6Lo) emerged as a de-facto standard for the Internet of Things (IoT) applications especially in home and building automation systems. We provide results of an investigation of the applicability of 6LoWPAN with RPL mesh networks for home and building automation use cases. The proper selection of Trickle parameters and neighbor reachable time-outs is important in the RPL protocol suite to respond efficiently to any path failure. These parameters were analyzed in the context of energy consumption w.r.t the number of control packets. The measurements were performed in an Automated Physical Testbeds (APTB). The results match the recommendation by RFC 7733 for selecting various parameters of RPL protocol suite. This paper shows the relationship between various RPL parameters and control traffic overhead during network rebuild. Comparative measurement results with Bluetooth Low Energy (BLE) in this work showed that 6Lo with RPL outperformed BLE in this use case with less control traffic overheads.
In this work, we consider a duty-cycled wireless sensor network with the assumption that the on/off schedules are uncoordinated. In such networks, as all nodes may not be awake during the transmission of time synchronization messages, nodes will require to re-transmit the synchronization messages. Ideally a node should re-transmit for the maximum sleep duration to ensure that all nodes are synchronized. However, such a proposition will immensely increase the energy consumption of the nodes. Such a situation demands that there is an upper bound of the number of retransmissions. We refer to the time a node spends in re-transmission of the control message as broadcast duration. We ask the question, what should be the broadcast duration to ensure that a certain percentage of the available nodes are synchronized. The problem to estimate the broadcast duration is formulated so as to capture the probability threshold of the nodes being synchronized. Results show the proposed analytical model can predict the broadcast duration with a given lower error margin under real world conditions, thus demonstrating the efficiency of our solution.
The ability to detect a signal masked by noise is improved in normal-hearing (NH) listeners when interaural phase differences (IPD) between the ear signals exist either in the masker or the signal. We determined the impact of different coding strategies in bilaterally implanted cochlear implant (BiCI) users with and without fine-structure coding (FSC) on masking level differences. First, binaural intelligibility level differences (BILD) were determined in NH listeners and BiCI users using their clinical speech processors. NH subjects (n=8) showed a significant mean BILD of 7.5 dB. In contrast, BiCI users (n=9) without FSC as well as with FSC revealed a barely significant mean BILD (0.4 dB respectively 0.6 dB). Second, IPD thresholds were measured in BiCI users using either their speech processors with FS4 or direct stimulation with FSC. With the latter approach, synchronized stimulation providing an interaural accuracy of stimulation timing of 1.67 µs was realized on pitch matched electrode pairs. The resulting individual IPD threshold was lower in most of the subjects with direct stimulation than with their speech processors. These outcomes indicate that some BiCI users can benefit from increased temporal precision of interaural FSC and adjusted interaural frequency-place mapping presumably resulting in improved BILD.
NEXCODE is a project promoted by the European Space Agency aimed at research design development and demonstration of a receiver chain for telecomm and links in space missions including the presence of new short low-density parity-check codes for error correction. These codes have excellent performance from the error rate viewpoint but also put new challenges as regards synchronization issues and implementation. In this paper after a short review of the results obtained through numerical simulations we present an overview of the breadboard designed for practical testing and the test-plan proposed for the verification of the breadboard and the validation of the new codes and novel synchronization techniques under relevant operation conditions.
This work describes a non-parametric camera-based method for the calibration of Optical See-Through Glasses (OSTG). Existing works model the optical system through perspective projection and parametric functions. In the border areas of the displays such models are often inadequate. Moreover, rigid calibration patterns, that produce only a small amount of non-equidistant point correspondences, are used. In order to overcome these disadvantages every single display pixel is calibrated individually. The error prone user interaction is avoided by using cameras placed behind the displays of the OSTG. The displays show a shifting pattern that is used to calculate the pixels' locations. A camera mounted rigidly on the OSTG is used to find the relations between the system components. The obtained results show better accuracies than in previous works and prove that a second calibration step for user adaptation is necessary for high accuracy applications.
