Refine
Year of publication
Document Type
- Conference Proceeding (47)
- Contribution to a Periodical (13)
- Article (unreviewed) (4)
- Article (reviewed) (3)
- Book (3)
- Part of a Book (2)
- Image (1)
Conference Type
- Konferenzartikel (45)
- Sonstiges (2)
- Konferenz-Abstract (1)
- Konferenz-Poster (1)
Is part of the Bibliography
- yes (73)
Keywords
- Optik (7)
- Photonik (6)
- research-oriented education (5)
- Education in Optics and Photonics (4)
- Licht (4)
- optics and photonics (4)
- Education (3)
- VR (3)
- Virtuelle Realität (3)
- Astronomical events (2)
Institute
Open Access
- Open Access (37)
- Closed Access (19)
- Closed (5)
- Hybrid (5)
The authors explain a developed concept for research-oriented education in optics and photonics. It is presented which goals are to be achieved, which strategies have been developed and how these can be implemented in a blended learning scenario. The goal of our education is the best possible qualification of the students on the basis of a strong scientific and research-oriented education, which also includes the acquisition of important interdisciplinary competences. All phases of a research process are to be mapped in the learning process and offer students an insight into current research topics in optics and photonics.
Increased knowledge transfer through the integration of research projects into university teaching
(2019)
This paper describes the integration of the research project "Characterization of Color Vision using Spectroscopy and Nanotechnology: Application to Media Photonics" into an engineering course in the field of media technology. The aim is to develop the existing learning concept towards a more research-oriented teaching. Involving students in research projects as part of the learning process provides a deeper insight into current research topics and the key elements of scientific work. This makes it easier for students to recognize the importance of the acquired theoretical knowledge for the practice, which enables them to derive new insights of their own.
Redesigning a curriculum for teaching media technology is a major challenge. Up-to-date teaching and learning concepts are necessary that meet the constant technological progress and prepare students specifically for their professional life. Teaching and studying should be characterized by a student-oriented teaching and learning culture. In order to achieve this goal, consistent evaluation is essential. The aim of the evaluation concept presented here is to generate structured information regarding the quality of content-related, didactic and organizational aspects of teaching. The exchange of opinions between students and lecturers should be encouraged in order to continuously improve the teaching and learning processes.
Nowadays, it is assumed of many applications, companies and parts of the society to be always available online. However, according to [Times, Oct, 31 2011], 73% of the world population do not use the internet and thus aren't “online” at all. The most common reasons for not being “online” are expensive personal computer equipment and high costs for data connections, especially in developing countries that comprise most of the world’s population (e.g. parts of Africa, Asia, Central and South America). However it seems that these countries are leap-frogging the “PC and landline” age and moving directly to the “mobile” age. Decreasing prices for smart phones with internet connectivity and PC-like operating systems make it more affordable for these parts of the world population to join the “always-online” community. Storing learning content in a way accessible to everyone, including mobile and smart phones, seems therefore to be beneficial. This way, learning content can be accessed by personal computers as well as by mobile and smart phones and thus be accessible for a big range of devices and users. A new trend in the Internet technologies is to go to “the cloud”. This paper discusses the changes, challenges and risks of storing learning content in the “cloud”. The experiences were gathered during the evaluation of the necessary changes in order to make our solutions and systems “cloud-ready”.
The industry of the agave-derived bacanora, in the northern Mexican state of Sonora, has been growing substantially in recent years. However, this higher demand still lies under the influences of a variety of social, legal, cultural, ecological and economic elements. The governmental institutions of the state have tried to encourage a sustainable development and certain levels of standardization in the production of bacanora by applying different economical and legal strategies. However, a large portion of this alcoholic beverage is still produced in a traditional and rudimentary fashion. Beyond the quality of the beverage, the lack of proper control, by using adequate instrumental methods, might represent a health risk, as in several cases traditional-distilled beverages can contain elevated levels of harmful materials. The present article describes the qualitative spectral analysis of samples of the traditional-produced distilled beverage bacanora in the range from 0 cm−1 to 3500 cm−1 by using a Fourier Transform Raman spectrometer. This particular technique has not been previously explored for the analysis of bacanora, as in the case of other beverages, including tequila. The proposed instrumental arrangement for the spectral analysis has been built by combining conventional hardware parts (Michelson interferometer, photo-diodes, visible laser, etc.) and a set of self-developed evaluation algorithms. The resulting spectral information has been compared to those of pure samples of ethanol and to the spectra from different samples of the alcoholic beverage tequila. The proposed instrumental arrangement can be used the analysis of bacanora.
