Refine
Document Type
Conference Type
- Konferenzartikel (13)
- Konferenz-Abstract (1)
- Konferenz-Poster (1)
- Sonstiges (1)
Language
- English (16) (remove)
Has Fulltext
- no (16)
Is part of the Bibliography
- yes (16)
Keywords
Institute
Open Access
- Closed Access (11)
- Open Access (4)
- Closed (1)
Our university carries out various research projects. Among others, the project Schluckspecht is an interdisciplinary work on different ultra-efficient car concepts for international contests. Besides the engineering work, one part of the project deals with real-time data visualization. In order to increase the efficiency of the vehicle, an online monitoring of the runtime parameters is necessary. The driving parameters of the vehicle are transmitted to a processing station via a wireless network connection. We plan to use an augmented reality (AR) application to visualize different data on top of the view of the real car. By utilizing a mobile Android or iOS device a user can interactively view various real-time and statistical data. The car and its components are meant to be augmented by various additional information, whereby that information should appear at the correct position of the components. An engine e.g. could show the current rpm and consumption values. A battery on the other hand could show the current charge level. The goal of this paper is to evaluate different possible approaches, their suitability and to expand our application to other projects at our university.
The Raman spectra from the chemical compounds toluene and cyclohexane obtained using a Fourier Transform (FT)-Raman spectrometer prototype have been contrasted with the Raman spectra of these same materials collected with two different commercial FT-Raman devices. The FT-Raman spectrometer consist of a Michelson interferometer, a self-designed photon counter and a reference photo-detector. The evaluation methodology of the spectral information, contrary to the commercial devices that commonly use the zero-crossing method, is carried out by re-sampling the Raman scattering and by accurately extracting the optical path information of the Michelson interferometer. The FTRaman arrangement has been built using conventional parts without disregarding the spectral frequency precision that usually such a FTRaman instruments deliver. No additional complex hardware components or costly software modules have been included in this FT-Raman device. The main Raman lines from the spectra obtained with the three FT-Raman devices have been compared with the Raman lines from the standard Raman spectra of these two materials. The values obtained using the FT-Raman spectrometer prototype have shown a frequency accuracy comparable to that obtained with the commercial devices without facing the need for a large investment. Although the proposed FT-Raman prototype cannot be directly compared to the last generation of FT-Raman spectrometers from the commercial manufacturers, such a device could give an opportunity to users that require high frequency precision in their spectral analysis and are provided with rather scarce resources.
Monitoring of the molecular structure of lubricant oil using a FT-Raman spectrometer prototype
(2014)
The determination of the physical state of the lubricant materials in complex mechanical systems is highly critical from different points of view: operative, economical, environmental, etc. Furthermore, there are several parameters that a lubricant oil must meet for a proper performance inside a machine. The monitoring of these lubricants can represent a serious issue depending on the analytical approach applied. The molecular change of aging lubricant oils have been analyzed using an all-standard-components and self-designed FT-Raman spectrometer. This analytical tool allows the direct and clean study of the vibrational changes in the molecular structure of the oils without having direct contact with the samples and without extracting the sample from the machine in operation. The FT-Raman spectrometer prototype used in the analysis of the oil samples consist of a Michelson interferometer and a self-designed photon counter cooled down on a Peltier element arrangement. The light coupling has been accomplished by using a conventional 62.5/125μm multi-mode fiber coupler. The FT-Raman arrangement has been able to extract high resolution and frequency precise Raman spectra, comparable to those obtained with commercial FT-Raman systems, from the lubricant oil samples analyzed. The spectral information has helped to determine certain molecular changes in the initial phases of wearing of the oil samples. The proposed instrument prototype has no additional complex hardware components or costly software modules. The mechanical and thermal irregularities influencing the FT-Raman spectrometer have been removed mathematically by accurately evaluating the optical path difference of the Michelson interferometer. This has been achieved by producing an additional interference pattern signal with a λ= 632.8 nm helium-neon laser, which differs from the conventional zero-crossing sampling (also known as Connes advantage) commonly used by FT-devices. It enables the FT-Raman system to perform reliable and clean spectral measurements from the analyzed oil samples.
The combination of fossil-derived fuels with ethanol and methanol has acquired relevance and attention in several countries in recent years. This trend is strongly affected by market prices, constant geopolitical events, new sustainability policies, new laws and regulations, etc. Besides bio-fuels these materials also include different additives as anti-shock agents and as octane enhancer. Some of the chemical compounds in these additives may have harmful properties for both environment and public health (besides the inherent properties, like volatility). We present detailed Raman spectral information from toluene (C7H8) and ethanol (C2H6O) contained in samples of ElO gasoline-ethanol blends. The spectral information has been extracted by using a robust, high resolution Fourier-Transform Raman spectrometer (FT-Raman) prototype. This spectral information has been also compared with Raman spectra from pure additives and with standard Raman lines in order to validate its accuracy in frequency. The spectral information is presented in the range of 0 cm-1 to 3500 cm-1 with a resolution of 1.66cm-1. This allows resolving tight adjacent Raman lines like the ones observed around 1003cm-1 and 1030cm-1 (characteristic lines of toluene). The Raman spectra obtained show a reduced frequency deviation when compared to standard Raman spectra from different calibration materials. The FT-Raman spectrometer prototype used for the analysis consist basically of a Michelson interferometer and a self-designed photon counter cooled down on a Peltier element arrangement. The light coupling is achieved with conventional62.5/125μm multi-mode fibers. This FT-Raman setup is able to extract high resolution and frequency precise Raman spectra from the additives in the fuels analyzed. The proposed prototype has no additional complex hardware components or costly software modules. The mechanical and thermal disturbances affecting the FT-Raman system are mathematically compensated by accurately extracting the optical path information of the Michelson interferometer. This is accomplished by generating an additional interference pattern with a λ = 632.8 nm Helium-Neon laser (HeNe laser). It enables the FT-Raman system to perform reliable and clean spectral measurements from the materials under observation.
This paper explains the realization of a concept for research-oriented photonics education. Using the example of the integration of an actual PhD project, it is shown how students are familiarized with the topic of research and scientific work in the first semesters. Typical research activities are included as essential parts of the learning process. Research should be made visible and tangible for the students. The authors will present all aspects of the learning environment, their impressions and experiences with the implemented scenario, as well as first evaluation results of the students.
The authors explain a developed concept for research-oriented education in optics and photonics. It is presented which goals are to be achieved, which strategies have been developed and how these can be implemented in a blended learning scenario. The goal of our education is the best possible qualification of the students on the basis of a strong scientific and research-oriented education, which also includes the acquisition of important interdisciplinary competences. All phases of a research process are to be mapped in the learning process and offer students an insight into current research topics in optics and photonics.
Increased knowledge transfer through the integration of research projects into university teaching
(2019)
This paper describes the integration of the research project "Characterization of Color Vision using Spectroscopy and Nanotechnology: Application to Media Photonics" into an engineering course in the field of media technology. The aim is to develop the existing learning concept towards a more research-oriented teaching. Involving students in research projects as part of the learning process provides a deeper insight into current research topics and the key elements of scientific work. This makes it easier for students to recognize the importance of the acquired theoretical knowledge for the practice, which enables them to derive new insights of their own.