Refine
Year of publication
Document Type
- Conference Proceeding (286)
- Article (reviewed) (285)
- Article (unreviewed) (97)
- Part of a Book (77)
- Contribution to a Periodical (74)
- Report (44)
- Patent (38)
- Book (34)
- Doctoral Thesis (5)
- Working Paper (2)
Conference Type
- Konferenzartikel (205)
- Konferenz-Abstract (47)
- Konferenz-Poster (16)
- Sonstiges (14)
- Konferenzband (7)
Language
- English (562)
- German (382)
- Other language (1)
Is part of the Bibliography
- yes (945) (remove)
Keywords
- Dünnschichtchromatographie (28)
- Energieversorgung (14)
- Plastizität (13)
- Adsorption (11)
- Finite-Elemente-Methode (11)
- TRIZ (11)
- Materialermüdung (10)
- injury (10)
- Ermüdung (9)
- Geothermie (9)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (945) (remove)
Open Access
- Open Access (400)
- Closed Access (269)
- Closed (138)
- Bronze (88)
- Gold (34)
- Hybrid (32)
- Diamond (25)
- Grün (5)
In a randomized controlled cross-over study ten male runners (26.7 ± 4.9 years; recent 5-km time: 18:37 ± 1:07 min:s) performed an incremental treadmill test (ITT) and a 3-km time trial (3-km TT) on a treadmill while wearing either carbon fiber insoles with downwards curvature or insoles made of butyl rubber (control condition) in light road racing shoes (Saucony Fastwitch 9). Oxygen uptake, respiratory exchange ratio, heart rate, blood lactate concentration, stride frequency, stride length and time to exhaustion were assessed during ITT. After ITT, all runners rated their perceived exertion, perceived shoe comfort and perceived shoe performance. Running time, heart rate, blood lactate levels, stride frequency and stride length were recorded during, and shoe comfort and shoe performance after, the 3-km TT. All parameters obtained during or after the ITT did not differ between the two conditions [range: p = 0.188 to 0.948 (alpha value: 0.05); Cohen's d = 0.021 to 0.479] despite the rating of shoe comfort showing better scores for the control insoles (p = 0.001; d = −1.646). All parameters during and after the 3-km TT showed no differences (p = 0.200 to 1.000; d = 0.000 to 0.501) between both conditions except for shoe comfort showing better scores for control insoles (p = 0.017; d = −0.919). Running with carbon fiber insoles with downwards curvature did not change running performance or any submaximal or maximal physiological or biomechanical parameter and perceived exertion compared to control condition. Shoe comfort is impaired while running with carbon fiber insoles. Wearing carbon fiber insoles with downwards curvature during treadmill running is not beneficial when compared to running with control insoles.
Batteries typically consist of multiple individual cells connected in series. Here we demonstrate single-cell state of charge (SOC) and state of health (SOH) diagnosis in a 24 V class lithium-ion battery. To this goal, we introduce and apply a novel, highly efficient algorithm based on a voltage-controlled model (VCM). The battery, consisting of eight single cells, is cycled over a duration of five months under a simple cycling protocol between 20 % and 100 % SOC. The cell-to-cell standard deviations obtained with the novel algorithm were 1.25 SOC-% and 1.07 SOH-% at beginning of cycling. A cell-averaged capacity loss of 9.9 % after five months cycling was observed. While the accuracy of single-cell SOC estimation was limited (probably owed to the flat voltage characteristics of the lithium iron phosphate, LFP, chemistry investigated here), single-cell SOH estimation showed a high accuracy (2.09 SOH-% mean absolute error compared to laboratory reference tests). Because the algorithm does not require observers, filters, or neural networks, it is computationally very efficient (three seconds analysis time for the complete data set consisting of eight cells with approx. 780.000 measurement points per cell).
Weg- und Winkelsensoren
(2014)
Weg- und Winkelaufnehmer werden überall dort benötigt wo veränderliche Positionen, (Abstände, Längen oder Winkel) erfasst werden müssen, um entweder als reiner Messwert ausgegeben zu werden oder in einem Regelkreis zumeist die Regelgröße als Messwert zur Verfügung zu stellen. Grundsätzlich unterscheidet man zwischen berührenden (tastenden) und berührungslosen Aufnehmern. Zu den berührenden Sensoren zählen dabei alle Aufnehmer, die ein spezielles Messobjekt als Weg- oder Winkelvermittler benötigen, das während der Messung fest mit dem eigentlichen Messobjekt verbunden ist. Diese Bezeichnung gilt auch dann, wenn die eigentliche Messung gegen das vermittelnde Objekt im Endeffekt berührungslos erfolgt. Berührungslose Weg- und Winkelaufnehmer können ohne einen solchen Vermittler direkt gegen das zu vermessende Objekt messen.