Die Vielfalt der Protokolle, die praktisch auf allen Ebenen der Netzwerkkommunikation zu berücksichtigen ist, stellt eine der großen Herausforderungen bei der fortschreitenden Automatisierung des intelligenten Hauses dar. Unter dem Überbegriff Internet der Dinge (Internet of Things) entstehen gegenwärtig zahlreiche neue Entwicklungen, Standards, Allianzen und so genannte Ökosysteme. Diese haben die Absicht einer horizontalen Integration gewerkeübergreifender Anwendungen und verfolgen fast alle das Ziel, die Situation zu vereinfachen, die Entwicklungen zu beschleunigen und Markterfolge zu erreichen. Leider macht diese Vielfalt momentan die Welt aber eher noch komplexer und bringt damit das Risiko mit sich, genau das Gegenteil der ursprünglichen Absichten zu erreichen. Dieser Beitrag versucht, die Entwicklungen möglichst systematisch zu kategorisieren und mögliche Lösungsansätze zu beschreiben.
High mobility, electrolyte-gated transistors (EGTs) show high DC performance at low voltages (< 2 V). To model those EGTs, we have used different models for the below and the above threshold regime with appropriate interpolation to ensure continuity and smoothness over all regimes. This empirical model matches very well with our measured results obtained by the electrical characterization of EGTs.
Wireless sensor networks have found their way into a wide range of applications among which environmental monitoring systems have attracted increasing interests of researchers. The main challenges for the applications are scalability of the network size and energy efficiency of the spatially distributed motes. These devices are mostly battery-powered and spend most of their energy budget on the radio transceiver module. A so-called Wake-On-Radio (WOR) technology can be used to achieve a reasonable balance among power consumption, range, complexity and response time. In this paper, a novel design for integration of WOR into IEEE802.1.5.4 is presented, which flexibly allows trade-offs in energy consumption between sender and receiver station, between real-time capability and energy consumption. For identical behavior, the proposed scheme is significantly more efficient than other schemes, which were proposed in recent publications, while preserving backward compatibility with standard IEEE802.15.4 transceivers.
Ultra wide band (UWB) signals are well suited both for short-range wireless communication and for high-precision localization applications. Channel impulse response (CIR) analysis in UWB systems is a major element in localization estimation. In this paper, practical aspects of CIR are presented. I.e. a technique for the construction of the accumulated echo-gram of a multipath delayed signal is proposed. Decawave hardware was used to demonstrate the technique of analysis of fine structure of signals with a sub-nanosecond resolution. Temporal stability, reliability and two-way characteristics of such echo-grams are discussed as well. The results of using two EVK1000 radio modules as a radar installation to detect a target in indoor environments prove that a low cost UWB intrusion detection and through-the-wall-vision systems might be developed using the proposed technique.
In the work at hand, we combine a Private Information Retrieval (PIR) protocol with Somewhat Homomorphic Encryption (SHE) and use Searchable Encryption (SE) with the objective to provide security and confidentiality features for a third party cloud security audit. During the auditing process, a third party auditor will act on behalf of a cloud service user to validate the security requirements performed by a cloud service provider. Our concrete contribution consists of developing a PIR protocol which is proceeding directly on a log database of encrypted data and allowing to retrieve a sum or a product of multiple encrypted elements. Subsequently, we concretely apply our new form of PIR protocol to a cloud audit use case where searchable encryption is employed to allow additional confidentiality requirements to the privacy of the user. Exemplarily we are considering and evaluating an audit of client accesses to a controlled resource provided by a cloud service provider.
Agile Business Intelligence als Beispiel für ein domänenspezifisch angepasstes Vorgehensmodell
(2016)
Business-Intelligence-Systeme stellen durch ihre Unterstützung bei der Entscheidungsfindung für Unternehmen eine wichtige Rolle dar. Mit einer stetig dynamischeren Unternehmensumwelt geht daher die Anforderung nach der agilen Entwicklung dieser Systeme einher, so dass in der BI-Domäne zunehmend erfolgreich agile Methoden und Vorgehensmodelle eingesetzt werden. Die Weiterentwicklung und Anpassung von BI-Systemen ist dahingehend besonders, dass diese in der Regel langjährig gewachsenen Systemen und Strukturen betreffen, die strengen regulatorischen Rahmenbedingungen unterliegen, was eine Herausforderung für agile Vorgehensweisen darstellt. Wurden die Werte und Prinzipien des agilen Manifests [AM01] und die daraus abgeleiteten Methoden zu Beginn meist eins zu eins auf den Bereich BI übertragen, so hat sich das Verständnis von BI- Agilität als ganzheitliche Eigenschaft der BI im deutschsprachigen Raum etabliert, und agile Me- thoden wurden auf die Besonderheiten der BI-Domäne adaptiert. In diesem Beitrag werden BI-Agilität und Agile BI erläutert, ein Ordnungsrahmen für Maßnahmen zur Steigerung der BI-Agilität eingeführt sowie Herausforderungen bei Agile BI erläutert.
