Evidence-based numerical building model enhancement and building energy efficiency evaluation in the case of Morocco

  • This paper presents a framework for numerical building validation enhancement based on detailed building specifications from in-situ measurements and evidence-based validation assessment undertaken on a detached sustainable lightweight building in a semi-arid climate. The validation process has been undergone in a set of controlled experiments – a free-float period, and steady-state internalThis paper presents a framework for numerical building validation enhancement based on detailed building specifications from in-situ measurements and evidence-based validation assessment undertaken on a detached sustainable lightweight building in a semi-arid climate. The validation process has been undergone in a set of controlled experiments – a free-float period, and steady-state internal temperatures. The validation was conducted for a complete year with a 1-min time step for the hourly indoor temperature and the variable refrigerant flow (VRF) energy consumption. The initial baseline model was improved by three series of validation steps per three different field measurements including thermal transmittance, glazing thermal and optical properties, and airtightness. Then, the accurate and validated model was used for building energy efficiency assessment in 12 regions of Morocco. This study aims to assess the effect of accurate building characteristics values on the numerical model enhancement. The initial CV(RMSE) and NMBE have improved respectively from 14.58 % and −11.23 %–7.85 % and 1.86 % for the indoor temperature. Besides, from 31.17 % to 14.37 %–20.57 % and 9.77 % for energy consumption. The findings demonstrate that the lightweight construction with the use of a variable refrigerant flow system could be energy efficient in the southern regions of Morocco.show moreshow less

Download full text files

Export metadata

Statistics

frontdoor_oas
Metadaten
Document Type:Article (reviewed)
Zitierlink: https://opus.hs-offenburg.de/7967
Bibliografische Angaben
Title (English):Evidence-based numerical building model enhancement and building energy efficiency evaluation in the case of Morocco
Author:Niima Es-sakali, Samir Idrissi Kaitouni, Imad Ait Laasri, Mohamed Oualid Mghazli, Moha Cherkaoui, Moritz BühlerStaff Member, Jens PfafferottStaff MemberORCiDGND
Year of Publication:2023
Publisher:Elsevier
First Page:1
Last Page:23
Article Number:103606
Parent Title (English):Case Studies in Thermal Engineering
Volume:51
ISSN:2214-157X
DOI:https://doi.org/10.1016/j.csite.2023.103606
URN:https://urn:nbn:de:bsz:ofb1-opus4-79671
Language:English
Inhaltliche Informationen
Institutes:Forschung / INES - Institut für nachhaltige Energiesysteme
Fakultät Maschinenbau und Verfahrenstechnik (M+V)
Institutes:Bibliografie
DDC classes:600 Technik, Medizin, angewandte Wissenschaften
Tag:Building energy model; Energy simulation; Light-weight building; Variable refrigerant flow system
Funded by (textarea):DAAD
Formale Angaben
Relevance:Wiss. Zeitschriftenartikel reviewed: Listung in Master Journal List
Open Access: Open Access 
 Gold 
Licence (German):License LogoCreative Commons - CC BY - Namensnennung 4.0 International