Significance of new electrocardiographic parameters to improve cardiac resynchronization therapy

  • Introduction: Oesophageal left heart electrogram (LHE) is a valuable tool providing electrocardiographic parameters for cardiac resynchronization therapy (CRT). It can be utilized to measure left ventricular (LVCD) and intra-leftventricular conduction delays (ILVCD) in heart failure patients to justify implantation of CRT systems. In the follow-up, LHE enables measurement of implant-relatedIntroduction: Oesophageal left heart electrogram (LHE) is a valuable tool providing electrocardiographic parameters for cardiac resynchronization therapy (CRT). It can be utilized to measure left ventricular (LVCD) and intra-leftventricular conduction delays (ILVCD) in heart failure patients to justify implantation of CRT systems. In the follow-up, LHE enables measurement of implant-related interatrial conduction times (IACT) which are the key intervals defining the hemodynamically optimal AV delay (AVD). Methods: By TOSlim oesophageal electrode and Rostockfilter (Osypka AG, Rheinfelden, Germany), LHE was recorded in 39 heart failure patients (10f, 29m, 65±8yrs., QRS=163±21ms) after implantation of CRT systems according to guidelines. In position of maximal left ventricular deflection, LVCD and ILVCD were measured and compared with QRS width. In position of maximal left atrial deflection (LA), IACT was determined in VDD and DDD operation as interval As-LA and Ap-LA between atrial sense event (As) or stimulus (Ap), resp., and onset of LA. AVD was individualized using SAV =As-LA + 50ms for VDD and PAV=Ap-LA + 50ms for DDD operation. Results: The CRT patients were characterized by minimal transoesophageal LVCD of 40ms but 73±20ms, at mean, ILVCD of 90±24ms and QRS/LVCD ratio of 2.4±0.6. The measured As-LA of 39±24ms and Ap-LA of 124±26ms resulted into SAV of 89±24ms and PAV of 174±26ms. In case of empirical AVD programming using 120ms for SAV and 180ms for PAV, the LHE revealed inverse sequences of LA and Vp in 4 patients (10%) during VDD and 13 patients (33%) in DDD pacing. In these patients, Vp preceded LA as IACT exceeded the programmed AVD. Conclusion: Guideline indication of CRT systems is associated with LVCD of 40ms or more. Therefore, individual LVCD offers the minimal target interval that should be reached during left ventricular electrode placement to increase responder rate. Postoperatively, AV delay optimization respecting implant-related IACTs excludes adverse hemodynamic effects.show moreshow less

Export metadata

Additional Services

Search Google Scholar

Statistics

frontdoor_oas
Metadaten
Document Type:Conference Proceeding
Conference Type:Konferenz-Abstract
Zitierlink: https://opus.hs-offenburg.de/738
Bibliografische Angaben
Title (English):Significance of new electrocardiographic parameters to improve cardiac resynchronization therapy
Conference:BMT 2011: Conference of the German Society for Biomedical Engineering / DGBMT Jahrestagung (45. : 27.-30. September 2011 : Freiburg, Deutschland)
Author:Bruno IsmerStaff MemberGND, Frank Kleimenhagen, Matthias HeinkeStaff MemberORCiDGND, Lena Rösch, Kirsten-Maria Rotter, Christoph Melzer, Frank Weber
Date of Publication (online):2011/09/30
Place of publication:Berlin, Boston
Publisher:Walter de Gruyter
Page Number:1
First Page:3
Parent Title (Multiple languages):Biomedical Engineering / Biomedizinische Technik
Volume:56
Issue:S1
ISSN:0013-5585 (Print)
ISSN:1862-278X (Online)
DOI:https://doi.org/10.1515/bmt.2011.850
Language:English
Inhaltliche Informationen
Institutes:Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019)
Institutes:Bibliografie
Formale Angaben
Open Access: Closed Access 
Licence (German):License LogoUrheberrechtlich geschützt