Institute of Reliable Embedded Systems and Communication Electronics, Offenburg University of Applied Sciences, Germany has developed an automated testing environment, Automated Physical TestBeds (APTB), for analyzing the performance of wireless systems and its supporting protocols. Wireless physical networking nodes can connect to this APTB and the antenna output of this attaches with the RF waveguides. To model the RF environment this RF waveguides then establish wired connection among RF elements like splitters, attenuators and switches. In such kind of set up it’s well possible to vary the path characteristics by altering the attenuators and switches. The major advantage of using APTB is the possibility of isolated, well controlled, repeatable test environment in various conditions to run statistical analysis and even to execute regression tests. This paper provides an overview of the design and implementation of APTB, demonstrates its ability to automate test cases, and its efficiency.
Due to a controversial enrollment policy in most engineering programs at German Universities of Applied Sciences (UAS), many freshmen show very low school grades in key subjects like Math and Physics. Nevertheless they expect to be entertained in the lectures and get demotivated easily. Despite initial reservations, a cheer-and-challenge approach was developed for teaching Mechanics to freshmen having very diverse school grades. When tested, it showed astonishing results.
IPv6 over LoRaWAN™
(2016)
Although short-range wireless communication explicitly targets local and regional applications, range continues to be a highly important issue. The range directly depends on the so-called link budget, which can be increased by the choice of modulation and coding schemes. The recent transceiver generation in particular comes with extensive and flexible support for software-defined radio (SDR). The SX127× family from Semtech Corp. is a member of this device class and promises significant benefits for range, robust performance, and battery lifetime compared to competing technologies. This contribution gives a short overview of the technologies to support Long Range (LoRa™) and the corresponding Layer 2 protocol (LoRaWAN™). It particularly describes the possibility to combine the Internet Protocol, i.e. IPv6, into LoRaWAN™, so that it can be directly integrated into a full-fledged Internet of Things (IoT). The proposed solution, which we name 6LoRaWAN, has been implemented and tested; results of the experiments are also shown in this paper.
Battery degradation is a complex physicochemical process that strongly depends on operating conditions and environment. We present a model-based analysis of lithium-ion battery degradation in smart microgrids, in particular, a single-family house and an office tract with photovoltaics generator. We use a multi-scale multi-physics model of a graphite/lithium iron phosphate (LiFePO4, LFP) cell including SEI formation as ageing mechanism. The cell-level model is dynamically coupled to a system-level model consisting of photovoltaics, inverter, power consumption profiles, grid interaction, and energy management system, fed with historic weather data. The behavior of the cell in terms of degradation propensity, performance, state of charge and other internal states is predicted over an annual operation cycle. As result, we have identified a peak in degradation rate during the battery charging process, caused by charging overpotentials. Ageing strongly depends on the load situation, where the predicted annual capacity fade is 1.9 % for the single-family house and only 1.3 % for the office tract.
Wireless communication systems more and more become part of our daily live. Especially with the Internet of Things (IoT) the overall connectivity increases rapidly since everyday objects become part of the global network. For this purpose several new wireless protocols have arisen, whereas 6LoWPAN (IPv6 over Low power Wireless Personal Area Networks) can be seen as one of the most important protocols within this sector. Originally designed on top of the IEEE802.15.4 standard it is a subject to various adaptions that will allow to use 6LoWPAN over different technologies; e.g. DECT Ultra Low Energy (ULE). Although this high connectivity offers a lot of new possibilities, there are several requirements and pitfalls coming along with such new systems. With an increasing number of connected devices the interoperability between different providers is one of the biggest challenges, which makes it necessary to verify the functionality and stability of the devices and the network. Therefore testing becomes one of the key components that decides on success or failure of such a system. Although there are several protocol implementations commonly available; e.g., for IoT based systems, there is still a lack of according tools and environments as well as for functional and conformance testing. This article describes the architecture and functioning of the proposed test framework based on Testing and Test Control Notation Version 3 (TTCN-3) for 6LoWPAN over ULE networks.