Previous studies of the hyphenation of gas chromatographic separation and spectrophotometric detection in the ultraviolet wavelength range between 168 and 330 nm showed a high potential for applications where the analysis of complex samples is required. Within this paper the development of a state-of-the-art detection system for compounds in the vapour phase is described, offering an improved behaviour compared to previous systems: Dependent on the requirements of established detection systems hyphenated with gas chromatography, the main components of the system have to be designed for optimum performance and reliability of the spectrophotometric detector: A deuterium lamp as a broadband light source has been selected for improved stability in the measurements. A new-type absorption cell based on fiber-optics has been developed considering the dynamic necessary to compete with existing techniques. In addition, the influence of the volume of the cell on the chromatogram needs to be analyzed. Tests for determining the performance of the absorption cell in terms of chemical and thermal influences have been carried out. A new spectrophotometer with adequate spectral resolution in the wavelength range, offering improved stability and dynamic for an efficient use in this application was developed. Furthermore, the influence of each component on the performance, reliability and stability of the sensor system will be discussed. An overview and outlook over the potential applications in the environmental, scientific and medical field will be given.
In thin-layer chromatography, fiber-bundle arrays have been introduced for spectral absorption measurements in the UV-region. Using all-silica fiber bundles, the exciting light will be detected after re-emission on the plate with a fiberoptic spectrometer. In addition, fluorescence light can be detected which will be masked by the re-emitted light. Therefore, it is helpful to separate the absorption and fluorescence on the TLC-plate. A modified three-array assembly has been developed: using one array for detection, the two others are used for excitation with broadband band deuterium-light and with UV-LEDs adjusted to the substances under test. As an example, the quantification of glucosamine in nutritional supplements or spinach leaf extract will be described. Using simply heating of the amino-plate for derivation, the reaction product of Glucosamine can be detected sensitively either by light absorption or by fluorescence, using the new fiber-optic assembly. In addition, the properties of the new 3-row fiber-optic array and the commercially available UV-LEDs will be shown, in the interesting wavelength region for excitation of fluorescence, from 260 nm to 360 nm. The squint angle having an influence on coupling efficiency and spatial resolution will be measured with the inverse farfield method. Some properties of UV-LEDs for analytical applications will be described and discussed, too.
A wet-chemical treatment system for electrochemically coating flat substrates with coating material, has having a basin for receiving an electrolyte, a transporting means, by means of which the flat substrates can be transported through the electrolyte horizontally, and at least one contact element which comprises a shaft having an axis of rotation and a cylindrical circumferential surface suitable for rolling on the substrate, wherein the circumferential surface comprises at least one electrically insulated segment and at least one electrically conductive segment which can be connected to a current source in such a way that the polarity can be reversed, wherein the axis of rotation of the contact element is positioned above the surface of the electrolyte, and wherein the contact element is designed as a consumable electrode.
본 발명은 기판들을 금속화하기 위한 디바이스에 관한 것이다. 특별히, 본 발명은 습식-화학물질 연속 (인-라인) 처리 시스템 환경에서 솔라 셀들을 전기도금하기 위해 사용되는 컨택 엘리먼트(contact element)들의 분야에 관한 것이다. 코팅 재료로 평평한 기판들(1)들을 전기화학적으로 코팅하기 위한 본 발명에 따른 습식-화학물질 처리 시스템은 전해질 용액, 이송 수단들 - 이송 수단들을 이용하여 평평한 기판(1)이 전해질 용액을 통과하여 수평으로 이송될 수 있는 - 을 수용하는 용기(basin), 및 회전축(5)을 갖는 샤프트(4) 및 기판(1) 위에서 구르기에 적합한 원통형의 원주 표면을 포함하는 적어도 하나의 컨택 엘리먼트(2)를 가지며, 원주 표면은 극성이 역전될 수 있는 방식으로 전류 소스 (6)에 연결될 수 있는 적어도 하나의 전기적으로 전도성인 세그먼트 (3A) 및 적어도 하나의 전기적으로 절연된 세그먼트 (3B)를 포함하고, 컨택 엘리먼트 (2)의 회전축 (5)은 전해질 용액의 표면 위에 위치되고, 컨택 엘리먼트 (2)는 소모 전극(consumable electrode)으로 디자인된다.
The invention relates to a device for metalising substrates. In particular, the invention relates to the field of contact elements used to electroplate solar cells within the context of a wet-chemical continuous treatment system. A wet-chemical treatment system according to the invention, for electrochemically coating flat substrates (1) with coating material, has a tank for accommodating an electrolyte, transporting means, by means of which the flat substrates (1) can be transported through the electrolyte horizontally, and at least one contact element (2), which comprises a shaft (4) having an axis of rotation (5) and a cylindrical circumferential surface suitable for rolling on the substrate (1), wherein the circumferential surface comprises at least one electrically insulating segment (3B) and at least one electrically conductive segment (3A), which can be connected to a current source (6) in such a way that the polarity can be reversed, wherein the axis of rotation (5) of the contact element (2) is positioned above the surface of the electrolyte, and wherein the contact element (2) is designed as a consumable electrode.
