The conversion of space heating for private households to climate-neutral energy sources is an essential component of the energy transition, as this sector as of 2018 was responsible for 9.4 % of Germany’s carbon dioxide emissions. In addition to reducing demand through better insulation, the use of heat pumps fed with electricity from renewable energy sources, such as on-site photovoltaics (PV) systems, is an important solution approach.
Advanced energy management and control can help to make optimal use of such heating systems. Optimal here can e.g. refer to maximizing self-consumption of self-generated PV power, extended component lifetime or a grid-friendly behavior that avoids load peaks. A powerful method for this is model predictive control (MPC), which calculates optimal schedules for the controllable influence variables based on models of the system dynamics, current measurements of system states and predictions of future external influence parameters.
In this paper, we will discuss three different use cases that show how artificial intelligence can contribute to the realization of such an MPC-based energy management and control system. This will be done using the example of a real inhabited single family home that has provided the necessary data for this purpose and where the methods are implemented and tested. The heating system consists of an air-water heat pump with direct condensation, a thermal stratified storage tank, a pellet burner and a heating rod and provides both heating and hot water. The house generates a significant portion of its electricity needs through a rooftop PV system.
Solar energy plays a central role in the energy transition. Clouds generate locally large fluctuations in the generation output of photovoltaic systems, which is a major problem for energy systems such as microgrids, among others. For an optimal design of a power system, this work analyzed the variability using a spatially distributed sensor network at Stuttgart Airport. It has been shown that the spatial distribution partially reduces the variability of solar radiation. A tool was also developed to estimate the output power of photovoltaic systems using irradiation time series and assumptions about the photovoltaic sites. For days with high fluctuations of the estimated photovoltaic power, different energy system scenarios were investigated. It was found the approach can be used to have a more realistic representation of aggregated PV power taking spatial smoothing into account and that the resulting PV power generation profiles provide a good basis for energy system design considerations like battery sizing.
One of the major challenges impeding the energy transition is the intermittency of solar and wind electricity generation due to their dependency on weather changes. The demand-side energy flexibility contributes considerably to mitigate the energy supply/demand imbalances resulting from external influences such as the weather. As one of the largest electricity consumers, the industrial enterprises present a high demand-side flexibility potential from their production processes and on-site energy assets. In this direction, methods are needed with a focus on enabling the energy flexibility and ensure an active participation of such enterprises in the electricity markets especially with variable prices of electricity. This paper presents a generic model library for an industrial enterprise implemented with optimal control for energy flexibility purposes. The components in the model library represent the typical technical units of an industrial enterprise on material, media, and energy flow levels with their operative constraints. A case study of a plastic manufacturing plant using the generic model library is also presented, in which the results of two simulation with different electricity prices are compared and the behavior of the model can be assessed. The results show that the model provides an optimal scheduling of the manufacturing system according to the variations in the electricity prices, and ensures an optimal control for utilities and energy systems needed for the production.
This paper focuses on appropriately measuring the accuracy of forecasts of load behavior and renewable generation in micro-grid operation. Common accuracy measures like the root mean square of the error are often difficult to interpret for system design, as they describe the mean accuracy of the forecast. Micro-grid systems, however, have to be designed to handle also worst case situations. This paper therefore suggests two error measures that are based on the maximum function and that better allow understanding worst case requirements with respect to balancing power and balancing energy supply.
With increasing flexible AC transmission system (FACTS) devices in operation, like the most versatile unified power flow controller (UPFC), the AC/DC transmission flexibility and power system stability have been suffering unprecedented challenge. This paper introduces the user-defined modeling (UDM) method into the UPFC dynamic modeling process, to deal with the challenging requirements of power system operation. This has also been verified using a leading-edge stability analysis software named DSATools TM in the IEEE-39 bus benchmark system. The characteristics of steady-state and dynamic responses are compared and analyzed under different conditions. Furthermore, simulation results prove the feasibility and effectiveness of the proposed UPFC in terms of both the independent regulation of power flow and the improvement of transient stability.
An energy oriented design concept was developed within the research project PHOTOPUR which has the development of a PV powered water cleaning system as main focus. During a wine season Plant Protection Products (PPP) are several times sprayed on plants to protect them of undesired insects and herbs or avoid hazardous fungus
types. A work package of the project partner INES in Offenburg led to a design introducing energy profiling already in the early beginning of a product design. The concept is based on three pillars respecting first the
requirements of the core process making up filtering and cleaning and secondary aspects which run, support, maintain and monitor the system to secure availability and product reliability.
The presented paper shows that the results of the design tools guided the developers to assemble a functional model of the water decontamination unit which was manually tested with its concatenated steps of the water cleaning process.
The twin concept is increasingly used for optimization tasks in the context of Industry 4.0 and digitization. The twin concept can also help small and medium-sized enterprises (SME) to exploit their energy flexibility potential and to achieve added value by appropriate energy marketing. At the same time, this use of flexibility helps to realize a climate-neutral energy supply with high shares of renewable energies. The digital twin reflects real production, power flows and market influences as a computer model, which makes it possible to simulate and optimize on-site interventions and interactions with the energy market without disturbing the real production processes. This paper describes the development of a generic model library that maps flexibility-relevant components and processes of SME, thus simplifying the creation of a digital twin. The paper also includes the development of an experimental twin consisting of SME hardware components and a PLC-based SCADA system. The experimental twin provides a laboratory environment in which the digital twin can be tested, further developed and demonstrated on a laboratory scale. Concrete implementations of such a digital twin and experimental twin are described as examples.