In the last decade, IPv6 over Low power Wireless Personal Area Networks (IEEE802.15.4), also known as 6LoWPAN, has well evolved as a primary contender for short range wireless communications and holds the promise of an Internet of Things, which is completely based on the Internet Protocol. The authors' team has developed a 6LoWPAN protocol stack in C language, the stack without the necessity to use a specific design environment or operating system. It is highly flexible, modular, and portable and can be enhanced by several interesting modules, like a Wake-On-Radio-(WOR) MAC layer or a TLS1.2 based security sublayer. The stack is made available as open source at https://github.com/hso-esk/emb6. It was extensively tested on the Automated Physical Testbed (APTB) for Wireless Systems, which is available in the authors' lab and allows a flexible setup and full control of arbitrary topologies. The results of the measurements demonstrate a very good stability and short-term with long-term performance also under dynamic conditions.
BiCI users’ sensitivity to interaural phase differences for single- and multi-channel stimulation
(2016)
Die Verwendung von Kameras als Messmittel für medizinische Anwendungen setzt deren präzise Kalibrierung voraus. Gängige Verfahren modellieren die Abbildungseigenschaften einer Kamera mittels perspektivischer Projektion und parametrisierter Funktionen zur Beschreibung von Linsenverzerrung. In den Randbereichen des Kamerabildes sind diese Modelle oft unzureichend. Außerdem bedingt die Verwendung starrer Kalibriermuster eine in der Regel kleine Anzahl an nicht gleichmäßig verteilten Punktkorrespondenzen zur Bestimmung der Modellparameter. In der vorliegenden Arbeit wird ein vollkommen neues und nicht auf Modellen basierendes Kalibrierverfahren vorgestellt, bei dem jedes Kamerapixel unabhängig von jedem anderen kalibriert wird.
Energy and environment continue to be major issues of human mankind. This holds true on the regional, the national, and the global level. And it is one of the problems, where engineers and scientists in conjunction with political will and people's awareness, can find new approaches and solutions to save the natural resources and to make their use more efficient.
MPC-Workshop Februar 2016
(2016)
Die neueste Generation von programmierbaren Logikbausteinen verfügt neben den konfigurierbaren Logikzellen über einen oder mehrere leistungsfähige Mikroprozessoren. In dieser Arbeit wird gezeigt, wie ein bestehendes Zwei-Chip-System auf einen Xilinx Zynq 7000 mit zwei ARM A9-Cores migriert wird. Bei dem System handelt es sich um das „GPS-gestützte Kreisel-system ADMA“ des Unternehmens GeneSys. Die neue Lösung verbessert den Datenaustausch zwischen dem ersten Mikroprozessor zur digitalen Signalverarbeitung und dem zweiten Prozessor zur Ablaufsteuerung durch ein Shared Memory. Für die schnelle und echtzeitfähige Datenübertragung werden zahlreiche hochbitratige Schnittstellengenutzt.
This paper describes the new Sweaty II humanoid adult size robot trying to qualify for the RoboCup 2016 adult size humanoid competition. Based on experiences during RoboCup 2014, the Sweaty robot has been completely redesigned to a new robot Sweaty II. A major change is the use of linear actuators for the legs. Another characteristic is its indirect actuation by means of rods. This allows a variable transmission ratio depending on the angle of a joint.
The humanoid Sweaty was the finalist in this year’s robocup soccer championship(adult size). For the optimization of the gait and the stability, data concerning forces and torques in the ankle joints would be helpful. In the following paper the development of a six-axis force and torque sensor for the humanoid robot Sweaty is described. Since commercial sensors do not meet the demands for the sensors in Sweatys ankle joints, a new sensor was developed. As a measuring devices we used strain gauges and custom electronics based on an acam PS09. The geometry was analyzed with the FEM program ANSYS to get optimal dimensions for the measuring beams. In addition ANSYS was used to optimize the position for the strain gauges on the beam.