Nasschemische Behandlungsanlage zum elektrochemischen Beschichten von flachen Substraten (1) mit Beschichtungsmaterial, mit einem Becken zur Aufnahme eines Elektrolyten, und mit Transportmitteln, mit welchen die flachen Substrate (1) horizontal durch den Elektrolyten transportierbar sind, sowie mit mindestens einem Kontaktelement (2), welches eine Welle (4) mit Drehachse (5) und eine zum Abrollen auf dem Substrat (1) geeignete zylindrische Umfangsfläche aufweist, wobei die Umfangsfläche mindestens ein elektrisch isoliertes Segment (3B) und mindestens ein elektrisch leitendes Segment (3A) umfasst, das mit einer Stromquelle (6) umpolbar verbindbar ist, wobei die Drehachse (5) des Kontaktelements (2) oberhalb der Oberfläche des Elektrolyten positioniert ist, und wobei das Kontaktelement (2) als Verbrauchselektrode ausgestaltet ist.
Die Erfindung betrifft eine Vorrichtung zum Metallisieren von Substraten. Insbesondere betrifft die Erfindung das Gebiet der zur Galvanisierung von Solarzellen verwendeten Kontaktelemente im Rahmen einer nasschemischen Durchlauf-Behandlungsanlage. Eine erfindungsgemäße nasschemische Behandlungsanlage zum elektrochemischen Beschichten von flachen Substraten (1) mit Beschichtungsmaterial hat ein Becken zur Aufnahme eines Elektrolyten, sowie Transportmittel, mit welchen die flachen Substrate (1) horizontal durch den Elektrolyten transportierbar sind, und mindestens ein Kontaktelement (2), welches eine Welle (4) mit Drehachse (5) und eine zum Abrollen auf dem Substrat (1) geeignete zylindrische Umfangsfläche aufweist, wobei die Umfangsfläche mindestens ein elektrisch isoliertes Segment (3B) und mindestens ein elektrisch leitendes Segment (3A) umfasst, das mit einer Stromquelle (6) umpolbar verbindbar ist, wobei die Drehachse (5) des Kontaktelements (2) oberhalb der Oberfläche des Elektrolyten positioniert ist.
Die Erfindung betrifft das Gebiet des Transports flacher Substrate wie beispielsweise Siliziumsubstrate. Insbesondere betrifft die Erfindung den besonders schonenden und kontinuierlichen Transport solcher Substrate. Das erfindungsgemäße Verfahren dient dem Transport eines vertikal ausgerichteten flachen Substrats (1) in eine Transportrichtung innerhalb eines mit einem flüssigen Medium (F) gefüllten Transportkanals (2), wobei das flüssige Medium (F) gegen mindestens eine der Flachseiten des Substrats (1) strömt und eine die Summe aus Gewichts- und Auftriebskraft des Substrats (1) aufhebende Tragekomponente, sowie eine in Transportrichtung gerichtete Vorschubkomponente aufweist, so dass das Substrat (1) ohne mechanische Hilfsmittel getragen und transportiert wird. Die erfindungsgemäße Vorrichtung umfasst einen Transportkanal (2) zur Aufnahme eines flüssiges Mediums (F) sowie eines innerhalb dieses Mediums (F) in vertikaler Ausrichtung zu führenden Substrats (1), wobei der Transportkanal (2) in seinem Wandbereich (3, 4) Einströmöffnungen (5) aufweist.
Die Erfindung betrifft das Gebiet des Transports flacher Substrate wie beispielsweise Siliziumsubstrate. Insbesondere betrifft die Erfindung den besonders schonenden und kontinuierlichen Transport solcher Substrate. Das erfindungsgemäße Verfahren dient dem Transport eines vertikal ausgerichteten flachen Substrats (1) in eine Transportrichtung innerhalb eines mit einem flüssigen Medium (F) gefüllten Transportkanals (2), wobei das flüssige Medium (F) gegen mindestens eine der Flachseiten des Substrats (1) strömt und eine die Summe aus Gewichts- und Auftriebskraft des Substrats (1) aufhebende Tragekomponente, sowie eine in Transportrichtung gerichtete Vorschubkomponente aufweist, so dass das Substrat (1) ohne mechanische Hilfsmittel getragen und transportiert wird. Die erfindungsgemäße Vorrichtung umfasst einen Transportkanal (2) zur Aufnahme eines flüssiges Mediums (F) sowie eines innerhalb dieses Mediums (F) in vertikaler Ausrichtung zu führenden Substrats (1), wobei der Transportkanal (2) in seinem Wandbereich (3, 4) Einströmöffnungen (5) aufweist.
