Optimization of energetic refurbishment roadmaps for multi-family buildings utilizing heat pumps
(2023)
A novel methodology for calculating optimized refurbishment roadmaps is developed in this paper. The aim of the roadmaps is to determine when and how should which component of the building envelope and heat generation system be refurbished to achieve the lowest net present value. The integrated optimization approach couples a particle swarm optimization algorithm with a dynamic building simulation of the building envelope and the heat supply system. Due to a free selection of implementation times and refurbishment depth, the optimization method achieves the lowest net present value and high CO2 reduction and is therefore an important contribution to achieve climate neutrality in the building stock.
The method is exemplarily applied to a multi-family house built in 1970. In comparison to a standard refurbishment roadmap, cost savings of 6–16 % and CO2 savings of 6–59 % are possible. The sensitivity of the refurbishment roadmap measures is analyzed on the basis of a parametric analysis. Robust optimization results are obtained with a mean refurbishment level of approx. 50 kWh/m2/a of the building envelope. The preferred heat generation system is a bivalent brine-heat pump system with a share of 70 % of the heat load being covered by the electric heat pump.
Am 1. Juli 2022 trafen sich im Rahmen des Abschlusskolloquiums des Projekts ACA-Modes rund 60 Teilnehmende aus Forschung, Lehre und Industrie zu einer internationalen Konferenz an der Hochschule Offenburg. Hier wurden die Projektergebnisse rund um die erfolgreiche Implementierung modellprädiktiver Regelstrategien vorgestellt, aktuelle Fragestellungen diskutiert und Entwicklungspfade hin zu einem netzdienlichen Betrieb von Energieverbundsystemen skizziert.
Heat pumps play a central role in decarbonizing the heat supply of buildings. However, in this article, implementing heat pumps in existing buildings, a significant challenge is still presented due to high temperature requirements. In this article, a systematic analysis of the effects of heat source temperatures, maximum heat pump condenser temperatures, and system temperatures on the seasonal performance of heat pump (HP) systems is presented. The quantitative performance analysis encompasses over 50 heat pumps installed in residential buildings, revealing correlations between the building characteristics, observed temperatures, and heat pump type. The performance of an HP system retrofitted to a 30-dwelling multifamily building is presented in more detail. The bivalent HP system combines air and ground as heat sources and achieves a seasonal performance factor of 3.25 with a share of the gas boiler of 27% in its first year of operation. In these findings, the technical feasibility of retrofitting heat pumps is demonstrated in existing buildings and insights are provided into overcoming the challenges associated with high temperature requirements.
Wirtschaftlichkeitsbetrachtung eines smarten Energiekonzepts für ein Bestandsquartier in Karlsruhe
(2023)
Die Transformation der Energieversorgung in Bestandsgebäuden ist für die Erreichung der Klimaziele im Gebäudesektor entscheidend. In einem modellhaften Quartiersprojekt in Karlsruhe-Durlach wird ein ‚smartes Energiekonzept‘, bestehend aus Wärmepumpen, Blockheizkraftwerk und PV-Anlagen mit lokalem Strom- und Wärmenetz umgesetzt und messtechnisch begleitet. Ziel ist dabei eine CO2-effiziente und wirtschaftliche Bereitstellung von Wärme und Strom.
In dem Artikel wird eine Wirtschaftlichkeitsbetrachtung für das Wärme- und Stromcontracting auf Basis der realen Investitionskosten sowie der gemessenen und berechneten Energieflüsse durchgeführt. Die Wärmegestehungskosten hängen neben den Investitionskosten von den energiewirtschaftlichen Rahmenbedingungen ab. Mit ansteigender CO2-Steuer werden mittelfristig Wärmegestehungskosten erreicht, die unter denen konventioneller Energiesysteme liegen. Dadurch bietet das integrierte Energiekonzept ein breites Anwendungspotenzial für städtische Bestandsquartiere außerhalb von Fernwärme-Gebieten.
Der prozentuale Energieaufwand für die Warmwasserbereitung ist umso höher, je geringer der Bedarf an Raumwärme – erreicht durch besser gedämmte Gebäudehüllen – ist. Gleichzeitig kann dieser Aufwand für Warmwasser aufgrund der normativ geforderten Systemtemperaturen von 60/55 °C bei zentraler Warmwasserbereitung über Wärmepumpen nur vergleichsweise energieaufwendig abgedeckt werden. Eine Studie des Fraunhofer ISE zeigt, wie groß dieser Temperatur-Effekt im Vergleich unterschiedlicher Trinkwasser-Erwärmungssysteme ist.