The Metering Bus, also known as M-Bus, is a European standard EN13757-3 for reading out metering devices, like electricity, water, gas, or heat meters. Although real-life M-Bus networks can reach a significant size and complexity, only very simple protocol analyzers are available to observe and maintain such networks. In order to provide developers and installers with the ability to analyze the real bus signals easily, a web-based monitoring tool for the M-Bus has been designed and implemented. Combined with a physical bus interface it allows for measuring and recording the bus signals. For this at first a circuit has been developed, which transforms the voltage and current-modulated M-Bus signals to a voltage signal that can be read by a standard ADC and processed by an MCU. The bus signals and packets are displayed using a web server, which analyzes and classifies the frame fragments. As an additional feature an oscilloscope functionality is included in order to visualize the physical signal on the bus. This paper describes the development of the read-out circuit for the Wired M-Bus and the data recovery.
Autonomous humanoid robots require light weight, high torque and high speed actuators to be able to walk and run. For conventional gears with a fixed gear ratio the product of torque and velocity is constant. On the other hand desired motions require maximum torque and speed. In this paper it is shown that with a variable gear ratio it is possible to vary the relation between torque and velocity. This is achieved by introducing systems of rods and levers to move the joints of our humanoid robot ”Sweaty II”. On the basis of a variable gear ratio low speed and high torque can be achieved for those joint angles, which require this motion mode, whereas high speed and low torque can be realized for those joint angles, where it is favorable for the desired motion.
Security in IT systems, particularly in embedded devices like Cyber Physical Systems (CPSs), has become an important matter of concern as it is the prerequisite for ensuring privacy and safety. Among a multitude of existing security measures, the Transport Layer Security (TLS) protocol family offers mature and standardized means for establishing secure communication channels over insecure transport media. In the context of classical IT infrastructure, its security with regard to protocol and implementation attacks has been subject to extensive research. As TLS protocols find their way into embedded environments, we consider the security and robustness of implementations of these protocols specifically in the light of the peculiarities of embedded systems. We present an approach for systematically checking the security and robustness of such implementations using fuzzing techniques and differential testing. In spite of its origin in testing TLS implementations we expect our approach to likewise be applicable to implementations of other cryptographic protocols with moderate efforts.
We propose secure multi-party computation techniques for the distributed computation of the average using a privacy-preserving extension of gossip algorithms. While recently there has been mainly research on the side of gossip algorithms (GA) for data aggregation itself, to the best of our knowledge, the aforementioned research line does not take into consideration the privacy of the entities involved. More concretely, it is our objective to not reveal a node's private input value to any other node in the network, while still computing the average in a fully-decentralized fashion. Not revealing in our setting means that an attacker gains only minor advantage when guessing a node's private input value. We precisely quantify an attacker's advantage when guessing - as a mean for the level of data privacy leakage of a node's contribution. Our results show that by perturbing the input values of each participating node with pseudo-random noise with appropriate statistical properties (i) only a minor and configurable leakage of private information is revealed, by at the same time (ii) providing a good average approximation at each node. Our approach can be applied to a decentralized prosumer market, in which participants act as energy consumers or producers or both, referred to as prosumers.
In online analytical processing (OLAP), filtering elements of a given dimensional attribute according to the value of a measure attribute is an essential operation, for example in top-k evaluation. Such filters can involve extremely large amounts of data to be processed, in particular when the filter condition includes “quantification” such as ANY or ALL, where large slices of an OLAP cube have to be computed and inspected. Due to the sparsity of OLAP cubes, the slices serving as input to the filter are usually sparse as well, presenting a challenge for GPU approaches which need to work with a limited amount of memory for holding intermediate results. Our CUDA solution involves a hashing scheme specifically designed for frequent and parallel updates, including several optimizations exploiting architectural features of Nvidia’s Fermi and Kepler GPUs.