Die Erfindung betrifft einen elektromotorischen Aktor, insbesondere für einen mobilen Roboter, mit einem geschalteten, zylindrischen Linearreluktanzmotor-Antrieb (21), bestehend aus einem hohlzylindrischen Stator (23), welcher am Innenumfang zwischen umlaufenden Statorzähnen (23a) vorgesehene umlaufende Nuten (23b) aufweist, in welchen Motorwicklungen (27a, 27b, 27c, 27’a, 27’b, 27’c) angeordnet sind, und einem innerhalb des Stators (23) koaxial vorgesehenen zylindrischen oder hohlzylindrischen Translator (25) mit am Außenumfang vorgesehenen, umlaufenden Translatorzähnen (25a), wobei der Stator (23) im Bereich der Statorzähne (23a) und der Translator (25) im Bereich der Translatorzähne (25a) aus einem ferromagnetischen Material bestehen. Erfindungsgemäß ist der Translator (25) über eine mechanische Vorrichtung zur Speicherung und Abgabe von kinetischer Energie (31) fest oder nur für einen vorbestimmten Bereich eines Bewegungsbereichs des Translators (25) mit dem Stator (25) gekoppelt.
Messschraube zur Ermittlung von Schraubenbelastungen, die einen Schraubenkopf (8) und einen Schraubenschaft (9) mit einem oberen Schaftbereich (7) aufweist, der bei bestimmungsgemäßer Benutzung der Schraube nicht an einem Objekt anliegt, wobei mindestens zwei Dehnungsmesssensoren so im Schraubenschaft (9) angeordnet und dehnungskinematisch mit dem Schraubenschaft (9) gekoppelt sind, dass sie Dehnungswerte im Schraubenschaft (9) erfassen, aus denen über konstitutive Materialgesetze Belastungen in mehr als einer Achse im oberen Schaftbereich (7) bestimmt werden können, wobei die Dehnungsmesssensoren als faseroptische Sensoren an mehreren Stellen entlang mindestens einer optischen Faser (1) ausgebildet sind.
Die vorliegende Erfindung betrifft eine Messchraube zur Ermittlung von Schraubenbelastungen sowie ein Verfahren zu deren Herstellung. Die Messschraube umfasst mindestens zwei Dehnungsmesssensoren, die so im Schraubenschaft angeordnet und dehnungskinematisch mit dem Schraubenschaft gekoppelt sind, dass sie Dehnungswerte im Schraubenschaft erfassen, aus denenüber konstitutive Materialgesetze Belastungen in mehr als einer Achse im oberen freien Schaftbereich bestimmt werden können. Durch Möglichkeit der Bestimmung mehrachsiger Belastungen lassen sich Schrauben sachgerechter auslegen, so dass die Gefahr von Schraubenbrüchen reduziert wird.
Variable refrigerant flow (VRF) and variable air volume (VAV) systems are considered among the best heating, ventilation, and air conditioning systems (HVAC) thanks to their ability to provide cooling and heating in different thermal zones of the same building. As well as their ability to recover the heat rejected from spaces requiring cooling and reuse it to heat another space. Nevertheless, at the same time, these systems are considered one of the most energy-consuming systems in the building. So, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. This study aims to compare these two energy systems by conducting an energy model simulation of a real building under a semi-arid climate for cooling and heating periods. The developed building energy model (BEM) was validated and calibrated using measured and simulated indoor air temperature and energy consumption data. The study aims to evaluate the effect of these HVAC systems on energy consumption and the indoor thermal comfort of the building. The numerical model was based on the Energy Plus simulation engine. The approach used in this paper has allowed us to reach significant quantitative energy saving along with a high level of indoor thermal comfort by using the VRF system compared to the VAV system. The findings prove that the VRF system provides 46.18% of the annual total heating energy savings and 6.14% of the annual cooling and ventilation energy savings compared to the VAV system.
During pyrolysis, biomass is carbonised in the absence of oxygen to produce biochar with heat and/or electricity as co-products making pyrolysis one of the promising negative emission technologies to reach climate goals worldwide. This paper presents a simplified representation of pyrolysis and analyses the impact of this technology on the energy system. Results show that the use of pyrolysis can allow getting zero emissions with lower costs by making changes in the unit commitment of the power plants, e.g. conventional power plants are used differently, as the emissions will be compensated by biochar. Additionally, the process of pyrolysis can enhance the flexibility of energy systems, as it shows a correlation between the electricity generated by pyrolysis and the hydrogen installation capacity, being hydrogen used less when pyrolysis appears. The results indicate that pyrolysis, which is available on the market, integrates well into the energy system with a promising potential to sequester carbon.
TRIZ Innovationstechnologie
(2023)