The combination of fossil-derived fuels with ethanol and methanol has acquired relevance and attention in several countries in recent years. This trend is strongly affected by market prices, constant geopolitical events, new sustainability policies, new laws and regulations, etc. Besides bio-fuels these materials also include different additives as anti-shock agents and as octane enhancer. Some of the chemical compounds in these additives may have harmful properties for both environment and public health (besides the inherent properties, like volatility). We present detailed Raman spectral information from toluene (C7H8) and ethanol (C2H6O) contained in samples of ElO gasoline-ethanol blends. The spectral information has been extracted by using a robust, high resolution Fourier-Transform Raman spectrometer (FT-Raman) prototype. This spectral information has been also compared with Raman spectra from pure additives and with standard Raman lines in order to validate its accuracy in frequency. The spectral information is presented in the range of 0 cm-1 to 3500 cm-1 with a resolution of 1.66cm-1. This allows resolving tight adjacent Raman lines like the ones observed around 1003cm-1 and 1030cm-1 (characteristic lines of toluene). The Raman spectra obtained show a reduced frequency deviation when compared to standard Raman spectra from different calibration materials. The FT-Raman spectrometer prototype used for the analysis consist basically of a Michelson interferometer and a self-designed photon counter cooled down on a Peltier element arrangement. The light coupling is achieved with conventional62.5/125μm multi-mode fibers. This FT-Raman setup is able to extract high resolution and frequency precise Raman spectra from the additives in the fuels analyzed. The proposed prototype has no additional complex hardware components or costly software modules. The mechanical and thermal disturbances affecting the FT-Raman system are mathematically compensated by accurately extracting the optical path information of the Michelson interferometer. This is accomplished by generating an additional interference pattern with a λ = 632.8 nm Helium-Neon laser (HeNe laser). It enables the FT-Raman system to perform reliable and clean spectral measurements from the materials under observation.
Monitoring of the molecular structure of lubricant oil using a FT-Raman spectrometer prototype
(2014)
The determination of the physical state of the lubricant materials in complex mechanical systems is highly critical from different points of view: operative, economical, environmental, etc. Furthermore, there are several parameters that a lubricant oil must meet for a proper performance inside a machine. The monitoring of these lubricants can represent a serious issue depending on the analytical approach applied. The molecular change of aging lubricant oils have been analyzed using an all-standard-components and self-designed FT-Raman spectrometer. This analytical tool allows the direct and clean study of the vibrational changes in the molecular structure of the oils without having direct contact with the samples and without extracting the sample from the machine in operation. The FT-Raman spectrometer prototype used in the analysis of the oil samples consist of a Michelson interferometer and a self-designed photon counter cooled down on a Peltier element arrangement. The light coupling has been accomplished by using a conventional 62.5/125μm multi-mode fiber coupler. The FT-Raman arrangement has been able to extract high resolution and frequency precise Raman spectra, comparable to those obtained with commercial FT-Raman systems, from the lubricant oil samples analyzed. The spectral information has helped to determine certain molecular changes in the initial phases of wearing of the oil samples. The proposed instrument prototype has no additional complex hardware components or costly software modules. The mechanical and thermal irregularities influencing the FT-Raman spectrometer have been removed mathematically by accurately evaluating the optical path difference of the Michelson interferometer. This has been achieved by producing an additional interference pattern signal with a λ= 632.8 nm helium-neon laser, which differs from the conventional zero-crossing sampling (also known as Connes advantage) commonly used by FT-devices. It enables the FT-Raman system to perform reliable and clean spectral measurements from the analyzed oil samples.
We report the use of the Raman spectral information of the chemical compound toluene C7H8 as a reference on the analysis of laboratory-prepared and commercially acquired gasoline-ethanol blends. The rate behavior of the characteristic Raman lines of toluene and gasoline has enabled the approximated quantification of this additive in commercial gasoline-ethanol mixtures. This rate behavior has been obtained from the Raman spectra of gasoline-ethanol blends with different proportions of toluene.
All these Raman spectra have been collected by using a self-designed, frequency precise and low-cost Fourier-transform Raman spectrometer (FT-Raman spectrometer) prototype. This FT-Raman prototype has helped to accurately confirm the frequency position of the main characteristic Raman lines of toluene present on the different gasoline-ethanol samples analyzed at smaller proportions than those commonly found in commercial gasoline-ethanol blends. The frequency accuracy validation has been performed by analyzing the same set of toluene samples with two additional state-of-the-art commercial FT-Raman devices. Additionally, the spectral information has been contrasted, with highly-correlated coefficients as a result, with the values of the standard Raman spectrum of toluene.