Cardiac resynchronization therapy (CRT) is an established class I level A biventricular pacing therapy in chronic heart failure patients with left bundle branch block and reduced left ventricular ejection fraction, but not all patients improved clinically. Purpose of the study was to evaluate electrical interatrial conduction delay (IACD) to interventricular conduction delay (IVCD) ratio with focused transesophageal left atrial and left ventricular electrocardiography.
Methods: Thirty eight chronic heart failure patients (age 63.4±10.2 years; 3 females, 35 males) with New York Heart Association (NYHA) functional class 3.0±0.2 and 171.71±36.17ms QRS duration were analysed using posterior left atrial and left ventricular transesophageal electrocardiography with hemispherical electrodes before CRT. Electrical IACD was measured between onset of P-wave in the surface ECG and onset of left atrial signal. Electrical IVCD was measured between onset of QRS complex in the surface ECG and onset of left ventricular signal.
Results: Electrical IACD and IVCD could be evaluated by transesophageal left atrial and left ventricular electrocardiography in all heart failure patients with correlation to 1.18±0.92 IACD-IVCD-ratio (r=-0.57, P<0.001; r=0.66, P<0.001). There were 32 CRT responder with reduction of NYHA class from 3.0±0.22 to 1.97±0.31 (P<0.001) during 16.5±18.9 month CRT with 75.19±33.49ms IACD, 78.91±24.73ms IVCD, 1.04±0.66 IACD-IVCD-ratio and correlation between IACD and IACDIVCD- ratio (r=0.84, P<0.001). There were 6 CRT nonresponder with no reduction of NYHA class from 3.0±0.3 to 2.9±0.5 during 14.3±13.7 month biventricular pacing, 50.0±28.26ms IVCD (P=0.014), 1.92±1.65 IACD-IVCD-ratio (P=0,029) and correlation between 67.0±24.9ms IACD and IACD-IVCD-ratio (r=0.85, P=0.031).
Conclusions: Focused transesophageal left atrial and left ventricular electrocardiography can be utilized to analyse electrical IACD and IVCD in heart failure patients. IACDIVDC- ratio may be a useful parameter to evaluate electrical left cardiac desynchronization in heart failure patients.
Cardiac resynchronization therapy (CRT) is an established biventricular pacing therapy in heart failure patients with left bundle branch block and reduced left ventricular ejection fraction, but not all patients improved clinically as CRT responder. Purpose of the study was to evaluate electrical left atrial conduction delay (LACD) with focused transesophageal electrocardiography in CRT responder and CRT non-responder.
Methods: Twenty heart failure patients (age 66.6±8.2 years; 2 females, 18 males) with New York Heart Association functional class 3.0±0.3 and 174.2±40.2ms QRS duration were analysed using posterior left atrial transesophageal electrocardiography with hemispherical electrodes. Electrical LACD was measured between onset and offset of transesophageal left atrial signal before implantation of CRT devices.
Results: Electrical LACD could be evaluated by bipolar transesophageal left atrial electrocardiography using TO Osypka electrode in all heart failure patients with negative correlation between 54.7±18.1ms LACD and 24.9±6.4% left ventricular ejection fraction (r=-0.65, P=0.002). There were 16 CRT responders with reduction of New York Heart Association functional class from 3.0±0.29 to 2.1±0.2 (r=0.522, P=0.038) during 9.41±10.96 month biventricular pacing and negative correlation between 49.6±14.2ms LACD and 26.0±6.2% left ventricular ejection fraction (r=-0.533, P=0.034). There were 4 CRT non-responders with no reduction of New York Heart Association functional class from 3.0±0.4 to 2.8±0.5 (r=0.816, P=0.184) during with 13.88±16.39 month biventricular pacing and no correlation between 75.25±19.17ms LACD and 20.75±6.4% left ventricular ejection fraction (r=-0.831, P=0.169).
Conclusions: Focused transesophageal left atrial electrocardiography can be utilized to analyse electrical LACD in heart failure patients. LACD correlated negative with left ventricular ejection fraction in CRT responders. LACD may be a useful parameter to evaluate electrical left atrial desynchronization in heart failure patients.
Soccer simulation league is one of the founding leagues of RoboCup. In this paper we discuss the past, present and planned future achievements and changes. Also we summarize the connections and inter-league achievements of this league and provide an overview of the community contributions that made this league successful.
Im Projekt bwLehrpool wurde ein verteiltes System für die flexible Nutzung von Rechnerpools durch Desktop-Virtualisierung entwickelt. Auf Basis eines zentral gebooteten Linux- Grundsystems können beliebige virtualisierbare Betriebssysteme für Lehrund Prüfungszwecke zentral bereitgestellt und lokal auf den Maschinen aus-gewählt werden. Die verschiedenen Ar- beitsumgebungen müssen nicht mehr auf den PCs installiert werden und erlauben so eine multifunktionale Nutzung von PCs und Räumen für vielfältige Lehrund Lernszenarien sowie für elektronische Prüfungen. bwLehrpool abstrahiert von der PC-Hardware vor Ort und ermöglicht den Dozenten die eigene Gestaltung und Verwaltung ihrer Softwareumgebungen als Self-Service. Darüber hinaus fördert bwLehrpool den hochschulübergreifenden Austausch von Kursumgebungen.
6LoWPAN (IPv6 over Low Power Wireless Personal Area Networks) is gaining more and more attraction for the seamless connectivity of embedded devices for the Internet of Things (IoT). Whereas the lower layers (IEEE802.15.4 and 6LoWPAN) are already well defined and consolidated with regard to frame formats, header compression, routing protocols and commissioning procedures, there is still an abundant choice of possibilities on the application layer. Currently, various groups are working towards standardization of the application layer, i.e. the ETSI Technical Committee on M2M, the IP for Smart Objects (IPSO) Alliance, Lightweight M2M (LWM2M) protocol of the Open Mobile Alliance (OMA), and OneM2M. This multitude of approaches leaves the system developer with the agony of choice. This paper selects, presents and explains one of the promising solutions, discusses its strengths and weaknesses, and demonstrates its implementation.
6LoWPAN (IPv6 over Low Power Wireless Personal Area Networks) is gaining more and more attraction for the seamless connectivity of embedded devices for the Internet of Things. It can be observed that most of the available solutions are following an open source approach, which significantly leads to a fast development of technologies and of markets. Although the currently available implementations are in a pretty good shape, all of them come with some significant drawbacks. It was therefore decided to start the development of an own implementation, which takes the advantages from the existing solutions, but tries to avoid the drawbacks. This paper discussed the reasoning behind this decision, describes the implementation and its characteristics, as well as the testing results. The given implementation is available as open-source project under [15].
The application of leaky feeder (radiating) cables is a common solution for the implementation of reliable radio communication in huge industrial buildings, tunnels and mining environment. This paper explores the possibilities of leaky feeders for 1D and 2D localization in wireless systems based on time of flight chirp spread spectrum technologies. The main focus of this paper is to present and analyse the results of time of flight and received signal strength measurements with leaky feeders in indoor and outdoor conditions. The authors carried out experiments to compare ranging accuracy and radio coverage area for a point-like monopole antenna and for a leaky feeder acting as a distributed antenna. In all experiments RealTrac equipment based on nanoLOC radio standard was used. The estimation of the most probable path of a chirp signal going through a leaky feeder was calculated using the ray tracing approach. The typical non-line-of-sight errors profiles are presented. The results show the possibility to use radiating cables in real time location technologies based on time-of-flight method.
The demand of wireless solutions in industrial applications increases since the early nineties. This trend is not only ongoing, it is further pushed by developments in the area of software stacks like the latest Bluetooth Low Energy Stack. It is also pushed by new chip-designs and powerful and highly integrated electronic hardware. The acceptance of wireless technologies as a possible solution for industrial applications, has overcome the entry barrier [1]. The first step to see wireless as standard for many industrial applications is almost accomplished. Nevertheless there is nearly none acceptance of wireless technology for Safety applications. One highly challenging and demanding requirement is still unsolved: The aspect safety and robustness. Those topics have been addressed in many cases but always in a similar manner. WirelessHART as an example addresses this topic with redundant so called multiple propagation paths and frequency hopping to handle with interferences and loss of network participants. So far the pure peer to peer link is rarely investigated and there are less safety solutions available. One product called LoRa™ can be seen as one possible solution to address this lack of safety within wireless links. This paper focuses on the safety performance evaluation of a modem-chip-design. The use of diverse and redundant wireless technologies like LoRa can lead to an increase acceptance of wireless in safety applications. Many measurements in real industrial application have been carried out to be able to benchmark the new chip in terms of the safety aspects. The content of this research results can help to raise the level of confidence in wireless. In this paper, the term “safety” is used for data transmission reliability.
In this paper an RFID/NFC (ISO 15693 standard) based inductively powered passive SoC (system on chip) for biomedical applications is presented. A brief overview of the system design, layout techniques and verification method is dis-cussed here. The SoC includes an integrated 32 bit microcontroller, sensor interface circuit, analog to digital converter, integrated RAM, ROM and some other peripherals required for the complete passive operation. The entire chip is realized in CMOS 0.18 μm technology with a chip area of 1.52mm x 3.24 mm.
This paper presents a practice and science orientated education approach for freshman students of interdisciplinary bachelor engineering degree programs. This approach is meant to enhance the motivation and success of freshman students during their whole study. The education approach is called Fit4PracSis (Fit for Practice and Sciences) It was started to develop, set up and establish an education approach, which is building a relationship to students' future profession and to scientific working during the introductory study phase. The freshman students will be trained early in important skills, which are necessary for achieving the final degree successfully and handling of future business and research activities.
The aim of this research work was to develop a boiler model with few parameters required for energy planning. The showcase considered for this work was the boiler system of the energy center at Offenburg University of Applied Sciences. A grey box model of the boiler was developed systematically starting from model abstraction, simplification, model break-down and to the use of empirical correlations wherever necessary to describe the intermediate effects along with the use of information from manufacturer’s specification in order to reduce parameters. This strategy had resulted in a boiler model with only 6 parameters, namely, nominal burner capacity, water gallery capacity, air ratio, heat capacity of wall, thermal conductance on flue gas and hot water side. Most of these parameters can be obtained through the information available in the spec sheets and thus an energy planner will be able to parameterize the model with low effort. The model was validated with the monitored data of the showcase. It was tested for the start-up, shut-down behavior and the effect of storage.
Environmental Monitoring is an attractive application field for Wireless Sensor Network (WSN). Water Level Monitoring helps to increase the efficiency of water distribution and management. In Pakistan, the world’s largest irrigation system covers 90.000 km of channels which needs to be monitored and managed on different levels. Especially the sensor systems for the small distribution channels need to be low energy and low cost. The distribution presents a technical solution for a communication system which is developed in a research project being co-funded by German Academic Exchange Service (DAAD). The communication module is based on IEEE-802.15.4 transceivers which are enhanced through Wake-On-Radio (WOR) to combine low-energy and real-time behavior. On higher layers, IPv6 (6LoWPAN) and corresponding routing protocols like Routing Protocol for Low power and Lossy Networks (RPL) can extend range of the network. The data are stored in a database and can be viewed online via a web interface. Of course, also automatic data analysis can be performed.
We report the use of the Raman spectral information of the chemical compound toluene C7H8 as a reference on the analysis of laboratory-prepared and commercially acquired gasoline-ethanol blends. The rate behavior of the characteristic Raman lines of toluene and gasoline has enabled the approximated quantification of this additive in commercial gasoline-ethanol mixtures. This rate behavior has been obtained from the Raman spectra of gasoline-ethanol blends with different proportions of toluene.
All these Raman spectra have been collected by using a self-designed, frequency precise and low-cost Fourier-transform Raman spectrometer (FT-Raman spectrometer) prototype. This FT-Raman prototype has helped to accurately confirm the frequency position of the main characteristic Raman lines of toluene present on the different gasoline-ethanol samples analyzed at smaller proportions than those commonly found in commercial gasoline-ethanol blends. The frequency accuracy validation has been performed by analyzing the same set of toluene samples with two additional state-of-the-art commercial FT-Raman devices. Additionally, the spectral information has been contrasted, with highly-correlated coefficients as a result, with the values of the standard Raman spectrum of toluene.